Costruire fiducia, garantire il successo Area clienti dang.victor@worldsteelgroup.com +84 902 881 833
World SteelBuilding trust, Assuring success

WS steel doors, frames & roll-up doors

WS hollow metal doors & frames

Commercial hollow metal doors and frames in 20, 18 and 16 gauge galvannealed steel – insulated cores, fire-rated to 3 hours, prepared for any hardware.

Stati UnitiAustralia / NZEuropa

Richiedi un preventivo Specifiche

  • Galvannealed 20 / 18 / 16 gauge faces
  • Polystyrene or polyurethane core
  • Labelled 20 min – 3 h fire ratings
  • 7 ga hinge, 12 ga closer reinforcement
  • Non-handed leaf, square seamed edges
  • Knock-down or welded 16 / 14 ga frames

What it is

A hollow metal door is two steel face sheets bonded to an insulating core, closed with welded steel channels and reinforced for hinges, locks and closers. It hangs in a pressed steel frame anchored to the wall – the standard opening for factories, warehouses, schools, hospitals, offices and apartment buildings.

World Steel supplies the complete opening: door, frame, anchors and the hardware set, prepared and reinforced to the same schedule so it installs without site cutting. Doors and frames ship with the steel building or as a stand-alone package.

Anatomy of a WS hollow metal door
Galvannealed faces, insulated core, inverted channels and internal reinforcements.

Why galvannealed steel

Galvannealed sheet is zinc-coated steel annealed at a higher temperature, so the zinc and iron combine into a zinc-iron alloy layer. It is harder than ordinary galvanizing, welds cleanly and has a matte surface that takes paint far better – the reason it is the standard for commercial doors.

  • A40 coating (A60 for coastal or high-humidity sites)
  • Cleaned inside and out before priming
  • Baked-on rust-inhibitive primer, ready for the final colour

Construction

Door construction
ElementWS standard
Faces18 or 20 gauge galvannealed (16 gauge for extra-heavy duty)
Thickness1¾ in (45 mm)
CorePolystyrene 1.0 lb/ft³ – R 7.1, U 0.14 · polyurethane 2.0 lb/ft³ – R 11.0, U 0.091 · steel-stiffened
EdgesSquare vertical edges with mechanical interlocking seam, no face seams
Top & bottom16 gauge inverted channels, steel top cap installed
Hinge reinforcement7 gauge (3/16 in), universal 4½ in prep for standard or heavy-weight hinges
LockReinforced 161 cylindrical prep; 86 mortise, exit device and deadbolt preps
Closer12 gauge reinforcement both sides
Max. sizeSingle 4'0" × 8'0" · pair 8'0" × 8'0"
Hinge and lock locations
Standard hinge and lock locations for 6'8", 7'0" and 8'0" doors.

Duty levels

Usage frequency per ANSI/SDI A250.8
Face sheetDuty levelTypical useFrame
16 gaugeExtra-heavy dutyPlant rooms, stairs, high-traffic exterior16 or 14 gauge
18 gaugeHeavy dutyExterior and corridor doors, factories16 gauge
20 gaugeStandard dutyOffices, apartments, interior rooms16 gauge

Wind-rated assemblies for hurricane regions and doors with glass lites, louvres, astragals and electrified hardware preparations are available on request.

Fire-rated openings

Labelled doors and frames are available from 20 minutes to 3 hours, tested to positive-pressure fire standards. The label applies to the assembly – door, frame, hinges, latching hardware and closer – so we supply rated openings as complete sets with the matching listed hardware.

A fire door is only as good as its installation: frames anchored to the wall type, clearances within limits and self-closing, positive-latching hardware.

Norme e requisiti per mercato

I codici secondo cui World Steel progetta, fabbrica e documenta questo prodotto, con i principali requisiti geometrici e di carico in ciascun mercato.

Stati Uniti

  • ANSI/SDI A250.8Standard steel doors and frames (SDI-100)
  • ANSI/SDI A250.6Hardware reinforcings on steel doors and frames
  • ANSI/DHI A115 seriesHardware preparation in steel doors and frames
  • ASTM A653 / A924Galvannealed steel sheet A40 / A60
  • NFPA 80 · UL 10CFire doors – installation and positive-pressure fire test
Fire label
20 min to 3 h on a labelled door and frame
Accessibility
ADA / ICC A117.1 – threshold rise ≤ ½ in
Tutte le norme United States →

Australia / NZ

  • AS 1905.1Fire-resistant doorsets
  • AS 1530.4Fire-resistance tests of elements
  • NCC Volume OneEgress, fire separation and access
  • AS 1428.1Design for access – door circulation and hardware
Fire doorset
door, frame and hardware tested as one assembly
Tutte le norme Australia & New Zealand →

Europa

  • EN 14351-1Windows and external pedestrian doorsets – CE marking
  • EN 16034Fire and smoke resisting doorsets – CE marking
  • EN 1634-1Fire resistance test for doorsets
  • EN 1192Doors – classification of strength requirements
CE marking
Declaration of performance for each doorset type
Tutte le norme Europe →

Sintesi solo orientativa: prevalgono il capitolato di progetto, l'edizione del codice adottata e l'autorità competente.

Finiture

FinituraNorme / note
Prime coatBaked-on rust-inhibitive primer to ANSI A250.10 – primer gray standard
Factory coloursLight gray, bronze, true white, bright white, off white
Field finishPrimer accepts alkyd, acrylic or polyurethane topcoats

Domande frequenti

What is the difference between galvanized and galvannealed doors?

Galvannealed steel is annealed after coating so the zinc alloys with the iron. The surface is harder, welds cleanly and holds paint better, which is why it is the standard for commercial hollow metal doors.

Which gauge do I need?

18 gauge suits most exterior and corridor doors; 16 gauge is for heavy-traffic and abuse-prone openings; 20 gauge is fine for interior rooms with moderate use.

Are the doors handed?

The leaves are non-handed with square edges, so one door fits a left or right hand opening. Frames are prepared for the hand you order.

Prossimo progetto

Progettate una struttura in acciaio all'estero?

Inviateci i vostri disegni o il modello IFC – il nostro ufficio preventivi risponde con ambito di fabbricazione, tempistiche e prezzo reso a destino.