- Infill walls between floors of steel or concrete frames
- Facade backing for cladding and render
- Drywall partitions and shaft walls
- Slotted deflection heads
- Fire and acoustic tested systems
- Fast, light, dry construction
What it is
In framed buildings the external walls and internal partitions do not carry the floors. LGS infill walls span floor to floor, take the wind load on the facade and support the cladding; partitions divide the space. Slotted deflection tracks let the floor above move without loading the wall.
Systems
- External infill walls with studs C 92 – 150, sheathing and cladding rails
- Partitions with studs C 64 – 92 and plasterboard
- Shaft and corridor walls with fire-rated boards
- Ceilings on furring channels
תקנים ודרישות לפי שוק
התקנים שלפיהם World Steel מתכננת, מייצרת ומתעדת מוצר זה – ודרישות הגיאומטריה והעומס העיקריות בכל שוק.
ארצות הברית
- ASTM C645Non-structural steel framing
- AISI S220Non-structural framing
- ASTM C754Installation of steel framing for gypsum panels
אוסטרליה / ניו זילנד
- AS/NZS 4600Cold-formed steel
- AS 2785Suspended ceilings
סיכום להתמצאות בלבד – מפרט הפרויקט, מהדורת התקן שאומצה והרשות המוסמכת הם הקובעים.
גימורים
| גימור | תקנים / הערות |
|---|---|
| Frame | Z275 / AZ150 |