Fire curtains · combined
Combined fire and smoke curtains
One barrier, two jobs: a fabric curtain classified for fire integrity and smoke leakage, deployed on alarm.
- Coated fire-resistant fabric
- Barrier
- E / EW + smoke
- Classes
- Fire alarm, fail-safe
- Activation
Fornecido pela World Steel com seu edifício metálico ou separadamente – um pedido, um embarque, um parceiro.
Visão geral
Sobre Combined fire and smoke curtains
Combined curtains are tested both as fire barriers (EN 1634-1, classified E or EW with smoke-leakage performance) and as smoke barriers where required (EN 12101-1).
They are chosen where an opening must hold back smoke early in a fire and flames later – for example lift lobbies and corridor openings.
As with all active barriers, commissioning, periodic testing and maintenance are part of compliance.
Principais benefícios
- Fire and smoke in one barrier
- Concealed until deployed
- Saves space compared with doors
- Alarm-activated, gravity fail-safe
World Steel · central de envoltória da edificação
Como usamos Combined fire and smoke curtains em edifícios metálicos
World Steel coordinates the head-box supports and opening framing with the steel structure.
Product-specific test reports, classification reports and certificates are supplied for the product selected for each project – this page describes the product type, not a certified product.
- 01Especificado junto com a estrutura – espessura, densidade e revestimento compatíveis com o projeto da cobertura, das paredes e de proteção contra incêndio.
- 02Quantitativos extraídos do mesmo modelo 3D que o aço, as terças e o fechamento.
- 03Embalado e enviado com o pacote de aço – um único cronograma de entrega na obra.
Aplicações
Onde Combined fire and smoke curtains é utilizado
- Lift lobbies and corridors
- Openings between compartments
- Commercial and public buildings
Dados técnicos
Combined fire and smoke curtains – propriedades técnicas
Typical properties and standards
| Propriedade | Unidade | Valor |
|---|---|---|
| Fire test | — | EN 1634-1 · UL 10D · AS 1530.4 |
| Smoke | — | EN 12101-1 · smoke leakage per classification |
| Design / installation | — | BS 8524-1 / -2 · manufacturer’s tested details |
Valores conforme publicados pelo fabricante para este mercado. Sempre verifique a ficha técnica atual e as aprovações exigidas para seu projeto antes de fazer o pedido.
Shutters & curtains
Produtos relacionados
Fire shutters · openingsFire-rated roller shuttersVer produto →
Fire curtains · active barriersAutomatic fire curtainsVer produto →
Smoke curtains · smoke controlSmoke curtainsVer produto →← Fire shutters, fire curtains and smoke curtainsFire-Rated Building Systems – Panels, Doors, Glazing, Shutters and Curtains →
FAQ
Perguntas frequentes
When is a combined curtain better than two separate systems?
When one opening needs both functions and space is limited – the fire engineer confirms that the classified performance meets the strategy.
Is this product certified?
Certification belongs to a specific manufacturer’s product or tested system. We supply the test report, classification or listing accepted in your market for the product selected – it is confirmed per project, never assumed.
Um único parceiro para estrutura e envoltória
Envie-nos seus desenhos ou planilha de quantitativos – cotamos o aço, o isolamento, as placas e os forros em conjunto e os enviamos como um único pacote.