Construindo confiança, garantindo o sucesso Portal do cliente dang.victor@worldsteelgroup.com +84 902 881 833
World SteelBuilding trust, Assuring success

Capítulo 5 de 13 · Section 6 · Clauses 6.1–6.13 · Appendix F (link)

Preparation, assembly and fabrication under AS/NZS 5131 Section 6

How AS/NZS 5131 Section 6 controls identification, cutting, forming, holing, assembly and dispatch – and what a CC3 fabricator must prove.

Every Section 6 operation needs a written work method statement (Clause 6.1.3)At CC3 and CC4, punched holes must be subpunched 3 mm undersize and reamedHot forming capped at 620 °C; no bending in the 250–380 °C blue heat rangeFull contact bearing ends: max 1 mm gap, ≤0.5 mm over at least 67% of areaComplex interfaces must be fit-checked and documented before dispatchFrom CC2 up, a competent person supervises cutting, holing, shaping and assembly

What Section 6 covers and why assessors start here

Section 6 of AS/NZS 5131 governs everything that happens to steel between receipt and welding or bolting: identification, handling, cutting, shaping, holing and assembly into fabricated items, and finally protection for transit. Clause 6.1.1 ties all of this to the fabrication tolerances of Appendix F and requires that the facility and equipment are maintained so that wear does not cause inconsistent output. In other words, the standard expects a controlled process, not just a good final dimension check.

Two procedural requirements apply regardless of construction category. Clause 6.1.2 requires the operations to run under a suitable quality management system (see quality management under AS/NZS 5131), and Clause 6.1.3 requires a documented work method statement for each operation and each stage of work before it starts, available to the people doing the work. Steel that will be painted or galvanized must also meet Clauses 9.3 and 9.8, and AESS must meet Section 10 (Clauses 6.1.4–6.1.5).

Identification, marking, handling and customer property

Clause 6.2 requires the fabricator to keep the manufacturer's test reports and certificates for every item of steel and to run a tracking system that supports the traceability rules of Clause 5.2.3 (covered in materials and traceability). For New Zealand work at CC3 and CC4, the tracking system must also trace welders and welding procedures to individual primary connection welds, by weld map or welder ID stamp.

Marking must not damage the steel. Unless the specification says otherwise, hard stamped, punched or drilled marks are limited to grades up to GR 350, are not used on coated cold-formed material, and are kept to areas where fatigue life is unaffected. Zones where marks are prohibited – typically fatigue-loaded details or potential plastic hinge regions – should be stated in the construction specification. Any piece that cannot be clearly identified becomes unidentified steel and is dealt with under Clause 13.3.7.

Clause 6.3 asks that members, components and fasteners are handled and stacked to avoid damage or permanent deformation, with painted and galvanized items following Clauses 9.9.19 and 9.10.10. Clause 6.4 treats customer supplied property – components, but also drawings, models and data – like purchased items: identified, verified, protected, and any loss or damage reported and recorded.

Cutting: methods, cut quality and re-entrant corners

Clause 6.5.1 allows sawing, shearing, cropping, machining, thermal cutting (oxy, plasma, laser) and water cutting unless the specification excludes a process. Two restrictions matter in practice: material over 16 mm thick should not be sheared where it will be galvanized and loaded in tension (unless stress relieved), and shearing is not permitted in designated seismic yielding regions – sheared material there is cut 3 mm oversize and machined back.

Cut surfaces not incorporated in a weld must meet the roughness limits of Table 6.5, measured by the CLA method of BS 1134. For statically loaded steel the limit is 25 µm; tighter values apply to higher fatigue detail categories and to New Zealand yielding regions. Oversize roughness is ground out, with grinding marks parallel to the cut. Clause 6.5.2 also sets limits on isolated notches and gouges and on when they must be ground or weld repaired under Clause 13.6.2.5. Re-entrant corners must be notch free with a radius of at least 10 mm, normally by drilling at the corner and cutting to the hole (Clause 6.5.3). Edge condition for coating – edge rounding and surface preparation of cut and rolled edges – is referred to Clauses 9.8.4 and 9.8.5; see corrosion protection.

Shaping: hot forming, flame straightening and cold bending

Clause 6.6 permits straightening, bending, pressing and cambering, hot or cold, provided material properties do not drop below those used in design. Where bending strain causes permanent deformation, the designer must confirm the effect has been allowed for under AS 4100 or AS 5100.6. Any cracking, tearing or coating damage from forming makes the piece nonconforming.

  • Hot forming and flame straightening (Clauses 6.6.2–6.6.3): heated areas must not exceed 620 °C, with 580–620 °C the preferred range for AS/NZS 3678 plate and AS/NZS 3679.1/3679.2 sections; quenched and tempered steel has a lower cap. Working in the blue heat range (250–380 °C) is prohibited, and peak temperature and cooling must be controlled.
  • Cold forming (Clause 6.6.4): minimum bend radii follow AS/NZS 3678 for plate and AS/NZS 3679.1 for sections; weld distortion is corrected mechanically, by limited local heat, or both.
  • NZ fracture critical bridge members (Clause 6.6.5): no mechanical cold working and a 600 °C cap.

Holing: punching limits, hole sizes and slots

Clause 6.7.1 allows holes to be machine cut, drilled or punched full size, or subpunched 3 mm undersize and reamed. Hand flame cutting of bolt holes is not allowed, other than as a site fix for base plate holes. The construction category directly changes the rule: at CC1 and CC2 full-size punching is permitted only in thinner, lower-strength material, whereas at CC3 and CC4 punching is limited to subpunching and reaming. Holes must be free of burrs, and full-size punching is excluded in seismic yielding regions.

Bolt hole geometry for members designed to AS 4100, AS 5100.6 or NZS 3404 – summary of Clauses 6.7.2–6.7.4
Hole typeKey limitWasher condition
Standard hole, bolt ≤ 24 mmBolt diameter + 2 mmNormal washers
Standard hole, bolt > 24 mmNot more than bolt diameter + 3 mmNormal washers
Base plate holeNot more than anchor diameter + 6 mmPlate washer ≥ 4 mm thick once clearance reaches 3 mm
Oversize holeGreater of 1.25 df or df + 8 mmHardened or plate washers under head and nut
Short slotStandard width; length per Clause 6.7.3Hardened or plate washers under head and nut
Long slotStandard width; length up to 2.5 dfAlternate plies only; plate washer ≥ 8 mm thick

Slots are only made where the specification shows them; otherwise approval is needed. Cold-formed members to AS/NZS 4600 follow tighter hole clearances. Clause 6.7 also covers countersinking (drilled after holing, bolt flush), pin holes, and weld access holes, whose length and height scale with plate thickness and which need smooth cut surfaces and a minimum 10 mm radius (Clause 6.7.7). Hole details feed straight into mechanical fastening.

Bearing surfaces, assembly and the pre-dispatch fit check

Full contact bearing surfaces must be identified in the specification and produced by cold sawing or machining (Clause 6.8). With members aligned within Appendix F, the gap between abutting ends must not exceed 1 mm, and must be within 0.5 mm over at least two-thirds of the contact area.

Clause 6.9 requires assembly to achieve the Appendix F fabrication and erection tolerances, temporary fabrication attachments to comply with Sections 6–8, and camber or pre-set to be shown in the specification. Clause 6.10 then requires the fit at more complex connection interfaces to be checked and documented before dispatch, using templates, accurate measurement, trial assembly or the method the specification nominates. For an offshore supplier this is the main defence against site misfits that cannot be fixed quickly; see geometrical tolerances.

Transit, supervision and New Zealand yielding regions

Clause 6.11 requires items to be protected before they leave the shop: free ends stiffened, distortion prevented, bearing surfaces protected, coating damage minimised, and loose fasteners and small parts packed and identified in containers. Clause 6.12 requires cutting, holing, shaping and assembly to be supervised by a competent person at CC2, CC3 and CC4; the informative note suggests a trade qualification plus about ten years' experience. Clause 6.13 adds New Zealand rules for seismic yielding regions: subpunch-and-ream for punched holes, a 12 µm roughness limit, and controlled thickness transitions.

Section 6 requirements that change with construction category (summary)
TopicCC1CC2CC3 / CC4
Full-size punched holesLimited by fy and thicknessLimited by fy and thicknessNot permitted – subpunch 3 mm and ream
Competent person supervisingNot required by 6.12RequiredRequired
NZ welder and WPS traceability via tracking system––Required (Clause 6.2)
Work method statements, Appendix F tolerancesRequiredRequiredRequired

This is a summary for orientation only. Refer to the current edition of AS/NZS 5131 for the full requirements, and to the project's construction specification, which governs.

Checklist do avaliador

O que um engenheiro, construtor ou auditor deve verificar em um fabricante CC3 para esta parte da AS/NZS 5131 – e as evidências a solicitar.

Cláusula · CCO que verificarEvidências
6.1.3 CC1–CC4Written work method statements exist for each Section 6 operation and are available at the workstation.Approved work method statements for cutting, holing, forming, assembly
6.1.1 CC1–CC4Cutting, drilling and forming equipment is maintained so wear does not affect output.Equipment maintenance and calibration records
6.2 CC1–CC4Mill certificates are held for each item and pieces stay identified through cutting; stamping limits respected.Mill certificate register, piece-mark tracking, marking procedure
6.4 CC1–CC4Customer supplied components and data are verified, safeguarded and losses recorded.Register of customer supplied items and data, damage reports
6.5.2 CC1–CC4Thermally cut edges meet Table 6.5 roughness; re-entrant corners have a radius of at least 10 mm.Cut-edge roughness checks, re-entrant corner details
6.6.2 CC1–CC4Hot work and flame straightening stay below 620 °C and avoid the blue heat range.Heat-straightening procedure, temperature crayons or pyrometer records
6.7.1 CC3–CC4No full-size punched holes; holes deburred and hand flame-cut bolt holes absent.CNC drilling programs, punching procedure showing subpunch and ream
6.7.2–6.7.4 CC1–CC4Hole, oversize and slot dimensions and washers match the clause limits and the specification.Shop drawings, hole schedules, washer call-outs
6.8 CC1–CC4Bearing ends are cold sawn or machined and meet the 1 mm / 0.5 mm gap criteria.Sawing or milling records, feeler-gauge gap checks
6.10 CC1–CC4Fit at complex interfaces is checked and documented before dispatch.Templates, dimensional reports or trial-assembly records
6.11 CC1–CC4Free ends stiffened, coatings and bearing surfaces protected, small parts boxed and labelled.Packing procedure, packing lists, photos
6.12 CC2–CC4A competent person supervises cutting, holing, shaping and assembly.Supervisor appointment, qualification and experience records

Em nossa fábrica

Como a World Steel aplica

01Digital model to CNCWorld Steel details members in Tekla, issues shop drawings and IFC, and drives CNC cutting and drilling from the same data, so hole patterns and cut geometry follow the approved model rather than manual layout.
02Traceability through cuttingWorld Steel's quality system maintains traceability from mill certificate to piece mark, with materials to AS/NZS 3678, 3679.1 and 1163 sourced from ACRS-certified mills where specified.
03Inspection points open to the clientProject ITPs set hold and witness points for fabrication stages, which the client's inspector can attend in person or by video, followed by a pre-shipment inspection.
04Packing for the erectorMembers are export packed by erection sequence, with erection drawings and bolt lists supporting the client's Australian erector on site.

Perguntas frequentes

Can a CC3 fabricator punch bolt holes full size?

No. Clause 6.7.1 limits punching at CC3 and CC4 to subpunching 3 mm undersize followed by reaming. Drilling or machine cutting full size is acceptable. Full-size punching is only available at CC1 and CC2 within strength and thickness limits.

What temperature limits apply to heat straightening?

Clause 6.6.3 refers back to Clause 6.6.2: heated areas must not exceed 620 °C for ordinary structural steels, with a lower limit for quenched and tempered grades. Bending or forming in the 250–380 °C blue heat range is not permitted, and cooling must be controlled.

Is a full trial assembly always required?

Not necessarily. Clause 6.10 requires the fit at more complex connection interfaces to be checked and documented before dispatch, but allows templates, accurate measurement, trial assembly or a method set by the specification. The construction specification may call for trial assembly on particular interfaces.

Who decides where hard stamping is not allowed?

The construction specification. Clause 6.2 allows hard stamping by default within limits (grades up to GR 350, away from fatigue-sensitive areas), but the designer should identify prohibited zones and say whether low-stress stamps may be used instead.

Precisa de um fabricante CC3 para um projeto australiano?

Envie os desenhos, a especificação de construção e a categoria de construção – respondemos com um plano de inspeção e ensaios, a lista de documentação e um preço discriminado.

Solicitar cotaçãoVer nosso certificado AS/NZS 5131 CC3