Costruire fiducia, garantire il successo Area clienti dang.victor@worldsteelgroup.com +84 902 881 833
World SteelBuilding trust, Assuring success

WS modular handrail systems · Handrail systems · WS-MH-400

Free-standing roof-edge guardrail

Non-penetrating counterweighted steel guardrail for flat roofs – protects plant access without drilling the roof; modular, galvanized, AS 1657 / EN ISO 14122-3.

Stati UnitiAustralia / NZEuropa

Richiedi un preventivo Specifiche

  • No drilling through the roof membrane
  • Counterweighted base arms with struts
  • Straight runs, corners and gate openings
  • Same rails and fittings as the WS system
  • Galvanized for exposed roofs

What it is

The WS-MH-400 free-standing guardrail protects the edges of flat roofs, roof plant areas and walkways to equipment without penetrating the roof. Each stanchion sits on a steel base arm that lies on the roof surface, braced by an inclined strut and held by counterweights; protective pads stop the base from damaging the membrane.

It is typically added to roof platforms and catwalks, logistics and industrial roofs with HVAC and solar plant, and to existing buildings where a parapet is too low.

Diagram of guardrail heights in the US, Australia and Europe
Guardrail heights by region set the fitting positions on every WS stanchion.

Types and options

Free-standing configurations
CodeConfigurationTypical use
WS-MH-410Straight run, counterweighted armsRoof edges and walkways
WS-MH-420Corner and return modulesRoof corners and plant enclosures
WS-MH-430Gate and access moduleRoof hatches and ladder arrivals
WS-MH-440Folding (collapsible) versionWhere rails must be invisible from the street

Design and compliance

A free-standing guardrail resists the barrier load by counterweight and friction rather than by fixings, so the number of weights, the arm length and the stability are checked for the code load, the roof slope and the roof surface. Permanent installations follow AS 1657 in Australia, EN ISO 14122-3 in Europe and OSHA 1910.29 in the US; the roof’s capacity for the counterweights is confirmed with the building engineer.

In wind-exposed and cyclonic regions additional ballast or a fixed system may be required; World Steel advises per project.

Installation and selection

  • Place the base arms with their protective pads at the set spacing from the roof edge.
  • Fit stanchions, struts and rails, then place the counterweights.
  • Check the run for stability and alignment, and fit gates at access points.
  • Specify roof type, edge height, wind region and the plant to be accessed.

Fabrication and finishing at World Steel

Every WS modular handrail component is made in the World Steel plant in Vietnam: tube and bar are cut on saws to the component schedule, stanchions are welded to base plates, brackets or socket spigots on jigs so that rail heights repeat exactly, and fittings are fabricated from heavy-wall tube and plate, drilled and tapped for their locking screws. Welding follows qualified procedures under ISO 3834-2 and the AS/NZS 5131 and EN 1090-2 systems our certifications cover.

Components are then hot-dip galvanized as single pieces – which is only possible because the system is modular – giving full internal and external zinc coverage with no site welds to repair afterwards. A safety-yellow or architectural topcoat can follow. Parts are marked with their WS code, bagged by type and packed by area for export shipping, together with the structural steel or on their own.

Norme e requisiti per mercato

I codici secondo cui World Steel progetta, fabbrica e documenta questo prodotto, con i principali requisiti geometrici e di carico in ciascun mercato.

Stati Uniti

  • OSHA 29 CFR 1910.29Fall protection systems – guardrails
  • ASCE 7Minimum design loads – guard systems
  • IBCInternational Building Code – guards
  • ASTM A123Hot-dip galvanized coatings
Top rail height
42 in ± 3 in (OSHA 1910.29(b))
Rail loads
Top 200 lbf, mid 150 lbf (OSHA 1910.29(b))
Max opening
19 in (OSHA 1910.29(b))
Tutte le norme United States →

Australia / NZ

  • AS 1657-2018Fixed platforms, walkways, stairways and ladders
  • AS/NZS 1170.1Imposed actions – barrier loads
  • AS/NZS 5131 Certificata WSCFabrication and erection of structural steelwork
  • AS/NZS 4680Hot-dip galvanized coatings
Guardrail height
900–1100 mm (AS 1657)
Toe board
≥ 100 mm where required (AS 1657)
Tutte le norme Australia & New Zealand →

Europa

  • EN ISO 14122-3Stairs, stepladders and guard-rails
  • EN 1991-1-1Imposed loads – barriers
  • EN 1090-2 Certificata WSCExecution of steel structures
  • EN ISO 1461Hot-dip galvanized coatings
Guard-rail height
≥ 1100 mm (EN ISO 14122-3)
Rail gaps
≤ 500 mm (EN ISO 14122-3)
Toe-plate
≥ 100 mm (EN ISO 14122-3)
Tutte le norme Europe →

Sintesi solo orientativa: prevalgono il capitolato di progetto, l'edizione del codice adottata e l'autorità competente.

Finiture

FinituraNorme / note
Hot-dip galvanized (standard)ASTM A123 / A153 · AS/NZS 4680 · EN ISO 1461
Duplex – HDG + safety-yellow topcoatASTM A123 + topcoat · AS/NZS 4680 + AS/NZS 2312.1 · EN ISO 1461 + EN ISO 12944
HDG + powder coat (architectural colours)Galvanized, then polyester powder coat for visible public areas

Domande frequenti

Does the roof need to be drilled?

No. The guardrail is held by counterweights on base arms that lie on the roof surface with protective pads.

Can it be used on sloping roofs?

Only on flat and low-slope roofs within the tested stability range; for steeper roofs we propose a fixed system.

Is it permanent or temporary?

WS-MH-400 is designed as permanent edge protection for maintenance access. Temporary construction edge protection follows different standards.

Prossimo progetto

Progettate una struttura in acciaio all'estero?

Inviateci i vostri disegni o il modello IFC – il nostro ufficio preventivi risponde con ambito di fabbricazione, tempistiche e prezzo reso a destino.