Fire shutters · openings
Fire-rated roller shutters
Large openings stay open for traffic and close automatically when the fire alarm or a fusible link triggers.
- Steel slats
- Curtain
- Openings in fire walls
- Use
- Per tested shutter
- Rating
Fornecido pela World Steel com seu edifício metálico ou separadamente – um pedido, um embarque, um parceiro.
Visão geral
Sobre Fire-rated roller shutters
Fire shutters are tested to EN 1634-1 and classified under EN 13501-2 (usually E or EW; EI needs insulated curtains), to UL 10B / NFPA 80 in North America and to AS 1530.4 with AS 1905.2 in Australia.
Release is by fire-alarm signal, fusible link or both, with gravity or motorised fail-safe closing; the opening must be kept clear of obstructions.
The shutter, guides and head box are fixed to the steel framing of the opening, which must itself be fire-protected for the rating.
Principais benefícios
- Closes large openings automatically
- Fail-safe release on alarm or fusible link
- Steel slats, guides and coil box
- Tested with the wall type
World Steel · central de envoltória da edificação
Como usamos Fire-rated roller shutters em edifícios metálicos
World Steel designs the steel framing around shutter openings and protects it for the same fire rating.
Product-specific test reports, classification reports and certificates are supplied for the product selected for each project – this page describes the product type, not a certified product.
- 01Especificado junto com a estrutura – espessura, densidade e revestimento compatíveis com o projeto da cobertura, das paredes e de proteção contra incêndio.
- 02Quantitativos extraídos do mesmo modelo 3D que o aço, as terças e o fechamento.
- 03Embalado e enviado com o pacote de aço – um único cronograma de entrega na obra.
Aplicações
Onde Fire-rated roller shutters é utilizado
- Conveyor and loading openings in fire walls
- Counters and service hatches
- Warehouse compartment openings
Dados técnicos
Fire-rated roller shutters – propriedades técnicas
Typical properties and standards
| Propriedade | Unidade | Valor |
|---|---|---|
| Fire test | — | EN 1634-1 · UL 10B / NFPA 80 · AS 1530.4 |
| Product standard | — | EN 13241 (industrial doors) · AS 1905.2 (fire-resistant shutters) |
| Classification | — | EN 13501-2 – E, EW, EI |
| Release | — | Fire alarm interface and / or fusible link, fail-safe closing |
Valores conforme publicados pelo fabricante para este mercado. Sempre verifique a ficha técnica atual e as aprovações exigidas para seu projeto antes de fazer o pedido.
Shutters & curtains
Produtos relacionados
Fire curtains · active barriersAutomatic fire curtainsVer produto →
Smoke curtains · smoke controlSmoke curtainsVer produto →
Fire curtains · combinedCombined fire and smoke curtainsVer produto →← Fire shutters, fire curtains and smoke curtainsFire-Rated Building Systems – Panels, Doors, Glazing, Shutters and Curtains →
FAQ
Perguntas frequentes
Does a fire shutter stop heat?
Most shutters are integrity-rated (E or EW); insulated (EI) shutters exist but are thicker – the code decides which class is needed.
Is this product certified?
Certification belongs to a specific manufacturer’s product or tested system. We supply the test report, classification or listing accepted in your market for the product selected – it is confirmed per project, never assumed.
Um único parceiro para estrutura e envoltória
Envie-nos seus desenhos ou planilha de quantitativos – cotamos o aço, o isolamento, as placas e os forros em conjunto e os enviamos como um único pacote.