Fire-rated lining
Fire-rated gypsum board (Type X / F)
Glass-fibre-reinforced gypsum boards that keep their integrity in fire – the most economical fire-rated lining for walls, ceilings and steel encasement.
- ASTM C1396 Type X · EN 520 F
- Standard
- 30 – 120 min in systems
- Typical rating
- Dry – screwed to steel studs
- Installation
Fourni par World Steel avec votre bâtiment en acier ou séparément – une commande, une expédition, un partenaire.
Aperçu
À propos : Fire-rated gypsum board (Type X / F)
Glass fibres keep the gypsum core together as its water of crystallisation turns to steam.
Ratings belong to tested wall, ceiling or encasement systems.
Combined with stone wool for higher ratings and acoustic performance.
Principaux avantages
- Economical fire-rated linings
- Fast, dry installation on steel framing
- Smooth finish ready for paint
- Also gives acoustic separation
World Steel · plateforme enveloppe du bâtiment
Comment nous utilisons Fire-rated gypsum board (Type X / F) dans les bâtiments en acier
World Steel supplies fire boards with the steel structure, sized from the member schedule and packed with the steel, so the encasement contractor starts as soon as the frame is erected.
- 01Prescrit avec la structure – épaisseur, densité et parement adaptés à la conception de la toiture, des façades et de la sécurité incendie.
- 02Quantités issues de la même maquette 3D que l'acier, les pannes et le bardage.
- 03Emballé et expédié avec le lot acier – un seul planning de livraison sur chantier.
Applications
Où Fire-rated gypsum board (Type X / F) est utilisé
- Fire-rated partitions, corridors and shafts
- Fire-rated ceilings under steel roofs and floors
- Encasement of steel columns in tested systems
Données techniques
Fire-rated gypsum board (Type X / F) – caractéristiques techniques
Typical properties
| Caractéristique | Unité | Valeur |
|---|---|---|
| Product standard | — | ASTM C1396 Type X · EN 520 type F · AS/NZS 2588 |
| Typical system ratings | min | 30 – 120 |
| Assessment | — | ASTM E119 / UL 263 · EN 1364 / EN 1365 · AS 1530.4 |
Valeurs publiées par le fabricant pour ce marché. Vérifiez toujours la fiche technique en vigueur et les agréments requis pour votre projet avant de commander.
Fire-rated linings
Produits associés
← Fire-rated lining boards and slabsFire Protection Boards →
FAQ
Questions fréquentes
What thickness of fire-rated gypsum board (type x / f) do I need?
It depends on the member size (section factor), the critical temperature and the required fire rating – the fire engineer or the manufacturer's tested data gives a thickness for each member.
Does World Steel supply branded products?
Yes – we supply the brand and listed system your specification or authority requires. This page describes the product type.
Un seul partenaire pour la structure et l'enveloppe
Envoyez-nous vos plans ou votre bordereau des quantités – nous chiffrons ensemble l'acier, l'isolation, les plaques et les plafonds et les expédions en un seul lot.