Costruire fiducia, garantire il successo Area clienti dang.victor@worldsteelgroup.com +84 902 881 833
World SteelBuilding trust, Assuring success

Sandwich panels & floor decking

WS steel floor decking

WS composite floor decking 50 and 75 mm deep, 0.58–1.60 mm thick – permanent formwork and tension reinforcement for composite slabs on steel beams and mezzanines.

Stati UnitiAustralia / NZEuropa

Richiedi un preventivo Specifiche

  • Two profiles: WS 1000-50-3 and WS 900-75-3
  • Thickness 0.58–1.60 mm, G300–450
  • Acts as formwork and reinforcement
  • Embossed webs for composite action

Formwork and reinforcement in one

Steel decking is laid on the beams as a working platform, carries the wet concrete as permanent formwork and then works with the slab as tension reinforcement. With shear studs welded through to the beams, deck, slab and beams act compositely – lighter floors and faster construction for multi-storey buildings and mezzanines.

WS floor deck profiles 50 and 75 mm
WS decking profiles with slab outline.

Profiles and technical data

WS floor decking
CodeCover (mm)Coil width (mm)Rib (mm)Thickness (mm)Yield
WS 1000-50-310001200500.58–1.50G300–450
WS 900-75-39001200750.75–1.60G300–450

Unpropped spans and slab capacities depend on deck thickness, slab depth and loads – ask for the span tables for your design code.

Norme e requisiti per mercato

I codici secondo cui World Steel progetta, fabbrica e documenta questo prodotto, con i principali requisiti geometrici e di carico in ciascun mercato.

Stati Uniti

  • SDI C / SDI RDComposite and roof deck standards
  • ASTM A653Galvanized structural sheet
  • AWS D1.3Welding of sheet steel
Tutte le norme United States →

Australia / NZ

  • AS/NZS 2327Composite structures
  • AS 1397Metallic-coated steel sheet
  • AS/NZS 4600Cold-formed steel structures
Tutte le norme Australia & New Zealand →

Europa

  • EN 1994-1-1Composite steel and concrete structures
  • EN 1993-1-3Cold-formed members and sheeting
  • EN 10346Hot-dip coated steel
Tutte le norme Europe →

Sintesi solo orientativa: prevalgono il capitolato di progetto, l'edizione del codice adottata e l'autorità competente.

Finiture

FinituraNorme / note
GalvanizedZ180–Z275

Domande frequenti

Does the deck need props?

Up to the unpropped span for the chosen deck and slab no props are needed; longer spans need temporary propping during concreting.

Prossimo progetto

Progettate una struttura in acciaio all'estero?

Inviateci i vostri disegni o il modello IFC – il nostro ufficio preventivi risponde con ambito di fabbricazione, tempistiche e prezzo reso a destino.