Fire-rated lining
Fire-rated gypsum board (Type X / F)
Glass-fibre-reinforced gypsum boards that keep their integrity in fire – the most economical fire-rated lining for walls, ceilings and steel encasement.
- ASTM C1396 Type X · EN 520 F
- Standard
- 30 – 120 min in systems
- Typical rating
- Dry – screwed to steel studs
- Installation
Supplied by World Steel with your steel building or on its own – one order, one shipment, one partner.
Overview
About Fire-rated gypsum board (Type X / F)
Glass fibres keep the gypsum core together as its water of crystallisation turns to steam.
Ratings belong to tested wall, ceiling or encasement systems.
Combined with stone wool for higher ratings and acoustic performance.
Key benefits
- Economical fire-rated linings
- Fast, dry installation on steel framing
- Smooth finish ready for paint
- Also gives acoustic separation
World Steel · building envelope hub
How we use Fire-rated gypsum board (Type X / F) in steel buildings
World Steel supplies fire boards with the steel structure, sized from the member schedule and packed with the steel, so the encasement contractor starts as soon as the frame is erected.
- 01Specified with the structure – thickness, density and facing matched to the roof, wall and fire design.
- 02Quantities taken from the same 3D model as the steel, purlins and cladding.
- 03Packed and shipped with the steel package – one delivery schedule to site.
Applications
Where Fire-rated gypsum board (Type X / F) is used
- Fire-rated partitions, corridors and shafts
- Fire-rated ceilings under steel roofs and floors
- Encasement of steel columns in tested systems
Technical data
Fire-rated gypsum board (Type X / F) – technical properties
Typical properties
| Property | Unit | Value |
|---|---|---|
| Product standard | — | ASTM C1396 Type X · EN 520 type F · AS/NZS 2588 |
| Typical system ratings | min | 30 – 120 |
| Assessment | — | ASTM E119 / UL 263 · EN 1364 / EN 1365 · AS 1530.4 |
Values as published by the manufacturer for this market. Always check the current data sheet and the approvals required for your project before ordering.
Fire-rated linings
Related products
← Fire-rated lining boards and slabsFire Protection Boards →
FAQ
Frequently asked questions
What thickness of fire-rated gypsum board (type x / f) do I need?
It depends on the member size (section factor), the critical temperature and the required fire rating – the fire engineer or the manufacturer's tested data gives a thickness for each member.
Does World Steel supply branded products?
Yes – we supply the brand and listed system your specification or authority requires. This page describes the product type.
One partner for structure and envelope
Send us your drawings or bill of quantities – we quote the steel, insulation, boards and ceilings together and ship them as one package.