Fire-rated glazing · partitions
Fire-rated glazed partitions
Fixed fire-resistant glazing in steel framing that separates fire compartments without closing them visually.
- Steel profiles
- Frame
- Fire-resistant, E / EW / EI
- Glass
- Per tested system
- Rating
Fornecido pela World Steel com seu edifício metálico ou separadamente – um pedido, um embarque, um parceiro.
Visão geral
Sobre Fire-rated glazed partitions
Glazed partitions are tested as non-loadbearing walls (EN 1364-1) and classified under EN 13501-2; the maximum pane size, frame and fixing details come from the tested system.
Where insulation (EI) is required the glass is a multi-layer intumescent interlayer type; integrity-only (E) glass is used where codes allow.
Integration with fire-rated glass doors keeps one appearance along the whole separation.
Principais benefícios
- Daylight through fire separations
- Tested pane sizes and frames
- Matches fire-rated glass doors
- Steel frames sized for wind and impact
World Steel · central de envoltória da edificação
Como usamos Fire-rated glazed partitions em edifícios metálicos
World Steel details the steel framing and head and base connections of glazed partitions with the structure.
Product-specific test reports, classification reports and certificates are supplied for the product selected for each project – this page describes the product type, not a certified product.
- 01Especificado junto com a estrutura – espessura, densidade e revestimento compatíveis com o projeto da cobertura, das paredes e de proteção contra incêndio.
- 02Quantitativos extraídos do mesmo modelo 3D que o aço, as terças e o fechamento.
- 03Embalado e enviado com o pacote de aço – um único cronograma de entrega na obra.
Aplicações
Onde Fire-rated glazed partitions é utilizado
- Offices and meeting rooms in industrial buildings
- Control rooms with views into the plant
- Atrium and corridor separations
Dados técnicos
Fire-rated glazed partitions – propriedades técnicas
Typical properties and standards
| Propriedade | Unidade | Valor |
|---|---|---|
| Fire test | — | EN 1364-1 · ASTM E119 / UL 263 (fire-resistive glazing) · UL 9 (windows) · AS 1530.4 |
| Classification | — | EN 13501-2 – E, EW, EI |
| Pane size | — | Limited to the tested size of the system |
| Safety glazing | — | EN 12600 · ANSI Z97.1 · AS 1288 |
Valores conforme publicados pelo fabricante para este mercado. Sempre verifique a ficha técnica atual e as aprovações exigidas para seu projeto antes de fazer o pedido.
Fire doors & glazing
Produtos relacionados
Fire-rated doors · steelFire-rated steel doorsetsVer produto →
Fire-rated doors · glazedFire-rated glass doorsVer produto →
Fire-rated doors · access panelsFire-rated access panelsVer produto →← Fire-rated doors and glazingFire-Rated Building Systems – Panels, Doors, Glazing, Shutters and Curtains →
FAQ
Perguntas frequentes
Can any glass be used in a fire-rated partition?
No – only fire-resistant glass tested in that frame system, within the tested pane sizes.
Is this product certified?
Certification belongs to a specific manufacturer’s product or tested system. We supply the test report, classification or listing accepted in your market for the product selected – it is confirmed per project, never assumed.
Um único parceiro para estrutura e envoltória
Envie-nos seus desenhos ou planilha de quantitativos – cotamos o aço, o isolamento, as placas e os forros em conjunto e os enviamos como um único pacote.