SFRM · concealed steel
Low-density cementitious spray
A light cementitious spray for steel hidden above ceilings and inside walls – fast to apply over large areas, ratings up to about four hours.
- Low
- Density class
- up to ≈ 4 h
- Typical rating
- Interior, concealed
- Exposure
Fornecido pela World Steel com seu edifício metálico ou separadamente – um pedido, um embarque, um parceiro.
Visão geral
Sobre Low-density cementitious spray
Sprayed directly onto clean, primed or bare steel as specified, in one or more passes.
Thickness set by the member, rating and listed design – measured to ASTM E605.
Covered by ceilings or linings – not for exposed, wet or high-traffic areas.
Principais benefícios
- Lowest cost per m² for long ratings
- Fast application over large areas
- Covers complex shapes and connections
- Also protects metal decks
World Steel · central de envoltória da edificação
Como usamos Low-density cementitious spray em edifícios metálicos
World Steel coordinates sprayed fire protection with the steel: compatible primers, clean surfaces and member-by-member thickness schedules from the fire design.
- 01Especificado junto com a estrutura – espessura, densidade e revestimento compatíveis com o projeto da cobertura, das paredes e de proteção contra incêndio.
- 02Quantitativos extraídos do mesmo modelo 3D que o aço, as terças e o fechamento.
- 03Embalado e enviado com o pacote de aço – um único cronograma de entrega na obra.
Aplicações
Onde Low-density cementitious spray é utilizado
- Concealed beams and columns in offices and hotels
- Steel and metal decks above ceilings
- High-rise steel frames
Dados técnicos
Low-density cementitious spray – propriedades técnicas
Typical properties
| Propriedade | Unidade | Valor |
|---|---|---|
| Density | kg/m³ | low – typically ≈ 240 – 350 |
| Typical rating range | h | 1 – 4 |
| Test standards | — | ASTM E605 (thickness, density) · ASTM E736 (cohesion / adhesion) · UL 263 · EN 13381-4 |
Valores conforme publicados pelo fabricante para este mercado. Sempre verifique a ficha técnica atual e as aprovações exigidas para seu projeto antes de fazer o pedido.
Sprayed fire-resistive materials
Produtos relacionados
SFRM · gypsum-basedGypsum-based sprayed fireproofingVer produto →
SFRM · exposed and industrialMedium- and high-density cementitious sprayVer produto →
SFRM · medium densityMedium-density cementitious sprayVer produto →
SFRM · lightweightVermiculite / perlite sprayVer produto →← Cementitious and mineral spraysSprayed Fire-Resistive Materials (SFRM) →
FAQ
Perguntas frequentes
What thickness of low-density cementitious spray do I need?
It depends on the member size (section factor), the critical temperature and the required fire rating – the fire engineer or the manufacturer's tested data gives a thickness for each member.
Does World Steel supply branded products?
Yes – we supply the brand and listed system your specification or authority requires. This page describes the product type.
Um único parceiro para estrutura e envoltória
Envie-nos seus desenhos ou planilha de quantitativos – cotamos o aço, o isolamento, as placas e os forros em conjunto e os enviamos como um único pacote.