Building trust, Assuring Success Client portal dang.victor@worldsteelgroup.com +84 902 881 833
World SteelBuilding trust, Assuring success
Low-density cementitious spray – illustration

Product images: the manufacturer (official).

SFRM · concealed steel

Low-density cementitious spray

A light cementitious spray for steel hidden above ceilings and inside walls – fast to apply over large areas, ratings up to about four hours.

Low
Density class
up to ≈ 4 h
Typical rating
Interior, concealed
Exposure

Request a quotation

Supplied by World Steel with your steel building or on its own – one order, one shipment, one partner.

Overview

About Low-density cementitious spray

Sprayed directly onto clean, primed or bare steel as specified, in one or more passes.

Thickness set by the member, rating and listed design – measured to ASTM E605.

Covered by ceilings or linings – not for exposed, wet or high-traffic areas.

Key benefits

  • Lowest cost per m² for long ratings
  • Fast application over large areas
  • Covers complex shapes and connections
  • Also protects metal decks

World Steel · building envelope hub

How we use Low-density cementitious spray in steel buildings

World Steel coordinates sprayed fire protection with the steel: compatible primers, clean surfaces and member-by-member thickness schedules from the fire design.

  • 01Specified with the structure – thickness, density and facing matched to the roof, wall and fire design.
  • 02Quantities taken from the same 3D model as the steel, purlins and cladding.
  • 03Packed and shipped with the steel package – one delivery schedule to site.

Applications

Where Low-density cementitious spray is used

  • Concealed beams and columns in offices and hotels
  • Steel and metal decks above ceilings
  • High-rise steel frames

Technical data

Low-density cementitious spray – technical properties

Typical properties

PropertyUnitValue
Densitykg/m³low – typically ≈ 240 – 350
Typical rating rangeh1 – 4
Test standards—ASTM E605 (thickness, density) · ASTM E736 (cohesion / adhesion) · UL 263 · EN 13381-4

Values as published by the manufacturer for this market. Always check the current data sheet and the approvals required for your project before ordering.

FAQ

Frequently asked questions

What thickness of low-density cementitious spray do I need?

It depends on the member size (section factor), the critical temperature and the required fire rating – the fire engineer or the manufacturer's tested data gives a thickness for each member.

Does World Steel supply branded products?

Yes – we supply the brand and listed system your specification or authority requires. This page describes the product type.

One partner for structure and envelope

Send us your drawings or bill of quantities – we quote the steel, insulation, boards and ceilings together and ship them as one package.

Request a quotation +84 902 881 833