Construindo confiança, garantindo o sucesso Portal do cliente dang.victor@worldsteelgroup.com +84 902 881 833
World SteelBuilding trust, Assuring success
Light gauge steel framed two-storey building with wall panels and roof trusses

Solution · Light gauge steel framing

Light gauge steel framing – precise, light and fast to build

Cold-formed C studs, tracks, joists, roof trusses and battens in high-tensile G550 / G300 steel with Z275 – AZ150 coatings – supplied as members, prefabricated wall panels, floor cassettes, trusses or complete building kits, designed to AISI S100 / S240, AS/NZS 4600 and EN 1993-1-3.

Request an LGS framing quoteConheça a solução

0.75 – 2.4 mm
Steel thickness
G550 · G450 · G300
75 – 300 mm
Stud and joist webs
C, U, top-hat, box
±1 mm
CNC cut and punch
labelled to the panel
1 – 6+
Storeys
load-bearing walls
Light gauge steel load-bearing wall panel

What light gauge steel framing is

Light gauge steel (LGS) framing – also called cold-formed steel (CFS) framing – builds walls, floors and roofs from thin galvanised or zinc-aluminium coated steel strip, roll-formed into C, U and top-hat sections. Members are cut to length, punched for services and screws, and assembled with self-drilling screws into studs, joists and trusses, much like a timber frame but straight, non-combustible and immune to termites and rot.

LGS is used for houses and townhouses, schools, clinics, hotels and mid-rise apartments, for infill and partition walls in steel and concrete frames, for roof trusses over concrete buildings and for factory-built modules. World Steel supplies LGS framing together with our steel frames, floor decks and anchors and fasteners, so the whole structure is coordinated in one model.

LGS range

Light gauge steel products

Each product has its own page with sections, grades, coatings, standards and ordering data.

Where LGS is used

Typical light gauge steel projects

From a single house to the internal walls of a high-rise – the same members, designed for the job.

Houses and townhouses1 – 3 storeys

Houses and townhouses

Complete frames: walls, floors, trusses and battens.

Mid-rise apartments and hotels4 – 6+ storeys

Mid-rise apartments and hotels

Load-bearing walls on a concrete podium, or infill in a steel frame.

Schools, clinics, officeslow-rise

Schools, clinics, offices

Fast, dry construction with long spans and clean finishes.

Roof trusses over concretere-roofing

Roof trusses over concrete

Light trusses on concrete frames and for roof upgrades.

Modules and site campsoff-site

Modules and site camps

Volumetric units for housing, camps and site offices.

Aplicações

Why build with light gauge steel

01

Light

A frame several times lighter than concrete – smaller foundations and lower transport cost.

02

Precise

CNC roll-formed, cut and punched from the model – straight walls, square corners.

03

Fast

Panels and trusses arrive ready to stand – a house frame goes up in days.

04

Durable

Coated steel does not rot, warp, shrink or feed termites.

05

Non-combustible

Steel adds no fuel; fire ratings come from tested board systems.

06

Recyclable

Steel is reusable and recyclable, with little site waste.

Normas e conformidade

Design, material and construction standards

LGS members are designed as cold-formed steel; wall and floor systems are rated with tested assemblies:

Vietnam & Asia

  • AISI S100 · AS/NZS 4600 · EN 1993-1-3Used in practice for member design
  • QCVN 06:2022/BXDFire safety of buildings
  • TCVN 2737Loads and actions
  • QCVN 02:2022/BXDNatural conditions – wind and seismic

United States

  • AISI S100Cold-formed steel structural members
  • AISI S240Cold-formed steel structural framing
  • AISI S220Non-structural members
  • AISI S400Seismic design of CFS systems
  • ASTM A1003 · C955 · C645Sheet steel and framing members
Todas as normas United States →

Australia / NZ

  • AS/NZS 4600Cold-formed steel structures
  • NASH StandardResidential and low-rise steel framing
  • AS 1397Metallic-coated steel sheet – G550 / G300, Z / AZ / AM
  • NCC Volume TwoHousing provisions – steel framing via NASH
Todas as normas Australia & New Zealand →

Europe

  • EN 1993-1-3Cold-formed members and sheeting
  • EN 1090-2 · EN 1090-4Execution of steel and cold-formed structures
  • EN 10346Continuously hot-dip coated steel – S350GD – S550GD
  • EN 14195Metal framing for gypsum board systems
Todas as normas Europe →

Resumo apenas para orientação – prevalecem a especificação do projeto, a edição da norma adotada e a autoridade competente.

Engenharia

One system, from foundation to ridge

Tracks are anchored to the slab, studs carry the walls, joists and cassettes form the floors, trusses span the roof and battens carry the cladding. Strap or sheet bracing and hold-downs take wind and earthquake loads to the foundation. Every member is designed, detailed and labelled as part of the same model.

Light gauge steel building system with labelled members
Light gauge steel sections – C stud, U track, C joist, top-hat and back-to-back

Engenharia

The sections behind every frame

Lipped C sections work as studs, joists and truss chords; unlipped U tracks hold the studs at top and bottom; top-hat sections make battens; back-to-back and boxed sections carry lintels and heavy posts. Thickness and steel grade are chosen member by member, so the frame uses steel only where it is needed.

Engenharia

Walls that perform

Studs at 400 or 600 mm centres are lined with fibre-cement, gypsum or OSB boards, filled with mineral wool and finished with a weather barrier and cladding. Fire, acoustic and thermal ratings come from the tested board system, so walls are specified as complete assemblies – not just steel.

Light gauge steel wall build-up with boards and insulation
Light gauge steel compared with timber, concrete and hot-rolled steel

Engenharia

LGS compared with other systems

LGS combines the speed and dryness of a timber frame with the durability of steel and a fraction of the weight of concrete. For long spans, heavy loads and high-rise frames it works alongside hot-rolled steel and concrete rather than replacing them.

Reference data

Sections, steel and members

Typical values for orientation only. Section properties and capacities come from the profile manufacturer's tables and the design standard for the project.

Common profile sizes
MemberWeb (mm)Flange (mm)Lip (mm)Thickness (mm)Typical use
C stud75 · 89 · 92 · 10035 – 419 – 120.75 – 1.2Load-bearing walls 1 – 2 storeys, infill walls
C stud (heavy)140 · 15041 – 5012 – 151.0 – 2.0Tall walls, lower storeys of mid-rise, facades
U trackto suit stud32 – 50–0.75 – 1.6Top and bottom plates, headers
C joist150 · 200 · 250 · 30041 – 6512 – 201.0 – 2.4Floor joists, rafters, purlin-type members
Truss chord / web75 · 8935 – 419 – 120.75 – 1.2Roof trusses
Top-hat batten22 · 40 · 61 · 120 (height)––0.42 – 1.2Roof battens, ceiling and wall furring
Back-to-back / boxed2 × C or C + U––1.0 – 2.4Lintels, posts, jamb studs

Especificações

What we supply

Members
C studs, tracks, joists, trusses, battens – cut to length, punched and labelled
Prefabrication
Loose members, wall panels, floor cassettes, roof trusses, volumetric modules
Steel
G550 / G450 / G300, ST33H / ST50H, S350GD – S550GD; Z275, AZ150, ZM coatings
Engineering
Member and connection design to AISI S100 / S240, AS/NZS 4600 / NASH, EN 1993-1-3
Connections
Screws, straps, hold-downs and anchors to the slab
With the steel
Primary steel, floor decking, mezzanines, roofing and cladding in one package
Documents
BIM model, shop drawings, panel layouts, assembly manual, packing lists

Processo

How an LGS project is delivered

  1. 1

    Design

    Architecture, loads and fire / acoustic requirements.

  2. 2

    BIM model

    Every member, opening and service hole in 3D.

  3. 3

    Roll-forming

    CNC roll-formed, cut, punched and labelled.

  4. 4

    Panels

    Walls, cassettes and trusses assembled on jigs.

  5. 5

    Packing

    Bundled by floor and panel for export.

  6. 6

    Erection

    Anchored, stood, braced and checked on site.

Condições de entrega · Incoterms® 2020

Entregue nas condições que você precisa

A World Steel cota na fábrica, FOB ou entregue no seu porto ou obra. Embalagem de exportação, documentos e embarque a partir de Ho Chi Minh fazem parte do serviço.

Comparar os Incoterms® 2020 →

FAQ

Perguntas frequentes

What is light gauge steel framing (khung thép nhẹ)?

A building frame made of thin cold-formed steel sections – C studs, U tracks, joists, trusses and battens – usually 0.75 to 2.4 mm thick, screwed together into walls, floors and roofs.

How tall can an LGS building be?

Load-bearing LGS is common up to about six storeys, often on a concrete podium; higher buildings use LGS for infill walls and partitions inside a steel or concrete frame. The limit depends on loads, wind, seismic zone and local code.

Does LGS rust?

Members are protected by Z275 galvanised or AZ150 zinc-aluminium coatings and sit inside the building envelope. Heavier coatings, stainless fasteners and good detailing are used near the coast and in wet areas.

Is an LGS building fire resistant?

Steel does not burn, but thin sections lose strength in fire. Fire resistance comes from tested wall and floor assemblies – typically fire-rated gypsum or fibre-cement boards with mineral wool.

How does LGS compare with concrete for a house?

The frame is much lighter, dry and quick to erect, with precise dimensions and less waste. Concrete gives more thermal mass and is familiar to local trades; the right choice depends on site, speed and budget.

Can I order loose members or only complete kits?

Both – loose members cut and punched to a drawing, prefabricated wall panels, floor cassettes and trusses, or a complete building kit with drawings and assembly instructions.

Planning a light gauge steel project?

Send the drawings, location and number of storeys – we return the framing concept, member schedule and a supply price for members, panels or a complete kit.

Request an LGS framing quote +84 902 881 833