Fire-rated doors · access panels
Fire-rated access panels
Small doors for big risks: every access opening in a fire-rated wall, ceiling or shaft needs its own tested closure.
- Steel frame and door
- Body
- Walls, ceilings, shafts
- Use
- Per tested panel
- Rating
World Steel が鉄骨建築と一括で、または単体で供給 – 一つの注文、一つの出荷、一つのパートナー。
概要
Fire-rated access panelsについて
Access panels give maintenance access to valves, dampers, cables and plumbing behind fire-rated linings and inside shafts.
They are tested in the wall or ceiling type they will be installed in (for example EN 1634-1 or EN 1364-2, UL 10B / ASTM E119 assemblies, AS 1530.4) and must be latched and closed in normal use.
Sizes, lining type and orientation (wall or ceiling) are part of the tested scope.
主なメリット
- Maintains the fire separation
- Tested for wall or ceiling use
- Lockable and self-latching versions
- Matches board, panel and masonry walls
World Steel · 外装材ハブ
鉄骨建築におけるFire-rated access panelsの活用
World Steel supplies access panels with the fire-rated linings, panels and boards of the same package.
Product-specific test reports, classification reports and certificates are supplied for the product selected for each project – this page describes the product type, not a certified product.
- 01構造と一体で仕様決定 – 厚さ、密度、表面材を屋根・外壁・耐火設計に合わせます。
- 02数量は鉄骨、母屋、外装材と同じ 3D モデルから算出。
- 03鉄骨パッケージとともに梱包・出荷 – 現場への納入スケジュールは一つです。
用途
Fire-rated access panelsの用途
- Service shafts and risers
- Fire-rated ceilings
- Plant and electrical rooms
技術データ
Fire-rated access panels – 技術特性
Typical properties and standards
| 特性 | 単位 | 値 |
|---|---|---|
| Fire test | — | EN 1634-1 / EN 1364-2 · UL 10B / ASTM E119 · AS 1530.4 |
| Classification | — | EN 13501-2 – EI |
| Mounting | — | Wall or ceiling, per tested lining type |
この市場向けにメーカーが公表している値です。ご注文前に必ず最新のデータシートと、プロジェクトに必要な認定をご確認ください。
Fire doors & glazing
関連製品
Fire-rated doors · steelFire-rated steel doorsets製品を見る →
Fire-rated doors · glazedFire-rated glass doors製品を見る →
Fire-rated glazing · partitionsFire-rated glazed partitions製品を見る →← Fire-rated doors and glazingFire-Rated Building Systems – Panels, Doors, Glazing, Shutters and Curtains →
FAQ
よくある質問
Can a standard access panel be used in a fire-rated wall?
No – it must be a fire-rated panel tested in that wall or ceiling type.
Is this product certified?
Certification belongs to a specific manufacturer’s product or tested system. We supply the test report, classification or listing accepted in your market for the product selected – it is confirmed per project, never assumed.