Fire protection systems compared (illustration)

Two different principles

Intumescent coatings are thin films that expand in a fire. Cementitious fireproofing (sprayed fire-resistive materials, SFRM) is a thick layer of cement or gypsum with light aggregates that insulates from the start.

Comparison

Intumescent vs cementitious
CriterionIntumescentCementitious (SFRM)
AppearanceSmooth, paint-like, any colourTextured – usually concealed
Typical ratings30–120 min (epoxy longer)1–4 h
WeightNegligibleAdds load
ApplicationShop or site, airless spraySite, wet spray
DurabilityGood with topcoat; epoxy very goodLow-density grades fragile; dense grades robust
Cost at long ratingsRises steeplyUsually the lowest
InspectionDFT gaugesThickness and density (ASTM E605)

How to choose

  • Exposed, architectural steel → intumescent.
  • Concealed steel above ceilings, long ratings → cementitious.
  • Export steel that should arrive protected → shop-applied intumescent.
  • Hydrocarbon fires → epoxy intumescent or dense cementitious systems tested for them.

Most projects combine both – and boards for columns in public areas.

FAQ

Which is cheaper?

For short ratings on heavy sections intumescent can be competitive; for long ratings on concealed steel cementitious is usually cheaper.

¿Necesita el espesor y el costo para su proyecto?Envíe la lista de elementos y las clasificaciones de resistencia al fuego – nuestros ingenieros preparan una propuesta de protección contra incendios.