WS standing seam roof sheets (Seamlock)

WS Seamlock standing seam roof sheets – concealed clips, mechanically seamed ribs, 470–1040 mm cover and 60–82 mm ribs for long, low-slope industrial roofs.

Stati UnitiAustralia / NZEuropa

Richiedi un preventivo Specifiche

  • Five profiles: WS 1000-81-3, 1040-70-3, 500-60-2, 485-65-2, 470-81-2
  • Concealed clips – no through-fasteners in the roof sheet
  • Seams closed on site with a seaming machine, sealant in the lap
  • Allows thermal movement of long sheets
  • Base metal 0.47–0.60 mm, G300–450

How a standing seam roof works

A standing seam roof has no screws through the sheet. Each sheet is held by concealed clips fixed to the purlins; the side laps of neighbouring sheets are rolled together into a continuous seam with a portable seaming machine, and sealant is injected into the lap. The roof becomes one watertight membrane that can slide on its clips as it expands and contracts.

This makes standing seam the preferred roof for long sheets, low slopes and large industrial and logistics buildings – see our standing seam roof systems article.

Five WS standing seam roof profiles with cover widths and rib heights
WS Seamlock profiles – cover width and rib height in mm.

Profiles and technical data

WS standing seam roof sheets
CodeCover (mm)Coil width (mm)Rib (mm)Thickness (mm)YieldUse
WS 1000-81-310001200820.47–0.60G300–450Roof
WS 1040-70-310401200700.47–0.60G300–450Roof
WS 500-60-2500598600.47–0.60G300–450Roof
WS 485-65-24851200650.47–0.60G300–450Roof
WS 470-81-2470595800.47–0.60G300–450Roof

The 1000 and 1040 mm profiles have a centre rib and two pans; the 470–500 mm profiles are single-pan sheets for the most demanding wind areas.

Installation sequence

  • Fix the clips to the purlins along the first sheet line
  • Lay the sheet, engage the next clip row and the next sheet
  • Pre-crimp, then close the seam with the seaming machine
  • Inject sealant in the lap where specified; fix ridge and eave closures and flashings

Clip spacing follows the purlin spacing and the wind design. Use the matching WS clip for each profile – clips are not interchangeable between profiles.

Norme e requisiti per mercato

I codici secondo cui World Steel progetta, fabbrica e documenta questo prodotto, con i principali requisiti geometrici e di carico in ciascun mercato.

Stati Uniti

  • ASTM A653 / A792Galvanized / 55 % Al-Zn coated sheet
  • ASTM A755Coil-coated (pre-painted) metallic-coated sheet
  • AISI S100Cold-formed steel design
  • ASTM E1592 · UL 580Wind uplift testing of roof panels
Tutte le norme United States →

Australia / NZ

  • AS 1397Metallic-coated steel sheet – G300 to G550, Z / AZ coatings
  • AS/NZS 2728Pre-finished / pre-painted sheet
  • AS 1562.1Design and installation of metal roof and wall cladding
  • AS 4040Methods of testing sheet roof and wall cladding (incl. cyclonic)
Tutte le norme Australia & New Zealand →

Europa

  • EN 10346Continuously hot-dip coated steel flat products
  • EN 10169Organic coated (pre-painted) steel flat products
  • EN 14782Self-supporting metal sheet for roofing and cladding – CE marking
  • EN 1993-1-3Cold-formed members and sheeting
Tutte le norme Europe →

Sintesi solo orientativa: prevalgono il capitolato di progetto, l'edizione del codice adottata e l'autorità competente.

Finiture

FinituraNorme / note
Zinc-aluminium (AZ) coatedAZ100–AZ150 · AS 1397 / ASTM A792 / EN 10346
Galvanized (Z)Z180–Z275 · AS 1397 / ASTM A653 / EN 10346
Pre-paintedPolyester or SMP paint system on AZ / Z substrate · AS/NZS 2728 / ASTM A755 / EN 10169
ColoursStandard colour range; special colours on minimum order quantity

Domande frequenti

Why choose standing seam instead of screw-fixed sheets?

There are no fastener holes in the roof sheet, the seam is continuous and the sheet can move on its clips – a more watertight roof for long sheets and low slopes.

Which profile should I use?

Wide 1000 / 1040 mm profiles cover faster; narrow 470–500 mm single-pan profiles give more clips per square metre for high wind areas. The choice follows the wind design and purlin spacing.

Do you supply the seaming machine?

Seaming is done on site with a portable seaming machine; it can be provided with installation supervision on request.

Prossimo progetto

Progettate una struttura in acciaio all'estero?

Inviateci i vostri disegni o il modello IFC – il nostro ufficio preventivi risponde con ambito di fabbricazione, tempistiche e prezzo reso a destino.