Switchback and egress stairs

Switchback and multi-storey egress stairs in steel – flights, landings, rails and towers fabricated to IBC/OSHA, NCC/AS 1657 and EN rules for export.

미국호주 / 뉴질랜드유럽

견적 요청 사양

  • Two-flight and multi-storey switchback stairs and stair towers
  • Egress geometry to IBC, NCC or national EU building rules
  • Landings, stringers, rails and support columns in one package
  • Seismic and egress requirements coordinated with the designer
  • CE marking to EN 1090-1 for the EU; AS/NZS 5131 CC3 for AU
  • Shipped as bolted flights and landings with an IFC model

What it is

A switchback stair (also called a dog-leg or U-return stair) rises in two or more flights that turn 180° at intermediate landings. It reaches the same height as a straight stair in roughly half the length, which makes it the standard layout for egress stairs in buildings, external fire escapes, multi-level platforms and free-standing stair towers serving tanks, silos, conveyors and equipment structures.

Egress stairs form part of the means of escape of a building, so their geometry, width, rails and fire protection are set by the building code rather than by plant-access rules. World Steel details and fabricates the steel – stringers, landings, posts, rails and stair tower frames – to the code basis and fire strategy given by the project designer.

Types and options

Switchback and egress stair configurations
ConfigurationDescriptionTypical use
Two-flight switchbackTwo flights, one intermediate landingMezzanines, single-level platforms with limited run
Multi-storey stairRepeating flights and landings floor to floorEgress stairs inside steel-framed buildings
External fire escapeOpen stair fixed to the building facadeSecondary egress, retrofits
Free-standing stair towerStair with its own columns and bracingTanks, silos, conveyors, plant structures
Scissor stairTwo interlocking stairs in one shaftBuildings needing two separate exits in a small core

Treads can be grating treads for external and industrial stairs, or concrete-filled pan treads and landings for internal egress stairs, which are quieter and accept floor finishes. Rails range from industrial pipe rails to architectural balustrades with picket or glass infill.

Design and compliance

Stair geometry limits for egress and access stairs by region
Stair geometry limits by region – egress stairs in buildings use the building code values.
  • United States (IBC 2021): riser 4–7 in, tread ≥ 11 in, width ≥ 44 in (36 in where the occupant load is below 50), headroom ≥ 80 in, and a flight may not rise more than 12 ft (3,658 mm) between landings. Handrails 34–38 in with a circular Type I profile of 1¼–2 in diameter; guards ≥ 42 in with openings that reject a 4 in sphere (21 in in industrial areas not open to the public). Egress stairs are nonstructural components under ASCE 7 Chapter 13 and must accommodate storey drift where the building is seismic.
  • US workplaces (OSHA 1910.25): angle 30°–50°, riser ≤ 9.5 in, tread ≥ 9.5 in, width ≥ 22 in; stair rails installed since 17 January 2017 need a top rail of at least 42 in.
  • Australia (NCC 2022): riser 115–190 mm, going 250–355 mm, 2R + G 550–700 mm, not more than 18 or fewer than 2 risers per flight; barriers ≥ 1000 mm (≥ 865 mm along the stair) with openings that reject a 125 mm sphere; handrails ≥ 865 mm. Plant-access stairs follow AS 1657.
  • Europe: stairs in buildings follow national building regulations, with barrier loads from EN 1991-1-1 Table 6.12 and seismic actions from EN 1998 where relevant; machinery-access stairs follow EN ISO 14122-3 (angle 20°–45°, 600 mm ≤ g + 2h ≤ 660 mm, guard-rail ≥ 1100 mm).
Guard and handrail heights for stairs by region
Guard and handrail heights by region, including the lower handrail height along stair flights.

Fire protection of egress stair steel, where required, is part of the fire strategy – see structural fire protection. Seismic detailing of slip connections and landing supports is coordinated with the building designer through seismic design inputs.

Fabrication and finishing at World Steel

Flights and landings are fabricated as separate bolted units so that a multi-storey stair can be packed into containers and erected floor by floor. Stringers are CNC-drilled for treads and connections; landing frames, posts and rail returns are welded in jigs so that the handrail runs continuously from flight to landing to flight. Welding follows AWS D1.1, AS/NZS 1554.1 or EN 1090-2 / EN ISO 3834-2 procedures. Where specified, a complete flight-landing-flight set is trial-assembled to check rise, rail continuity and the slip connections. Finishes are hot-dip galvanizing by qualified galvanizers to ASTM A123, AS/NZS 4680 or EN ISO 1461, or paint to the project system.

Installation and specifying

Erect the landing supports first, then lift each flight with its stringers braced, bolt to the landings and install rails as each level is completed so the stair can be used safely during construction. Leave slotted seismic connections un-tightened as detailed. For a quotation, send floor levels, available footprint, code basis, occupant load or required width, tread and rail type, fire and seismic requirements and finish – see the quotation process.

시장별 표준 및 요구사항

World Steel이 본 제품의 설계, 제작, 문서화에 적용하는 기준 – 그리고 각 시장의 주요 형상 및 하중 요구사항.

미국

  • IBC 2021 §1011Stairways
  • IBC 2021 §1014 / §1015Handrails and guards
  • ASCE 7 Ch. 13Nonstructural components incl. egress stairs
  • OSHA 1910.25 / 1910.29Stairways; handrails and stair rails
  • NAAMM AMP 510Metal Stairs Manual
  • AWS D1.1Structural welding code – steel
Riser / tread
4–7 in / ≥ 11 in (IBC 1011.5.2)
Stair width
≥ 44 in; 36 in where occupant load < 50 (IBC 2021)
Handrails
34–38 in, Type I 1¼–2 in OD (IBC 1014.2, 1014.3.1)
Guards
≥ 42 in, 4 in sphere rule (IBC 1015.3, 1015.4)
United States 표준 전체 →

호주 / 뉴질랜드

  • NCC 2022 Vol. 1Stairs, barriers and handrails
  • AS 1657-2018Fixed platforms, walkways, stairways and ladders
  • AS 1428.1Design for access and mobility
  • AS/NZS 1170.1 / AS 1170.4Imposed actions; earthquake actions
  • AS/NZS 5131 WSC 인증 보유Fabrication and erection of structural steelwork
Riser / going
115–190 mm / 250–355 mm, 2R + G 550–700 mm (NCC 2022)
Barrier height
≥ 1000 mm; ≥ 865 mm along stairs (NCC 2022)
Barrier openings
Must not pass a 125 mm sphere (NCC 2022)
Handrails (accessible)
865–1000 mm, 30–50 mm diameter (AS 1428.1)
Australia & New Zealand 표준 전체 →

유럽

  • EN 1991-1-1Imposed loads (Table 6.12 barrier loads)
  • EN 1998Design of structures for earthquake resistance
  • EN ISO 14122-3Stairs and guard-rails (machinery access)
  • EN 1090-1 / EN 1090-2CE marking and execution of steel structures
  • EN ISO 3834-2Quality requirements for fusion welding
Building stairs
Geometry per national building regulations
Machinery-access stairs
20°–45°, 600 mm ≤ g + 2h ≤ 660 mm (EN ISO 14122-3)
Guard-rail (machinery access)
≥ 1100 mm with knee-rail and toe-plate (EN ISO 14122-3)
Europe 표준 전체 →

참고용 요약입니다 – 프로젝트 시방서, 채택된 기준 판본 및 관할 기관의 요구가 우선합니다.

표면 처리

표면 처리표준 / 비고
Hot-dip galvanizedASTM A123 · AS/NZS 4680 · EN ISO 1461
PaintedSSPC-SP 6 / SP 10 · AS/NZS 2312.1 · EN ISO 12944
Duplex (galvanized + paint)ASTM A123 + paint · AS/NZS 2312.2 + 2312.1 · EN ISO 1461 + EN ISO 12944

자주 묻는 질문

What is the difference between an access stair and an egress stair?

An access stair serves plant or maintenance areas and follows workplace rules such as OSHA 1910, AS 1657 or EN ISO 14122-3. An egress stair is part of a building's escape route and follows the building code – IBC, NCC or national regulations – which usually requires lower risers, deeper treads, wider flights and stricter guard openings.

Can you supply a complete free-standing stair tower?

Yes. World Steel fabricates the tower columns, bracing, landings, flights and rails as one package, with base plates and anchor bolt templates.

How are multi-storey stairs shipped?

As bolted flights and landings marked by level, packed in containers or on flat racks, with an erection drawing and IFC model.

Do egress stairs need seismic detailing?

In seismic regions, egress stairs must accommodate storey drift (for example under ASCE 7 Chapter 13). The designer specifies the connection details, and World Steel fabricates slotted or sliding connections to suit.

다음 프로젝트

해외 철골 구조물을 계획 중이십니까?

도면 또는 IFC 모델을 보내주십시오. 견적팀이 제작 범위, 일정 및 인도 가격을 회신해 드립니다.