Fire-rated roller shutters

Large openings stay open for traffic and close automatically when the fire alarm or a fusible link triggers.

Steel slats
Curtain
Openings in fire walls
Use
Per tested shutter
Rating

見積もりを依頼

World Steel が鉄骨建築と一括で、または単体で供給 – 一つの注文、一つの出荷、一つのパートナー。

概要

Fire-rated roller shuttersについて

Fire shutters are tested to EN 1634-1 and classified under EN 13501-2 (usually E or EW; EI needs insulated curtains), to UL 10B / NFPA 80 in North America and to AS 1530.4 with AS 1905.2 in Australia.

Release is by fire-alarm signal, fusible link or both, with gravity or motorised fail-safe closing; the opening must be kept clear of obstructions.

The shutter, guides and head box are fixed to the steel framing of the opening, which must itself be fire-protected for the rating.

主なメリット

  • Closes large openings automatically
  • Fail-safe release on alarm or fusible link
  • Steel slats, guides and coil box
  • Tested with the wall type

World Steel · 外装材ハブ

鉄骨建築におけるFire-rated roller shuttersの活用

World Steel designs the steel framing around shutter openings and protects it for the same fire rating.

Product-specific test reports, classification reports and certificates are supplied for the product selected for each project – this page describes the product type, not a certified product.

  • 01構造と一体で仕様決定 – 厚さ、密度、表面材を屋根・外壁・耐火設計に合わせます。
  • 02数量は鉄骨、母屋、外装材と同じ 3D モデルから算出。
  • 03鉄骨パッケージとともに梱包・出荷 – 現場への納入スケジュールは一つです。

用途

Fire-rated roller shuttersの用途

  • Conveyor and loading openings in fire walls
  • Counters and service hatches
  • Warehouse compartment openings

技術データ

Fire-rated roller shutters – 技術特性

Typical properties and standards

特性単位値
Fire test—EN 1634-1 · UL 10B / NFPA 80 · AS 1530.4
Product standard—EN 13241 (industrial doors) · AS 1905.2 (fire-resistant shutters)
Classification—EN 13501-2 – E, EW, EI
Release—Fire alarm interface and / or fusible link, fail-safe closing

この市場向けにメーカーが公表している値です。ご注文前に必ず最新のデータシートと、プロジェクトに必要な認定をご確認ください。

FAQ

よくある質問

Does a fire shutter stop heat?

Most shutters are integrity-rated (E or EW); insulated (EI) shutters exist but are thicker – the code decides which class is needed.

Is this product certified?

Certification belongs to a specific manufacturer’s product or tested system. We supply the test report, classification or listing accepted in your market for the product selected – it is confirmed per project, never assumed.