Construyendo confianza, asegurando el éxito Portal de clientes dang.victor@worldsteelgroup.com +84 902 881 833
World SteelBuilding trust, Assuring success

Frame systems

Single-slope buildings

Single-slope PEB frames have a mono-pitch roof draining to one side. Typical spans, slopes, high and low eave heights, uses and design limits explained.

Actualizado 3 min de lectura Ver en el modelo 3D →

Single-slope PEB with a mono-pitch roof rising from a low sidewall to a high sidewall
A single-slope frame drains the whole roof to one sidewall.

What a single-slope frame is

A single-slope (SS) or mono-slope building has a roof that falls in one direction from a high sidewall to a low sidewall. The frame is a rigid frame like a clear-span frame, but the two columns have different heights and the rafter is a single member sloping across the full width. It can be clear-span or have interior columns, in which case it is called a single-slope multi-span frame.

Because all water drains to one side, only one eave gutter and one set of downspouts are needed, and the high wall can carry signage, glazing or clerestory windows. The simple roof geometry also means fewer ridge and hip flashings, which reduces the number of potential leak points compared with gable or multi-gable roofs.

PEB frame types including single-slope frame with high and low eaves
Single-slope frames among the common PEB frame types.

Typical dimensions

Typical single-slope PEB parameters
ParameterCommon rangeComment
Clear span10–40 mWider with interior columns
Roof slope1:20 to 1:10Low slopes keep the high eave reasonable
Low eave height4–10 mSet by clearance needs at the low side
High eave heightLow eave + slope × widthe.g. 30 m at 1:20 adds 1.5 m
Bay spacing6–9 mSame as gable buildings

When to choose a single slope

  • Adjacent buildings. Draining away from a neighbouring building or boundary avoids valley gutters and snow drift problems at the junction.
  • Retail and showrooms. A tall front wall gives an architectural façade and space for signage; see showrooms and commercial buildings.
  • Narrow buildings such as workshops, carports, storage sheds and site offices.
  • Solar roofs. A single plane oriented towards the sun suits photovoltaic arrays, subject to checking the added dead and wind loads.
  • Rainwater harvesting into one collection line.
  • Canopies and covered walkways where a simple roof plane draining away from the main entrance is preferred.

Design considerations and limits

A single-slope frame is unsymmetrical, so its behaviour differs from a gable frame in several ways:

  • Sway under gravity. Unequal column heights cause the frame to sway sideways even under vertical load, which must be included in drift checks.
  • Height grows with width. On wide buildings, the high eave becomes tall, increasing wind area, wall cladding and column size. Above about 40 m width, a gable or multi-span frame is usually more economical.
  • Drainage concentration. All roof water reaches one gutter, so gutter and downspout capacity must be checked for the full roof area; see gutters and downspouts.
  • Snow. Snow sliding to the low side and drift against higher adjacent structures must be considered in cold climates.
  • Wind. Mono-slope roofs have their own pressure coefficients in ASCE 7, AS/NZS 1170.2 and EN 1991-1-4, which differ from gable roofs.

For a single-slope extension built against an existing building, the existing columns usually cannot take new loads. A free-standing single-slope frame, or a lean-to designed with the original building, avoids that problem.

Single-slope variants

Common single-slope configurations
VariantDescriptionNotes
Clear-span single slopeTwo columns of different heights, one sloping rafterMost common up to about 30–40 m width
Single-slope multi-spanOne or more pinned interior columns under a continuous sloping rafterWider buildings while keeping a one-way roof
Single slope with lean-toA lean-to added at the low or high sideAt the high side the lean-to drains towards the main building – check gutter or valley
Near-flat roof with parapetsVery low slope (about 1:50 to 1:24) hidden behind parapetsNeeds standing seam roof, box or internal gutters and ponding checks
Steel roof on concrete or masonrySloping rafters supported on non-steel walls or columnsSee steel roof systems on concrete structures

At the endwalls the rafter and rake trim follow one slope, so endwall posts have different lengths across the wall and the gable is a single triangle; door and window heights near the low eave should be checked early.

Normas por región

RegiónNormaAlcance
United States ASCE 7-22 Chapter 27–30Wind pressures for monoslope roofs
Canada NBC 2020 Part 4Wind and snow loads
Australia / NZ AS/NZS 1170.2:2021Wind actions
Europe EN 1991-1-4Wind actions – monopitch roofs

Preguntas frecuentes

What slope is used for a single-slope PEB?

Typically 1:20 to 1:10. Low slopes keep the high wall height reasonable on wider buildings; standing seam roofing suits the lower end of the range.

Is a single-slope building more expensive than a gable building?

For narrow buildings the difference is small. On wide buildings the tall high-side wall and unsymmetrical frame usually make a gable frame more economical.

Can a single-slope building carry solar panels?

Yes. The frame and purlins are designed for the panel dead load and the changed wind pressures, and the roof sheeting and clamps must be compatible.

Próximo proyecto

¿Planea una estructura metálica en el extranjero?

Envíenos sus planos o su modelo IFC – nuestro equipo de presupuestos responde con el alcance de fabricación, el plazo y el precio puesto en destino.