Fire curtains · active barriers
Automatic fire curtains
A fire-resistant fabric barrier hidden in a slim head box, deployed by gravity when the fire alarm triggers.
- Fire-resistant fabric
- Barrier
- Fire alarm, gravity fail-safe
- Activation
- E / EW per test
- Rating
Fornecido pela World Steel com seu edifício metálico ou separadamente – um pedido, um embarque, um parceiro.
Visão geral
Sobre Automatic fire curtains
Fire curtains are active barriers: the fabric is stored in a head box and released by the fire-alarm signal, closing by gravity even on power loss.
They are tested to EN 1634-1 and classified E or EW under EN 13501-2, designed to BS 8524-1 / -2 in the UK and UL 10D in North America; they are integrity barriers and do not insulate like a fire wall.
Regular testing and maintenance are part of the approval – an active system must be shown to work.
Principais benefícios
- Invisible until deployed
- Closes wide openings without columns
- Gravity fail-safe operation
- Interfaces with the fire alarm
World Steel · central de envoltória da edificação
Como usamos Automatic fire curtains em edifícios metálicos
World Steel provides the steel support for curtain head boxes and coordinates the opening with the structure.
Product-specific test reports, classification reports and certificates are supplied for the product selected for each project – this page describes the product type, not a certified product.
- 01Especificado junto com a estrutura – espessura, densidade e revestimento compatíveis com o projeto da cobertura, das paredes e de proteção contra incêndio.
- 02Quantitativos extraídos do mesmo modelo 3D que o aço, as terças e o fechamento.
- 03Embalado e enviado com o pacote de aço – um único cronograma de entrega na obra.
Aplicações
Onde Automatic fire curtains é utilizado
- Atriums and open-plan offices
- Shopping centres and public buildings
- Openings where walls are not possible
Dados técnicos
Automatic fire curtains – propriedades técnicas
Typical properties and standards
| Propriedade | Unidade | Valor |
|---|---|---|
| Fire test | — | EN 1634-1 · UL 10D · AS 1530.4 |
| Design / installation | — | BS 8524-1 / -2 |
| Classification | — | EN 13501-2 – E, EW |
| Activation | — | Fire-alarm interface, gravity fail-safe, battery back-up |
Valores conforme publicados pelo fabricante para este mercado. Sempre verifique a ficha técnica atual e as aprovações exigidas para seu projeto antes de fazer o pedido.
Shutters & curtains
Produtos relacionados
Fire shutters · openingsFire-rated roller shuttersVer produto →
Smoke curtains · smoke controlSmoke curtainsVer produto →
Fire curtains · combinedCombined fire and smoke curtainsVer produto →← Fire shutters, fire curtains and smoke curtainsFire-Rated Building Systems – Panels, Doors, Glazing, Shutters and Curtains →
FAQ
Perguntas frequentes
Is a fire curtain equal to a fire wall?
No – most fire curtains provide integrity (E/EW) only. Whether a curtain is acceptable is decided by the fire engineer and the authority.
Is this product certified?
Certification belongs to a specific manufacturer’s product or tested system. We supply the test report, classification or listing accepted in your market for the product selected – it is confirmed per project, never assumed.
Um único parceiro para estrutura e envoltória
Envie-nos seus desenhos ou planilha de quantitativos – cotamos o aço, o isolamento, as placas e os forros em conjunto e os enviamos como um único pacote.