Fire shutters · openings
Fire-rated roller shutters
Large openings stay open for traffic and close automatically when the fire alarm or a fusible link triggers.
- Steel slats
- Curtain
- Openings in fire walls
- Use
- Per tested shutter
- Rating
World Steel이 철골 건축물과 함께 또는 단독으로 공급 – 하나의 주문, 하나의 선적, 하나의 파트너.
개요
Fire-rated roller shutters 소개
Fire shutters are tested to EN 1634-1 and classified under EN 13501-2 (usually E or EW; EI needs insulated curtains), to UL 10B / NFPA 80 in North America and to AS 1530.4 with AS 1905.2 in Australia.
Release is by fire-alarm signal, fusible link or both, with gravity or motorised fail-safe closing; the opening must be kept clear of obstructions.
The shutter, guides and head box are fixed to the steel framing of the opening, which must itself be fire-protected for the rating.
주요 장점
- Closes large openings automatically
- Fail-safe release on alarm or fusible link
- Steel slats, guides and coil box
- Tested with the wall type
World Steel · 건물 외피 허브
철골 건축물에서의 Fire-rated roller shutters 활용 방식
World Steel designs the steel framing around shutter openings and protects it for the same fire rating.
Product-specific test reports, classification reports and certificates are supplied for the product selected for each project – this page describes the product type, not a certified product.
- 01구조물과 함께 사양 결정 – 두께, 밀도, 면재를 지붕, 벽 및 내화 설계에 맞춥니다.
- 02철골, 퍼린, 외장재와 동일한 3D 모델에서 물량을 산출합니다.
- 03철골 패키지와 함께 포장·선적 – 현장까지 하나의 납품 일정.
용도
Fire-rated roller shutters의 사용처
- Conveyor and loading openings in fire walls
- Counters and service hatches
- Warehouse compartment openings
기술 데이터
Fire-rated roller shutters – 기술 특성
Typical properties and standards
| 특성 | 단위 | 값 |
|---|---|---|
| Fire test | — | EN 1634-1 · UL 10B / NFPA 80 · AS 1530.4 |
| Product standard | — | EN 13241 (industrial doors) · AS 1905.2 (fire-resistant shutters) |
| Classification | — | EN 13501-2 – E, EW, EI |
| Release | — | Fire alarm interface and / or fusible link, fail-safe closing |
해당 시장용으로 제조사가 공개한 값입니다. 주문 전 항상 최신 데이터 시트와 프로젝트에 필요한 승인 사항을 확인하세요.
Shutters & curtains
관련 제품
Fire curtains · active barriersAutomatic fire curtains제품 보기 →
Smoke curtains · smoke controlSmoke curtains제품 보기 →
Fire curtains · combinedCombined fire and smoke curtains제품 보기 →← Fire shutters, fire curtains and smoke curtainsFire-Rated Building Systems – Panels, Doors, Glazing, Shutters and Curtains →
FAQ
자주 묻는 질문
Does a fire shutter stop heat?
Most shutters are integrity-rated (E or EW); insulated (EI) shutters exist but are thicker – the code decides which class is needed.
Is this product certified?
Certification belongs to a specific manufacturer’s product or tested system. We supply the test report, classification or listing accepted in your market for the product selected – it is confirmed per project, never assumed.