Building trust, Assuring Success Client portal dang.victor@worldsteelgroup.com +84 902 881 833
World SteelBuilding trust, Assuring success
Fire-rated access panels – illustration

Product images: the manufacturer (official).

Fire-rated doors · access panels

Fire-rated access panels

Small doors for big risks: every access opening in a fire-rated wall, ceiling or shaft needs its own tested closure.

Steel frame and door
Body
Walls, ceilings, shafts
Use
Per tested panel
Rating

Request a quotation

Supplied by World Steel with your steel building or on its own – one order, one shipment, one partner.

Overview

About Fire-rated access panels

Access panels give maintenance access to valves, dampers, cables and plumbing behind fire-rated linings and inside shafts.

They are tested in the wall or ceiling type they will be installed in (for example EN 1634-1 or EN 1364-2, UL 10B / ASTM E119 assemblies, AS 1530.4) and must be latched and closed in normal use.

Sizes, lining type and orientation (wall or ceiling) are part of the tested scope.

Key benefits

  • Maintains the fire separation
  • Tested for wall or ceiling use
  • Lockable and self-latching versions
  • Matches board, panel and masonry walls

World Steel · building envelope hub

How we use Fire-rated access panels in steel buildings

World Steel supplies access panels with the fire-rated linings, panels and boards of the same package.

Product-specific test reports, classification reports and certificates are supplied for the product selected for each project – this page describes the product type, not a certified product.

  • 01Specified with the structure – thickness, density and facing matched to the roof, wall and fire design.
  • 02Quantities taken from the same 3D model as the steel, purlins and cladding.
  • 03Packed and shipped with the steel package – one delivery schedule to site.

Applications

Where Fire-rated access panels is used

  • Service shafts and risers
  • Fire-rated ceilings
  • Plant and electrical rooms

Technical data

Fire-rated access panels – technical properties

Typical properties and standards

PropertyUnitValue
Fire test—EN 1634-1 / EN 1364-2 · UL 10B / ASTM E119 · AS 1530.4
Classification—EN 13501-2 – EI
Mounting—Wall or ceiling, per tested lining type

Values as published by the manufacturer for this market. Always check the current data sheet and the approvals required for your project before ordering.

FAQ

Frequently asked questions

Can a standard access panel be used in a fire-rated wall?

No – it must be a fire-rated panel tested in that wall or ceiling type.

Is this product certified?

Certification belongs to a specific manufacturer’s product or tested system. We supply the test report, classification or listing accepted in your market for the product selected – it is confirmed per project, never assumed.

One partner for structure and envelope

Send us your drawings or bill of quantities – we quote the steel, insulation, boards and ceilings together and ship them as one package.

Request a quotation +84 902 881 833