Fire curtains · combined
Combined fire and smoke curtains
One barrier, two jobs: a fabric curtain classified for fire integrity and smoke leakage, deployed on alarm.
- Coated fire-resistant fabric
- Barrier
- E / EW + smoke
- Classes
- Fire alarm, fail-safe
- Activation
World Steel が鉄骨建築と一括で、または単体で供給 – 一つの注文、一つの出荷、一つのパートナー。
概要
Combined fire and smoke curtainsについて
Combined curtains are tested both as fire barriers (EN 1634-1, classified E or EW with smoke-leakage performance) and as smoke barriers where required (EN 12101-1).
They are chosen where an opening must hold back smoke early in a fire and flames later – for example lift lobbies and corridor openings.
As with all active barriers, commissioning, periodic testing and maintenance are part of compliance.
主なメリット
- Fire and smoke in one barrier
- Concealed until deployed
- Saves space compared with doors
- Alarm-activated, gravity fail-safe
World Steel · 外装材ハブ
鉄骨建築におけるCombined fire and smoke curtainsの活用
World Steel coordinates the head-box supports and opening framing with the steel structure.
Product-specific test reports, classification reports and certificates are supplied for the product selected for each project – this page describes the product type, not a certified product.
- 01構造と一体で仕様決定 – 厚さ、密度、表面材を屋根・外壁・耐火設計に合わせます。
- 02数量は鉄骨、母屋、外装材と同じ 3D モデルから算出。
- 03鉄骨パッケージとともに梱包・出荷 – 現場への納入スケジュールは一つです。
用途
Combined fire and smoke curtainsの用途
- Lift lobbies and corridors
- Openings between compartments
- Commercial and public buildings
技術データ
Combined fire and smoke curtains – 技術特性
Typical properties and standards
| 特性 | 単位 | 値 |
|---|---|---|
| Fire test | — | EN 1634-1 · UL 10D · AS 1530.4 |
| Smoke | — | EN 12101-1 · smoke leakage per classification |
| Design / installation | — | BS 8524-1 / -2 · manufacturer’s tested details |
この市場向けにメーカーが公表している値です。ご注文前に必ず最新のデータシートと、プロジェクトに必要な認定をご確認ください。
Shutters & curtains
関連製品
Fire shutters · openingsFire-rated roller shutters製品を見る →
Fire curtains · active barriersAutomatic fire curtains製品を見る →
Smoke curtains · smoke controlSmoke curtains製品を見る →← Fire shutters, fire curtains and smoke curtainsFire-Rated Building Systems – Panels, Doors, Glazing, Shutters and Curtains →
FAQ
よくある質問
When is a combined curtain better than two separate systems?
When one opening needs both functions and space is limited – the fire engineer confirms that the classified performance meets the strategy.
Is this product certified?
Certification belongs to a specific manufacturer’s product or tested system. We supply the test report, classification or listing accepted in your market for the product selected – it is confirmed per project, never assumed.