Fire-rated glazing · partitions
Fire-rated glazed partitions
Fixed fire-resistant glazing in steel framing that separates fire compartments without closing them visually.
- Steel profiles
- Frame
- Fire-resistant, E / EW / EI
- Glass
- Per tested system
- Rating
Fornito da World Steel con il vostro edificio in acciaio o separatamente – un ordine, una spedizione, un partner.
Panoramica
Informazioni su Fire-rated glazed partitions
Glazed partitions are tested as non-loadbearing walls (EN 1364-1) and classified under EN 13501-2; the maximum pane size, frame and fixing details come from the tested system.
Where insulation (EI) is required the glass is a multi-layer intumescent interlayer type; integrity-only (E) glass is used where codes allow.
Integration with fire-rated glass doors keeps one appearance along the whole separation.
Vantaggi principali
- Daylight through fire separations
- Tested pane sizes and frames
- Matches fire-rated glass doors
- Steel frames sized for wind and impact
World Steel · hub per l'involucro edilizio
Come utilizziamo Fire-rated glazed partitions negli edifici in acciaio
World Steel details the steel framing and head and base connections of glazed partitions with the structure.
Product-specific test reports, classification reports and certificates are supplied for the product selected for each project – this page describes the product type, not a certified product.
- 01Specificato insieme alla struttura – spessore, densità e rivestimento adeguati al progetto di copertura, pareti e antincendio.
- 02Quantità ricavate dallo stesso modello 3D di acciaio, arcarecci e rivestimenti.
- 03Imballato e spedito con il pacchetto acciaio – un unico programma di consegna in cantiere.
Applicazioni
Dove si usa Fire-rated glazed partitions
- Offices and meeting rooms in industrial buildings
- Control rooms with views into the plant
- Atrium and corridor separations
Dati tecnici
Fire-rated glazed partitions – proprietà tecniche
Typical properties and standards
| Proprietà | Unità | Valore |
|---|---|---|
| Fire test | — | EN 1364-1 · ASTM E119 / UL 263 (fire-resistive glazing) · UL 9 (windows) · AS 1530.4 |
| Classification | — | EN 13501-2 – E, EW, EI |
| Pane size | — | Limited to the tested size of the system |
| Safety glazing | — | EN 12600 · ANSI Z97.1 · AS 1288 |
Valori pubblicati dal produttore per questo mercato. Prima dell'ordine verificate sempre la scheda tecnica aggiornata e le approvazioni richieste per il vostro progetto.
Fire doors & glazing
Prodotti correlati
Fire-rated doors · steelFire-rated steel doorsetsVedi prodotto →
Fire-rated doors · glazedFire-rated glass doorsVedi prodotto →
Fire-rated doors · access panelsFire-rated access panelsVedi prodotto →← Fire-rated doors and glazingFire-Rated Building Systems – Panels, Doors, Glazing, Shutters and Curtains →
FAQ
Domande frequenti
Can any glass be used in a fire-rated partition?
No – only fire-resistant glass tested in that frame system, within the tested pane sizes.
Is this product certified?
Certification belongs to a specific manufacturer’s product or tested system. We supply the test report, classification or listing accepted in your market for the product selected – it is confirmed per project, never assumed.
Un unico partner per struttura e involucro
Inviateci i disegni o il computo metrico – quotiamo insieme acciaio, isolamento, lastre e controsoffitti e li spediamo in un unico pacchetto.