- Infill walls between floors of steel or concrete frames
- Facade backing for cladding and render
- Drywall partitions and shaft walls
- Slotted deflection heads
- Fire and acoustic tested systems
- Fast, light, dry construction
What it is
In framed buildings the external walls and internal partitions do not carry the floors. LGS infill walls span floor to floor, take the wind load on the facade and support the cladding; partitions divide the space. Slotted deflection tracks let the floor above move without loading the wall.
Systems
- External infill walls with studs C 92 – 150, sheathing and cladding rails
- Partitions with studs C 64 – 92 and plasterboard
- Shaft and corridor walls with fire-rated boards
- Ceilings on furring channels
Normas e requisitos por mercado
Normas segundo as quais a World Steel projeta, fabrica e documenta este produto – e os principais requisitos geométricos e de carga em cada mercado.
Estados Unidos
- ASTM C645Non-structural steel framing
- AISI S220Non-structural framing
- ASTM C754Installation of steel framing for gypsum panels
Europa
- EN 14195Metal framing for plasterboard systems
- EN 13964Suspended ceilings
Austrália / NZ
- AS/NZS 4600Cold-formed steel
- AS 2785Suspended ceilings
Resumo apenas para orientação – prevalecem a especificação do projeto, a edição da norma adotada e a autoridade competente.
Acabamentos
| Acabamento | Normas / observações |
|---|---|
| Frame | Z275 / AZ150 |