Smoke curtains · smoke control
Smoke curtains
Smoke kills before heat does – smoke curtains create reservoirs and keep escape routes clear for longer.
- Smoke-resistant fabric
- Barrier
- Static or automatic
- Types
- EN 12101-1
- Standard
Fornecido pela World Steel com seu edifício metálico ou separadamente – um pedido, um embarque, um parceiro.
Visão geral
Sobre Smoke curtains
Smoke barriers limit the spread of smoke under the roof so that smoke exhaust systems can work; they are part of the smoke control strategy set by the fire engineer.
Smoke curtains are tested and classified to EN 12101-1 (classes D and DH for fixed and automatic barriers); in North America smoke control follows NFPA 92 and barrier leakage UL 1784.
Automatic versions deploy on the fire-alarm signal and fail safe by gravity.
Principais benefícios
- Creates smoke reservoirs under roofs
- Keeps escape routes clear longer
- Static or automatic deployment
- Works with smoke exhaust systems
World Steel · central de envoltória da edificação
Como usamos Smoke curtains em edifícios metálicos
World Steel coordinates the steel supports and roof-level fixing of smoke barriers with the structure.
Product-specific test reports, classification reports and certificates are supplied for the product selected for each project – this page describes the product type, not a certified product.
- 01Especificado junto com a estrutura – espessura, densidade e revestimento compatíveis com o projeto da cobertura, das paredes e de proteção contra incêndio.
- 02Quantitativos extraídos do mesmo modelo 3D que o aço, as terças e o fechamento.
- 03Embalado e enviado com o pacote de aço – um único cronograma de entrega na obra.
Aplicações
Onde Smoke curtains é utilizado
- Atriums and malls
- Large warehouses and production halls
- Transport and public buildings
Dados técnicos
Smoke curtains – propriedades técnicas
Typical properties and standards
| Propriedade | Unidade | Valor |
|---|---|---|
| Product standard | — | EN 12101-1 (smoke barriers) |
| Smoke control design | — | EN 12101 series · NFPA 92 · local code |
| Leakage | — | UL 1784 where specified |
| Activation | — | Static, or fire-alarm activated with gravity fail-safe |
Valores conforme publicados pelo fabricante para este mercado. Sempre verifique a ficha técnica atual e as aprovações exigidas para seu projeto antes de fazer o pedido.
Shutters & curtains
Produtos relacionados
Fire shutters · openingsFire-rated roller shuttersVer produto →
Fire curtains · active barriersAutomatic fire curtainsVer produto →
Fire curtains · combinedCombined fire and smoke curtainsVer produto →← Fire shutters, fire curtains and smoke curtainsFire-Rated Building Systems – Panels, Doors, Glazing, Shutters and Curtains →
FAQ
Perguntas frequentes
Does a smoke curtain stop fire?
No – it limits smoke spread. Fire separation needs a fire-rated wall, door, shutter or fire curtain.
Is this product certified?
Certification belongs to a specific manufacturer’s product or tested system. We supply the test report, classification or listing accepted in your market for the product selected – it is confirmed per project, never assumed.
Um único parceiro para estrutura e envoltória
Envie-nos seus desenhos ou planilha de quantitativos – cotamos o aço, o isolamento, as placas e os forros em conjunto e os enviamos como um único pacote.