신뢰 구축, 성공 보장 고객 포털 dang.victor@worldsteelgroup.com +84 902 881 833
World SteelBuilding trust, Assuring success
Fire-rated roller shutters – illustration

제품 이미지: 제조사(공식).

Fire shutters · openings

Fire-rated roller shutters

Large openings stay open for traffic and close automatically when the fire alarm or a fusible link triggers.

Steel slats
Curtain
Openings in fire walls
Use
Per tested shutter
Rating

견적 요청

World Steel이 철골 건축물과 함께 또는 단독으로 공급 – 하나의 주문, 하나의 선적, 하나의 파트너.

개요

Fire-rated roller shutters 소개

Fire shutters are tested to EN 1634-1 and classified under EN 13501-2 (usually E or EW; EI needs insulated curtains), to UL 10B / NFPA 80 in North America and to AS 1530.4 with AS 1905.2 in Australia.

Release is by fire-alarm signal, fusible link or both, with gravity or motorised fail-safe closing; the opening must be kept clear of obstructions.

The shutter, guides and head box are fixed to the steel framing of the opening, which must itself be fire-protected for the rating.

주요 장점

  • Closes large openings automatically
  • Fail-safe release on alarm or fusible link
  • Steel slats, guides and coil box
  • Tested with the wall type

World Steel · 건물 외피 허브

철골 건축물에서의 Fire-rated roller shutters 활용 방식

World Steel designs the steel framing around shutter openings and protects it for the same fire rating.

Product-specific test reports, classification reports and certificates are supplied for the product selected for each project – this page describes the product type, not a certified product.

  • 01구조물과 함께 사양 결정 – 두께, 밀도, 면재를 지붕, 벽 및 내화 설계에 맞춥니다.
  • 02철골, 퍼린, 외장재와 동일한 3D 모델에서 물량을 산출합니다.
  • 03철골 패키지와 함께 포장·선적 – 현장까지 하나의 납품 일정.

용도

Fire-rated roller shutters의 사용처

  • Conveyor and loading openings in fire walls
  • Counters and service hatches
  • Warehouse compartment openings

기술 데이터

Fire-rated roller shutters – 기술 특성

Typical properties and standards

특성단위값
Fire test—EN 1634-1 · UL 10B / NFPA 80 · AS 1530.4
Product standard—EN 13241 (industrial doors) · AS 1905.2 (fire-resistant shutters)
Classification—EN 13501-2 – E, EW, EI
Release—Fire alarm interface and / or fusible link, fail-safe closing

해당 시장용으로 제조사가 공개한 값입니다. 주문 전 항상 최신 데이터 시트와 프로젝트에 필요한 승인 사항을 확인하세요.

FAQ

자주 묻는 질문

Does a fire shutter stop heat?

Most shutters are integrity-rated (E or EW); insulated (EI) shutters exist but are thicker – the code decides which class is needed.

Is this product certified?

Certification belongs to a specific manufacturer’s product or tested system. We supply the test report, classification or listing accepted in your market for the product selected – it is confirmed per project, never assumed.

구조와 외피를 위한 하나의 파트너

도면 또는 물량 내역서를 보내주시면 철골, 단열재, 보드, 천장재를 함께 견적하여 하나의 패키지로 선적합니다.

견적 요청 +84 902 881 833