Construindo confiança, garantindo o sucesso Meu portal dang.victor@worldsteelgroup.com +84 902 881 833
World SteelBuilding trust, Assuring success
Structural analysis model of a steel portal-frame building coloured by member utilisation

Solution · Design & engineering

Design & engineering – safe, code-compliant and optimised steel

In-house structural engineers and detailers turn your architecture and brief into an optimised steel structure: design basis, analysis and member design to the code of your market, connection design, design report and column reactions – then the 3D model, shop and erection drawings that carry the design to the factory and the site.

Request a quotationConheça a solução

In-house
Engineers & detailers
design to drawings, one team
4 code families
US · AU/NZ · EU · VN
designed to your market
Optimised
Steel weight
tapered and built-up members
6 steps
Design workflow
PPD to as-built
Analysis model with utilisation colours

Engineering is where the value is decided

The steel price of a building is decided long before the steel is bought – by the frame type, the spans, the loads assumed, the member sizes and the connections. Our design team takes those decisions with you: safe and compliant with the code of your market, and economical in steel, fabrication and erection.

Because our engineers, detailers and factory work together, the design is made for fabrication from the start – sections we can build efficiently, connections that bolt up at site, and a single 3D model that carries the design from the calculation to the shop floor and the erection drawings.

Design services

What our engineers do

From the first load assumption to the last connection detail.

Design basis & loadscodes · climate

Design basis & loads

Codes, dead, live, wind, seismic, crane, collateral and thermal loads agreed and written down before design.

Analysis & optimisationframes · members

Analysis & optimisation

Frame analysis, member checks, deflections and stability – with sizes optimised for weight and fabrication.

Connection designbolts · plates · welds

Connection design

End-plate, splice, base-plate, bracing and crane connections designed and detailed.

Seismic & wind designspecial loads

Seismic & wind design

Seismic systems, typhoon and cyclone wind and uplift through the full load path – see seismic steel.

Foundation interfacecolumn reactions

Foundation interface

Anchor bolt plans and unfactored column reactions by load case for your foundation designer.

Design reportcalculations

Design report

Design basis, analysis, member and connection checks, deflections – ready for review and approval.

Aplicações

Why design with World Steel

01

Optimised, not oversized

Tapered and built-up members sized to the forces, frame spacing and purlin systems chosen for least weight and cost.

02

Code of your market

Design to AISC/ASCE, AS/NZS, Eurocodes or TCVN, with local loads, wind, seismic and climate data.

03

Designed for fabrication

Members and connections our factory builds efficiently and your erector assembles quickly.

04

Transparent design

Approval drawings, design report and column reactions submitted for your engineer's review.

05

One model, no gaps

Analysis, 3D model, shop and erection drawings from one team – nothing lost between consultants.

06

Certification support

Coordination with a licensed engineer where the authority requires sealed drawings.

Normas e conformidade

Design codes by market

We design to the code of the project location – with its loads, materials and documentation.

United States

  • AISC 360 · AISC 341Structural steel buildings; seismic provisions
  • ASCE 7 · IBCMinimum design loads; building code
  • AISI S100Cold-formed steel members – purlins and girts
Todas as normas United States →

Australia & New Zealand

  • AS 4100 · NZS 3404Steel structures design
  • AS/NZS 1170Structural design actions – dead, live, wind, snow, earthquake
  • AS/NZS 4600Cold-formed steel structures
Todas as normas Australia & New Zealand →

Europe

  • EN 1993-1-1 · -1-3 · -1-8Eurocode 3 – members, cold-formed, joints
  • EN 1991 · EN 1998Actions; seismic design
Todas as normas Europe →

Vietnam

  • TCVN 5575Steel structures – design standard
  • TCVN 2737:2023Loads and actions
  • QCVN 02:2022/BXDNatural, physical and climatic data for construction

Resumo apenas para orientação – prevalecem a especificação do projeto, a edição da norma adotada e a autoridade competente.

Deliverables

What our design team delivers

Each deliverable has its own page in our design workflow.

Proposal drawings (PPD)

With the quotation

Layout, sections and quantities – see PPD.

Approval drawings

After contract

General arrangement for review – see approval.

Design report

Calculations

Design basis, analysis and checks for your engineer.

Column reactions

Foundations

Unfactored reactions by load case with the anchor bolt plan.

3D Tekla model

BIM

Every member and connection – see 3D model.

Scope agreed per contract.

Optimisation

Less steel, same safety

Optimisation starts with the concept – frame type, spans and bay spacing – and continues member by member. Tapered built-up rafters and columns follow the bending moment, purlin and girt systems are chosen for the spans and loads, and bracing is placed where it works hardest. Every member is checked against the code; none is heavier than it needs to be.

Utilisation-coloured analysis model

Design workflow · step 2 of 6

Design you can check before it is built

Design runs through our six-step workflow: proposal drawings with the quotation, approval drawings, design report and column reactions after the contract, then the 3D Tekla model, shop drawings, erection drawings and as-built drawings. Nothing is fabricated before you or your engineer approve the design.

Coordination

Steel coordinated with everything else

Architecture, MEP services, cranes, equipment and foundations all meet the steel. We exchange IFC models with your design team, check clashes and agree penetrations, hangers and openings before the drawings are released – so problems are solved on screen, not on site.

Clash check between steel and services

Reference

Design phases and outputs

How design runs through the project.

Design phases
PhaseMain outputsReviewed by
Concept & proposalFrame concept, PPD, preliminary quantitiesOwner, architect
Technical designDesign basis, analysis, design report, approval drawings, column reactionsOwner's engineer, authority
Fabrication design3D model, connections, shop drawings, CNC dataWorld Steel checker, QA/QC
Erection designErection drawings, sequence, bolt lists, method supportErector, site supervisor
HandoverAs-built drawings and modelOwner

Processo

The six-step design workflow

  1. 1

    1 · Proposal drawings

    Layout, sections and quantities with the quotation.

  2. 2

    2 · Approval

    Drawings, design report and column reactions approved.

  3. 3

    3 · 3D Tekla model

    Every member, plate and bolt modelled.

  4. 4

    4 · Shop drawings

    Assembly and part drawings, CNC data.

  5. 5

    5 · Erection drawings

    Plans, sections, sequence and bolt lists.

  6. 6

    6 · As-built

    Final record with the quality dossier.

FAQ

Perguntas frequentes

Can you design from our architectural drawings?

Yes. Send us the architectural drawings or a sketch with the loads and site – we propose the structure, design it to your code and submit it for approval.

Which design codes do you use?

AISC/ASCE for the United States, AS/NZS for Australia and New Zealand, Eurocodes for Europe and TCVN for Vietnam – or the code your specification requires.

Will your engineer's design be reviewed?

Yes – the approval drawings, design report and column reactions are submitted for review by you, your engineer or the authority before fabrication.

Can you provide sealed drawings for a permit?

Where the authority requires sealed drawings or design certification, we coordinate with a licensed engineer for the project, as agreed in the contract.

Can you only design, without fabrication?

Our design service is part of the steel supply; design-only scopes are considered case by case.

Start with the design

Send us your architecture, loads and site – we reply with proposal drawings and an optimised steel solution.

Request a quotation +84 902 881 833