Fire-rated lining
Fire-rated gypsum board (Type X / F)
Glass-fibre-reinforced gypsum boards that keep their integrity in fire – the most economical fire-rated lining for walls, ceilings and steel encasement.
- ASTM C1396 Type X · EN 520 F
- Standard
- 30 – 120 min in systems
- Typical rating
- Dry – screwed to steel studs
- Installation
Fornecido pela World Steel com seu edifício metálico ou separadamente – um pedido, um embarque, um parceiro.
Visão geral
Sobre Fire-rated gypsum board (Type X / F)
Glass fibres keep the gypsum core together as its water of crystallisation turns to steam.
Ratings belong to tested wall, ceiling or encasement systems.
Combined with stone wool for higher ratings and acoustic performance.
Principais benefícios
- Economical fire-rated linings
- Fast, dry installation on steel framing
- Smooth finish ready for paint
- Also gives acoustic separation
World Steel · central de envoltória da edificação
Como usamos Fire-rated gypsum board (Type X / F) em edifícios metálicos
World Steel supplies fire boards with the steel structure, sized from the member schedule and packed with the steel, so the encasement contractor starts as soon as the frame is erected.
- 01Especificado junto com a estrutura – espessura, densidade e revestimento compatíveis com o projeto da cobertura, das paredes e de proteção contra incêndio.
- 02Quantitativos extraídos do mesmo modelo 3D que o aço, as terças e o fechamento.
- 03Embalado e enviado com o pacote de aço – um único cronograma de entrega na obra.
Aplicações
Onde Fire-rated gypsum board (Type X / F) é utilizado
- Fire-rated partitions, corridors and shafts
- Fire-rated ceilings under steel roofs and floors
- Encasement of steel columns in tested systems
Dados técnicos
Fire-rated gypsum board (Type X / F) – propriedades técnicas
Typical properties
| Propriedade | Unidade | Valor |
|---|---|---|
| Product standard | — | ASTM C1396 Type X · EN 520 type F · AS/NZS 2588 |
| Typical system ratings | min | 30 – 120 |
| Assessment | — | ASTM E119 / UL 263 · EN 1364 / EN 1365 · AS 1530.4 |
Valores conforme publicados pelo fabricante para este mercado. Sempre verifique a ficha técnica atual e as aprovações exigidas para seu projeto antes de fazer o pedido.
Fire-rated linings
Produtos relacionados
← Fire-rated lining boards and slabsFire Protection Boards →
FAQ
Perguntas frequentes
What thickness of fire-rated gypsum board (type x / f) do I need?
It depends on the member size (section factor), the critical temperature and the required fire rating – the fire engineer or the manufacturer's tested data gives a thickness for each member.
Does World Steel supply branded products?
Yes – we supply the brand and listed system your specification or authority requires. This page describes the product type.
Um único parceiro para estrutura e envoltória
Envie-nos seus desenhos ou planilha de quantitativos – cotamos o aço, o isolamento, as placas e os forros em conjunto e os enviamos como um único pacote.