Gypsum-based sprayed fireproofing – illustration

Product images: the manufacturer (official).

SFRM · gypsum-based

Gypsum-based sprayed fireproofing

A lightweight gypsum spray for interior beams, columns and decks hidden behind ceilings and linings.

Gypsum
Binder
Interior, dry, concealed
Exposure
Per listed design
Rating

Request a quotation

Supplied by World Steel with your steel building or on its own – one order, one shipment, one partner.

Overview

About Gypsum-based sprayed fireproofing

Gypsum-based SFRMs are sprayed onto clean steel and decks; thickness and density are set by the listed design or tested data for each member and rating.

They are for dry interior conditions – humidity, weather and impact need cementitious or high-density products.

Thickness and density are checked in place to ASTM E605 and bond to ASTM E736.

Key benefits

  • Light weight on the structure
  • Fast application on large areas
  • Covers complex connections
  • Economical for long ratings

World Steel · building envelope hub

How we use Gypsum-based sprayed fireproofing in steel buildings

World Steel coordinates surface preparation and primer compatibility with the sprayed system.

Product-specific test reports, classification reports and certificates are supplied for the product selected for each project – this page describes the product type, not a certified product.

  • 01Specified with the structure – thickness, density and facing matched to the roof, wall and fire design.
  • 02Quantities taken from the same 3D model as the steel, purlins and cladding.
  • 03Packed and shipped with the steel package – one delivery schedule to site.

Applications

Where Gypsum-based sprayed fireproofing is used

  • Concealed beams and columns in offices
  • Steel decks above ceilings
  • Commercial high-rise frames

Technical data

Gypsum-based sprayed fireproofing – technical properties

Typical properties and standards

PropertyUnitValue
Test methods—ASTM E605 · ASTM E736 · UL 263 / ASTM E119 · EN 13381-4
Exposure—Interior, dry, not exposed to impact

Values as published by the manufacturer for this market. Always check the current data sheet and the approvals required for your project before ordering.

FAQ

Frequently asked questions

Is gypsum-based spray suitable for exposed steel?

No – it is for concealed, dry interior steel. Exposed or humid areas need cementitious or high-density systems.

Is this product certified?

Certification belongs to a specific manufacturer’s product or tested system. We supply the test report, classification or listing accepted in your market for the product selected – it is confirmed per project, never assumed.

One partner for structure and envelope

Send us your drawings or bill of quantities – we quote the steel, insulation, boards and ceilings together and ship them as one package.

Request a quotation +84 902 881 833