World SteelBuilding trust, Assuring success

Integrated structural steel & fire protection solutions

Advanced fire protection solutions for structural steel

Engineered Fire Resistance. Proven Performance. Optimized Cost.

Protecting steel structures with engineered fire protection coating systems designed to meet international fire resistance requirements while optimising coating thickness, material consumption, project costs and long-term durability.

  • R30 · R60 · R90 · R120 · R180Design requirements we engineer for – each system and member is checked against its approved data.
  • International fire test standardsEN 13381-8, ASTM E119 / UL 263, AS 1530.4, BS 476, UL 1709.
  • Engineered coating thicknessDFT per member from the section factor and the manufacturer's approved loading data.
  • Factory & on-site applicationShop application with the steel, or site application by the project's applicator.
  • Quality assuranceITP, environmental records, WFT and DFT inspection, batch traceability.
  • Project-specific solutionsInternational, Hempel, Jotun or PPG systems – chosen for the specification.

クイック・プロジェクト問い合わせ

下のプロジェクトフォームに進みます – 送信するまで何も送られません。

Fire engineering basics

Why structural steel requires fire protection

Steel is non-combustible – but like every material it loses strength and stiffness as it heats up.

In a building fire the gas temperature follows the standard fire curve (ISO 834, ASTM E119, AS 1530.4) and passes 800 °C in under 25 minutes. Unprotected steel members heat up quickly – thin, light sections fastest – and their yield strength and elastic modulus fall progressively above about 400 °C.

A member fails when it reaches its critical steel temperature: the temperature at which its reduced strength equals the load it carries in the fire. Critical temperatures are typically in the range of about 500–620 °C, depending on the load ratio and the member type, and are set by the structural fire design (EN 1993-1-2, AS 4100 Section 12, AISC 360 Appendix 4).

Passive fire protection insulates the steel so that it stays below its critical temperature for the period the building code requires – giving time to escape, for fire fighting and for structural stability.

Standard fire curve at 30 min
≈ 840 °C
Typical critical steel temperature
≈ 500 – 620 °C
Steel yield strength near 600 °C
≈ 47 % (EN 1993-1-2)

ガス温度:ISO 834 標準火災曲線。鋼材:無被覆部材、EN 1993-1-2 §4.2.5.1 の簡易伝熱計算(αc = 25 W/m²K、εm = 0.7、ksh = 1)。塗膜の図は説明用です – 発泡と性能は製品ごとに異なります。

Fire resistance performance

Engineered for different fire resistance requirements

Select a rating to see where it is typically required, how it is tested and which systems are usually considered. The required thickness always depends on the member, its critical temperature and the product's approved data.

R60標準耐火試験で 60 分間の荷重支持能力
代表的な用途
Offices, schools, retail and many multi-storey buildings; the most common building requirement.
試験・分類
EN 13381-8 / EN 13501-2 (R 60) · UL 263 (1 h) · AS 1530.4 (FRL 60/–/–) · BS 476-20/21
一般的に検討されるシステム
Thin-film intumescent – water-based or solvent-based, shop or site applied.
技術資料
Fire rating schedule · ETA / UL design / assessment report · loading table · ITP · DFT records
エンジニアリング上の考慮事項
Light sections with high section factors can need several times the thickness of heavy sections for the same rating.

必要な塗膜厚は次の要素で決まります:

  • Steel section factor (Hp/A, A/V, ksm or W/D)
  • Critical steel temperature from the structural fire design
  • Fire exposure – cellulosic or hydrocarbon, 3 or 4 sides
  • The coating product and its tested section shapes
  • Approved test and assessment data accepted in the project's country

耐火性能ごとに一つの DFT を公表することはしません – 同じ耐火性能でも、重量のある柱では 0.3 mm、軽量の梁では数 mm が必要になることがあります。

Systems

Our fire protection coating solutions

Four routes to a fire rating – chosen for the building, the exposure, the appearance and the cost. Product-specific data comes only from the manufacturer's approved documentation.

Thin-film intumescent coating (illustration)A

Cellulosic · buildings

Thin-film intumescent coating

Water-based or solvent-based acrylic coatings applied like paint over a compatible primer. In a fire they expand into an insulating char.

代表的な用途: Exposed and architectural steel, offices, retail, schools, airports, warehouses

表面外観: Smooth, paint-like finish; steel profile stays visible; topcoat in any colour

適合性・認証: Primers and topcoats approved by the intumescent manufacturer for that system

  • Slim and light – no extra load
  • Shop or site application; covers connections and cellular beams
  • Low-VOC water-based grades for occupied buildings
  • Thickness and cost rise sharply at long ratings and high section factors
  • Water-based grades need dry interiors or a topcoat; humidity slows drying
  • Transport and handling damage needs touch-up
Epoxy intumescent coating (illustration)B

Cellulosic & hydrocarbon · industry

Epoxy intumescent coating

Two-component, high-solids epoxy systems – very hard and durable. Building (cellulosic) grades reach long ratings; dedicated grades are tested for hydrocarbon pool and jet fires.

代表的な用途: Oil & gas, petrochemical and LNG plants, offshore, exterior and high-traffic steel; long cellulosic ratings

表面外観: Thick, hard film; architectural finish possible with topcoat

適合性・認証: Certification must match the fire scenario – a cellulosic approval does not cover hydrocarbon fire

  • Durable in C5 / exterior conditions; impact resistant
  • Fast cure – suitable for shop and module yards
  • Hydrocarbon (UL 1709) and jet-fire (ISO 22899-1) tested products
  • Higher material cost per litre; plural-component equipment
  • Mesh reinforcement required for some products and details
Cementitious fireproofing (illustration)C

Sprayed · concealed & industrial

Cementitious fireproofing

Sprayed fire-resistive materials (SFRM) – cement or gypsum binders with mineral aggregates or fibres – applied directly to steel.

代表的な用途: Concealed beams and decks, long ratings, car parks, industrial and petrochemical structures (dense grades)

表面外観: Textured; usually hidden behind ceilings or linings

適合性・認証: Primer only where the spray manufacturer approves it – some products need bare steel

  • Lowest cost per m² at long ratings
  • Fast over large areas and complex shapes
  • Wet trade on site – curing time, overspray protection
  • Low-density grades are easily damaged; inspection of thickness and density (ASTM E605)
Customised fire protection systems (illustration)D

Engineered for your project

Customised fire protection systems

Mixed solutions where one system is not the best answer everywhere – for example intumescent on exposed steel, boards on columns in public areas and sprays above ceilings.

設計の入力情報:

  • Project location and the authority's accepted approvals
  • Fire resistance per element
  • Steel section factors from the member schedule
  • Environment and durability (ISO 12944 category)
  • Applicable standards and certification route
  • Budget and programme
  • Application method – factory, site or both

耐火被覆システムを比較

耐火塗料は、World Steel が鉄骨建築向けに供給する8つの耐火製品グループの一つです – ボード、吹付け材、断熱材、耐火パネル、防火扉・ガラス、防火区画貫通処理材、防火・防煙カーテン。 総合的な耐火ソリューション →

Engineering-based coating thickness design

Precision engineering. Optimized coating consumption.

The required dry film thickness is not a number per rating – it is calculated member by member. Getting it right avoids both non-compliance and paying for coating that adds nothing.

Avoid excessive consumptionHeavy sections need far less coating than light ones for the same rating; one blanket thickness wastes material.
Reduce unnecessary costGrouping members by section factor and using the right critical temperature can lower the total volume.
Ensure complianceEvery thickness traces back to the product's approved loading table and certification.
Plan the projectVolumes, coats and drying time feed the fabrication and coating programme.
Support documentationThe DFT schedule becomes the inspection reference and part of the handover dossier.
符号種類寸法(mm)kg/m長さ m数量加熱面任意 Hp mm認定データによる DFT(mm)

例示行です – 部材リストに置き換えてください。面積は板要素の形状(フィレット半径は無視)から、または kg/m が入力された場合はそこから算出(ρ = 7850 kg/m³)。

符号A mm²Hp mmHp/A m⁻¹ksm m²/tW/D lb/ft/in塗装面積 m²必要 DFT
総塗装面積0

Preliminary calculations are provided for estimation purposes only. Final coating thickness and fire protection system selection must be verified against the approved product documentation, applicable project requirements and relevant engineering assessments.

Standards library

International fire protection standards

Fire test standards, classification standards, structural fire design codes and product approval routes are different things – a project usually needs one of each.

耐火試験規格国際

ISO 834-1

Fire-resistance tests – Elements of building construction

Defines the standard (cellulosic) time–temperature curve used by most national fire tests.

耐火試験規格国際

ISO 22899-1

Determination of the resistance to jet fires of passive fire protection materials

Jet-fire test for PFP used on oil, gas and process structures.

耐火試験規格欧州

EN 1363-1 / EN 1363-2

Fire resistance tests – General requirements; alternative and additional procedures

European fire test furnace conditions; EN 1363-2 includes the hydrocarbon curve.

耐火試験規格欧州

EN 13381-8

Test methods for determining the contribution to the fire resistance of structural members – Reactive protection applied to steel members

Tests and assessment of intumescent coatings; produces the data behind the loading tables.

耐火試験規格欧州

EN 13381-4

… – Applied passive protection products to steel members

Tests and assessment for boards, sprays and other passive products.

分類規格欧州

EN 13501-2

Fire classification of construction products and building elements – Classification using data from fire resistance tests

Expresses results as R 30, R 60, R 90, R 120, R 180 …

製品認定欧州

EAD 350402-00-1106

European Assessment Document – Reactive coatings for fire protection of steel elements

Route to a European Technical Assessment (ETA) and CE marking; includes durability types X, Y, Z1, Z2.

構造設計規格欧州

EN 1993-1-2

Eurocode 3 – Design of steel structures – Structural fire design

Steel properties at elevated temperature, critical temperature and section factor rules.

耐火試験規格英国

BS 476-20 / 21

Fire tests on building materials and structures – Methods for determination of the fire resistance of elements of construction

UK national fire tests, still referenced; EN 13381-8 data is widely accepted in the UK.

耐火試験規格米国

ASTM E119

Standard Test Methods for Fire Tests of Building Construction and Materials

US standard fire test; ratings in hours.

耐火試験規格米国

UL 263

Fire Tests of Building Construction and Materials

UL's equivalent test; UL listed designs give the thickness for each design and W/D.

耐火試験規格米国

UL 1709

Rapid Rise Fire Tests of Protection Materials for Structural Steel

Hydrocarbon pool-fire test for petrochemical structures.

構造設計規格米国

AISC 360 Appendix 4

Structural Design for Fire Conditions

Performance-based structural fire design in the US.

耐火試験規格豪州

AS 1530.4

Methods for fire tests on building materials, components and structures – Fire-resistance tests for elements of construction

Australian fire test; results as FRL (structural adequacy/integrity/insulation).

構造設計規格豪州

AS 4100 Section 12

Steel structures – Fire

Limiting steel temperature and exposed surface area to mass ratio (ksm).

耐火試験規格欧州

EN 16623

Paints and varnishes – Reactive coatings for fire protection of metallic substrates – Definitions, requirements, characteristics and marking

Durability and performance requirements for reactive coatings; one of the test routes accepted in Singapore.

耐火試験規格英国

BS 8202-2

Coatings for fire protection of building elements – Code of practice for the use of intumescent coating systems to metallic substrates for providing fire resistance

Durability and weathering guidance used with BS 476-21 or AS 1530.4 data, including in Singapore.

製品認定シンガポール

SCDF Fire Code · Table 11A

Singapore Fire Code – Regulated fire safety products and materials (Product Listing Scheme)

Intumescent coating systems for structural steel are regulated products: each needs a Certificate of Conformity from an accredited certification body before use in Singapore.

規格が記載されていても、すべての製品がその認証を受けているとは限りません – 選択した製品の認定書に試験規格と適用範囲が記載されています。

Certification routes

Fire certifications for every market

World Steel supplies intumescent systems from leading manufacturers with the approval your project's authority accepts – Singapore Certificate of Conformity, UL listings, BS 476 assessments, Australian AS 1530.4 / AS 4100 assessments and European ETA / CE marking. The certificate always belongs to the product; the matrix shows what each manufacturer publishes.

Singapore CoCSCDF 製品登録制度(PLS)に基づく適合証明書(認定認証機関発行)SCDF Fire Code · PLS
ULUL 263 / ASTM E119 による UL 登録設計、炭化水素火災は UL 1709UL Product iQ
BS 476BS 476-20/21 による評価、第三者認証(例:Certifire)UK · Middle East · Asia
AS 1530.4 / AS 4100豪州の試験・評価報告書、NCC に基づく FRLAustralia · New Zealand
EN 13381-8 / ETAEAD 350402 に基づく欧州技術評価(ETA)と CE マーキングEurope · UK
製品Singapore CoCULBS 476AS 1530.4 / AS 4100EN 13381-8 / ETA
InternationalInterchar 404 ?CoC confirmed per project ? ? ? ✓ETA-09/0259出典
InternationalInterchar 963 ?CoC confirmed per project ? ◐BS 476-21 (product page)出典 ? ✓ETA-14/0043出典
InternationalInterchar 1120 ?CoC confirmed per project ◐UL 263 (brochure)出典 ✓BS 476-20/21 · Certifire出典 ◐AS 1530.4 · AS 4100出典 ✓ETA-20/1193出典
InternationalInterchar 1160 ?CoC confirmed per project ? ? ◐AS 1530.4 · AS 4100 (product page)出典 ✓ETA-20/1192出典
InternationalChartek 7E ?CoC confirmed per project ? ? ? ?
InternationalChartek 1709 ?CoC confirmed per project ✓ANSI/UL 1709 listed出典 ? ? ✓ETA-10/0086出典
InternationalChartek ONE ?CoC confirmed per project ◐UL 1709 Ed. 5出典 ? ? ?
HempelHempacore One 43600 ?CoC confirmed per project ? ? ◐AS 4100 – 3rd-party certified (PDS)出典 ✓ETA 12/0581出典
HempelHempacore One FD 43601 ?CoC confirmed per project ? ✓Certifire (PDS)出典 ◐AS 4100 – 3rd-party certified (PDS)出典 ✓ETA 12/0581出典
HempelHempacore AQ 48860 ?CoC confirmed per project ? ✓BS 476-21 assessment up to 90 min出典 ? ✓ETA 13/1054出典
JotunSteelMaster 600WF / 900WF / 1200WF ?CoC confirmed per project ? ✓Certifire CF 5631 (600WF) · CF 6140 (900WF) · CF 5243 (1200WF)出典 ◐AS 4100 (1200WF)出典 ✓ETA-22/0047 · ETA-24/0831 · ETA-22/0351出典
JotunSteelMaster 60SB / 90SB (QD) ?CoC confirmed per project ? ✓Certifire CF 5170 (60SB) · BS 476-20/21 (90SB)出典 ? ✓ETA-22/0350 · ETA 24/0096出典
JotunSteelMaster 1200HPE ?CoC confirmed per project ◐UL 263 exterior · UL 2431 I-A出典 ✓Certifire CF 5857 (up to 180 min)出典 ◐AS 4100 (TDS) ✓ETA-21/1019出典
JotunJotachar 1709 ?CoC confirmed per project ◐UL 1709 · UL 2431出典 ? ? ?
PPGPPG STEELGUARD 651 ?CoC confirmed per project ? ✓BS 476-20/21 assessed出典 ? ✓ETA 22/0050出典
PPGPPG STEELGUARD 701 / 801 ?CoC confirmed per project ? ✓BS 476-20/21 assessed出典 ? ✓ETA 22/0048出典
PPGPPG STEELGUARD 951 ?CoC confirmed per project ◐UL 263 · UL 2431 I-A (PDS)出典 ◐BS 476 (PDS)出典 ? ✓ETA 22/0790出典
PPGPPG PITT-CHAR NX ?CoC confirmed per project ✓UL 1709 Rev. 5 · UL 2431 (UL Verify V503293)出典 ◐BS 476 tested (PDS)出典 ? ✓ETA 21/1088出典

✓ = 認証機関が登録または認定書を公表 · ◐ = メーカーが表示(データシート / ウェブサイト)– 認定書はご請求により提供 · ? = 公開情報では未確認 – メーカーが保有している場合がありますのでお問い合わせください · — = 該当なし。認定書は特定の製品、耐火性能、断面形状、寸法を対象とします。World Steel は提案ごとに、採用ルートの最新認定書と膜厚表を提供します。

Engineering lookup tables

Lookup tables by standard

Reference values calculated from the published formulas and tables of each standard – fire curves, steel strength at temperature, critical and limiting temperatures, section-factor conversions and rating equivalents. Coating thickness itself always comes from the selected product's approved loading table.

時間(分)ISO 834 · EN 1363-1 · BS 476-20 · AS 1530.4 (°C)ASTM E119 · UL 263 (°C)EN 1363-2 炭化水素 (°C)
5576538948
106787041034
15739—1071
308428431098
45902—1100
609459271100
901006—1100
120104910101100
180111010521100
240115310931100

ISO 834:T = 20 + 345·log10(8t + 1)。ASTM E119:公表曲線の値(5 分で 1000 °F … 4 時間で 2000 °F)。EN 1363-2:T = 20 + 1080(1 − 0.325e^−0.167t − 0.675e^−2.5t)。UL 1709(急速昇温)は 5 分以内に 2000 °F(1093 °C)に達します。

Value engineering

Reduce coating costs without compromising fire performance

Ten factors decide the installed cost of an intumescent system. Most of them can be engineered.

  1. Steel section factorThe biggest driver – light, thin members need much more coating. Heavier sections can reduce the total cost.
  2. Fire resistance durationR120 can need several times the DFT of R60 on the same member.
  3. Critical steel temperatureA lower load ratio gives a higher critical temperature and a thinner coating – ask the engineer to calculate it.
  4. Steel surface areaCoating is bought per litre and applied per m² – the member schedule sets both.
  5. Required DFTFrom the approved loading table, member by member.
  6. Product volume solidsLitres needed = area × DFT ÷ volume solids – high-solids products need fewer litres for the same film.
  7. Application lossesOverspray, equipment and shape losses – lower in the shop than on site.
  8. Surface preparationBlast grade and primer system required by the intumescent manufacturer.
  9. Environmental conditionsHumidity and temperature affect drying, the number of coats and the programme.
  10. Inspection requirementsDFT readings per member, hold points and third-party inspection.

コスト試算ツールを開く コスト最適化を依頼

Factory or site

Flexible fire protection application solutions

World Steel fabricates, blasts and paints structural steel in its own shop. Intumescent can be applied there with the steel – or on site by the project's applicator.

World Steel 工場の塗装工場
評価項目工場塗装現場塗装
Environmental controlControlled temperature and humidity; steel temperature checkedExposed to weather; enclosures or heating may be needed
Application qualityMembers turned and coated in the best positionOverhead and difficult access; scaffolds or lifts
InspectionEvery member measured before dispatchInspection follows erection sequence
Project scheduleRuns in parallel with site worksAdds a trade after erection
TransportationCareful packing and supports neededNo transport risk to the coating
Coating damageHandling and erection damage at supports and connectionsMinimal
Touch-upConnections and damaged areas after erectionNot applicable
Overall costUsually lower – efficient application, fewer site hoursHigher site labour and access costs

Many export projects combine both: the full system is applied in the factory and connections, bolts and damaged areas are completed on site with the same product, by a procedure agreed in the ITP.

  1. 製作
  2. ブラスト処理
  3. プライマー
  4. 発泡性塗料の塗装
  5. 上塗り
  6. DFT 検査
  7. 梱包・出荷
  8. 建方・タッチアップ

Quality assurance

Quality you can verify

Coating quality is controlled step by step and recorded – so the fire engineer and the authority can see that every member has the thickness it needs.

  1. 01Surface preparation inspection

    Blast cleanliness and profile checked against the primer data sheet before coating.

  2. 02Primer compatibility verification

    Primer type and thickness confirmed against the intumescent manufacturer's approved list.

  3. 03Environmental monitoring

    Air and steel temperature, relative humidity and dew point recorded before and during application.

  4. 04Coating application

    Airless spray by trained applicators following the product application guide.

  5. 05Wet film thickness monitoring

    WFT checks during application to steer each coat to the target.

  6. 06Dry film thickness inspection

    Calibrated gauges, readings per member against the DFT schedule.

  7. 07Final inspection

    Visual check, topcoat, marking and release of each lot.

  8. 08Handover documentation

    Coating report, product certificates, batch numbers and DFT records in the project dossier.

品質書類(イラスト)

提出する品質記録

  • Inspection & test plan (ITP)
  • Surface preparation records
  • Environmental records
  • Batch traceability
  • WFT reports
  • DFT reports
  • Gauge calibration certificates
  • NCR / CAR
  • Final inspection reports

World Steel の品質管理 →

Industries

Fire protection solutions across industries

Each industry brings its own fire scenario, exposure and appearance requirements.

Industrial buildings

Industrial buildings

Factories and plants where escape routes, mezzanines and compartment walls need rated steel.

代表的な部材: Columns, rafters, crane girders, mezzanines

規格: Local building code · EN 13381-8 / UL 263 / AS 1530.4

鉄骨ソリューション →
Steel warehouses

Steel warehouses

Often unrated, but columns at fire walls, racking zones and offices may need protection.

代表的な部材: Portal frames, columns at firewalls, mezzanines

規格: Code and insurer requirements

鉄骨ソリューション →
Logistics centres

Logistics centres

Large compartments with offices and mezzanines – protection targeted where it is required.

代表的な部材: Columns, office blocks, dock structures

規格: Building code · insurer rules

鉄骨ソリューション →
Commercial buildings

Commercial buildings

Offices and retail – typically R60 to R120 with exposed, architectural steel.

代表的な部材: Beams, columns, cellular beams, bracing

規格: EN 13381-8 · UL 263 · AS 1530.4

鉄骨ソリューション →
Airports

Airports

Terminals with exposed long-span steel where appearance and performance-based design matter.

代表的な部材: Long-span roof trusses, columns, hollow sections

規格: Project specification · fire engineering

鉄骨ソリューション →
Data centres

Data centres

Compartmentation and continuity of service drive the fire strategy.

代表的な部材: Frames, plant platforms, cable and pipe supports

規格: Building code · owner standards

鉄骨ソリューション →
Energy facilities

Energy facilities

Hydrocarbon pool and jet-fire scenarios need epoxy systems tested for them.

代表的な部材: Pipe racks, vessel skirts, modules

規格: UL 1709 · ISO 22899-1 · owner specs

鉄骨ソリューション →
Infrastructure projects

Infrastructure projects

Exterior and semi-exposed steel where durability and inspection access are key.

代表的な部材: Bridges, stations, tunnels, walkways

規格: Project specification

鉄骨ソリューション →

Project experience

Proven solutions. Real project results.

Fire protection case studies are published here once each project and its data are verified. In the meantime, see the World Steel project portfolio.

検証済みの耐火被覆事例をここに掲載予定です。データが確認された完了プロジェクトのみを公開します。

World Steel のプロジェクトポートフォリオを見る

Knowledge centre

Fire protection engineering knowledge center

Practical guides for owners, engineers and contractors.

01

What is intumescent fire protection coating?

Intumescent coatings are thin, paint-like systems that swell into an insulating char in a fire and keep structural steel below its critical temperature. What they are, where they are used and what they are not.

2 分で読めます →
02

How does intumescent paint work?

From a thin film to an insulating char: the chemistry and physics of intumescent coatings in a fire, and why expansion and performance are specific to each product.

2 分で読めます →
03

R30, R60, R90 and R120 explained

What R30, R60, R90 and R120 mean, how they relate to FRL in Australia and hour ratings in the US, and why a higher rating does not simply mean a proportionally thicker coating.

2 分で読めます →
04

How to calculate steel section factor (Hp/A)

The section factor Hp/A decides how fast a steel member heats up and how much fire protection it needs. Formulas for I-sections, hollow sections and boxed protection, with worked examples and the US and Australian equivalents.

2 分で読めます →
05

How to determine intumescent coating thickness

Coating thickness is read from the product's approved loading table using the fire rating, critical temperature, section shape, exposure and section factor. The step-by-step method – and the limits you must not cross.

2 分で読めます →
06

Intumescent vs cementitious fireproofing

Thin, decorative intumescent coatings or economical cementitious sprays? A side-by-side comparison of appearance, ratings, durability, application and cost to choose the right fireproofing.

2 分で読めます →
07

Fire protection for steel warehouses

Do steel warehouses need fire protection? When codes and insurers require it, which members are usually protected and how to keep the cost under control in large logistics buildings.

2 分で読めます →
08

Factory vs site application of intumescent coatings

Applying intumescent coating in the fabrication shop or on site: quality, programme, transport, damage, touch-up and cost compared – and how to combine both.

2 分で読めます →
09

Fire protection coating cost – what drives it

Why there is no single price per square metre for intumescent coating, how to calculate litres from area, DFT and volume solids, and the levers that reduce installed cost without reducing fire performance.

2 分で読めます →
10

International fire protection standards for structural steel

EN 13381-8, EN 13501-2, BS 476, ASTM E119, UL 263, UL 1709 and AS 1530.4 – what each standard does, and the difference between fire tests, classification, structural design and product approval.

2 分で読めます →

FAQ

Frequently asked questions

Can you supply intumescent coatings for projects in Singapore, the US, the UK or Australia?

Yes. We select a product that holds the approval your authority accepts: a Singapore Certificate of Conformity (SCDF Product Listing Scheme), a UL listed design (UL 263 / UL 1709), a BS 476 assessment or Certifire certificate, an Australian AS 1530.4 / AS 4100 assessment, or a European ETA. The certificate and its loading table are submitted with the proposal; where a product's certificate for a market is not published, we confirm it with the manufacturer before quoting.

What is fire protection coating for structural steel?

A coating system – usually primer, intumescent basecoat and topcoat – that insulates steel in a fire so it stays below its critical temperature for the required time. Cementitious sprays and boards do the same job by other means.

How does intumescent coating work?

When heated, the coating softens and chemical reactions release gases that expand it into a thick carbon char. The char has low thermal conductivity and slows the heating of the steel. The degree of expansion is specific to each product.

What is the difference between R60 and R120?

The time in minutes for which the member must keep its load-bearing function in the standard fire test – 60 or 120 minutes. R120 usually needs a much thicker coating or a different system on the same member.

How thick should fire protection coating be?

There is no single thickness per rating. The DFT is read from the product's approved loading table for each member's section factor, critical temperature, rating and exposure – from a few tenths of a millimetre to several millimetres.

How much does intumescent coating cost per square meter?

It depends on the DFT (which depends on the member), the product, volume solids, surface preparation, location and inspection. Use the cost estimator with your own unit prices, or send us the member schedule for a priced proposal.

Can coating be applied at the factory?

Yes. World Steel can apply the system in its painting shop with the steel; connections and handling damage are completed on site with the same product.

Can coating be applied over galvanized steel?

Only with a pre-treatment and primer or tie-coat that the intumescent manufacturer approves for galvanized substrates, and within the scope of its fire test data. Check this before specifying.

Can fire protection coating be used outdoors?

Some systems are assessed for exterior exposure (for example durability type X under EAD 350402) with a specified topcoat; epoxy systems are designed for harsh exterior and offshore conditions. Water-based grades are usually for dry interiors.

What is the expected service life?

It depends on the product, its durability classification, the exposure and maintenance. Manufacturers state durability for their systems; inspect regularly and repair damage with the same system.

What international standards apply?

Typically EN 13381-8 with EN 13501-2 in Europe, UL 263 / ASTM E119 in the US, AS 1530.4 with AS 4100 in Australia, BS 476 in the UK, and UL 1709 for hydrocarbon fires. Your authority decides which approvals are accepted.

How is coating thickness inspected?

With calibrated magnetic or electronic DFT gauges on each member, at a frequency set in the ITP, and compared with the DFT schedule. Wet film checks guide the applicator during spraying.

What information is required for a quotation?

Structural drawings or a member schedule with section sizes and lengths, the fire rating per element, exposure (3 or 4 sides), critical temperatures if known, the environment, accepted standards or approvals, application location and the programme.

Download centre

Technical documents & engineering resources

Templates from World Steel and links to the manufacturers' official product information. Project-specific test and classification data is sent on request.

資料カテゴリー種類改訂 / 日付
Fire protection member schedule – templateMember list with section, length, quantity, exposure, rating and critical temperature – the input for a thickness design.Engineering templatesCSV · < 1 KBA 2026-10-16 ダウンロード
DFT inspection record – templatePer-member DFT readings against the schedule, with gauge and environmental data.Inspection checklistsCSV · < 1 KBA 2026-10-16 ダウンロード
Fire protection technical questionnaireThe questions we ask to engineer a fire protection solution.Technical questionnairesDOCX · 37 KBA 2026-10-16 ダウンロード
International – passive fire protection productsInterchar and Chartek ranges on the manufacturer's website.Product brochuresWeb— 開く
Hempel – Hempacore rangeHempacore intumescent coatings on the manufacturer's website.Product brochuresWeb— 開く
Jotun – SteelMaster productsSteelMaster intumescent coatings on the manufacturer's website.Product brochuresWeb— 開く
PPG – STEELGUARD 651Product page with data sheets on the manufacturer's website.Technical data sheetsWeb— 開く
Interchar 404 – ETA-09/0259 (DIBt)European Technical Assessment with the approved DFT tables, published by DIBt.Approved thickness tablesWeb— 開く
Interchar 963 – ETA-14/0043 (DIBt)European Technical Assessment with the approved DFT tables, published by DIBt.Approved thickness tablesWeb— 開く
Chartek 1709 – ETA-10/0086 (DIBt)European Technical Assessment with the approved DFT tables, published by DIBt.Approved thickness tablesWeb— 開く
Hempacore ONE – ETA 12/0581 (ITeC)European Technical Assessment with the approved DFT tables, published by ITeC.Approved thickness tablesWeb— 開く
Approved loading tables for the selected systemIssued for the selected product and the project's certification route.Approved thickness tablesご請求により提供— 請求
Fire test and classification reportsSupplied with the proposal for the accepted approval (ETA, UL design, AS 1530.4 assessment).Fire test reportsご請求により提供— 請求
Technical and safety data sheetsCurrent TDS and SDS of every component of the proposed system.Safety data sheetsご請求により提供— 請求
Coating ITP and application procedureProject-specific inspection and test plan and touch-up procedure.Application guidelinesご請求により提供— 請求

Technical proposal

Get an engineered fire protection solution for your project

Send the project data and drawings – our engineers review the fire strategy, select the system and return a technical and commercial proposal.

連絡先
プロジェクト
耐火要件
ファイル

PDF、Excel、Word、DWG、IFC または ZIP。大容量ファイルは要件欄にダウンロードリンクをご記入ください。

参照番号は次のページとメールでお知らせします。

Your steel structure deserves engineered fire protection

Protect Structural Integrity. Optimize Project Costs. Meet International Standards.

見積もりを依頼 エンジニアリングチームに相談 技術質問票をダウンロード

会社
World Steel Construction JSC
営業・技術窓口
Victor Dang – Global Sales Director & COO
事務所
Ho Chi Minh City, Vietnam
工場
Hai Son Industrial Park, Tay Ninh, Vietnam
ご相談

次のプロジェクト

海外で鋼構造物をご計画ですか?

図面または IFC モデルをお送りください。積算チームが製作範囲、工程、納入価格をご回答します。