About Fire-rated glazed partitions
Glazed partitions are tested as non-loadbearing walls (EN 1364-1) and classified under EN 13501-2; the maximum pane size, frame and fixing details come from the tested system.
Where insulation (EI) is required the glass is a multi-layer intumescent interlayer type; integrity-only (E) glass is used where codes allow.
Integration with fire-rated glass doors keeps one appearance along the whole separation.
Key benefits
- Daylight through fire separations
- Tested pane sizes and frames
- Matches fire-rated glass doors
- Steel frames sized for wind and impact
World Steel · building envelope hub
How we use Fire-rated glazed partitions in steel buildings
World Steel details the steel framing and head and base connections of glazed partitions with the structure.
Product-specific test reports, classification reports and certificates are supplied for the product selected for each project – this page describes the product type, not a certified product.
- 01Specified with the structure – thickness, density and facing matched to the roof, wall and fire design.
- 02Quantities taken from the same 3D model as the steel, purlins and cladding.
- 03Packed and shipped with the steel package – one delivery schedule to site.
Applications
Where Fire-rated glazed partitions is used
- Offices and meeting rooms in industrial buildings
- Control rooms with views into the plant
- Atrium and corridor separations
Technical data
Fire-rated glazed partitions – technical properties
Typical properties and standards
| Property | Unit | Value |
|---|---|---|
| Fire test | — | EN 1364-1 · ASTM E119 / UL 263 (fire-resistive glazing) · UL 9 (windows) · AS 1530.4 |
| Classification | — | EN 13501-2 – E, EW, EI |
| Pane size | — | Limited to the tested size of the system |
| Safety glazing | — | EN 12600 · ANSI Z97.1 · AS 1288 |
Values as published by the manufacturer for this market. Always check the current data sheet and the approvals required for your project before ordering.
Fire doors & glazing
Related products
Fire-rated doors · steelFire-rated steel doorsetsView product →
Fire-rated doors · glazedFire-rated glass doorsView product →
Fire-rated doors · access panelsFire-rated access panelsView product →← Fire-rated doors and glazingFire-Rated Building Systems – Panels, Doors, Glazing, Shutters and Curtains →
FAQ
Frequently asked questions
Can any glass be used in a fire-rated partition?
No – only fire-resistant glass tested in that frame system, within the tested pane sizes.