Fire curtains · combined
Combined fire and smoke curtains
One barrier, two jobs: a fabric curtain classified for fire integrity and smoke leakage, deployed on alarm.
- Coated fire-resistant fabric
- Barrier
- E / EW + smoke
- Classes
- Fire alarm, fail-safe
- Activation
Supplied by World Steel with your steel building or on its own – one order, one shipment, one partner.
Overview
About Combined fire and smoke curtains
Combined curtains are tested both as fire barriers (EN 1634-1, classified E or EW with smoke-leakage performance) and as smoke barriers where required (EN 12101-1).
They are chosen where an opening must hold back smoke early in a fire and flames later – for example lift lobbies and corridor openings.
As with all active barriers, commissioning, periodic testing and maintenance are part of compliance.
Key benefits
- Fire and smoke in one barrier
- Concealed until deployed
- Saves space compared with doors
- Alarm-activated, gravity fail-safe
World Steel · building envelope hub
How we use Combined fire and smoke curtains in steel buildings
World Steel coordinates the head-box supports and opening framing with the steel structure.
Product-specific test reports, classification reports and certificates are supplied for the product selected for each project – this page describes the product type, not a certified product.
- 01Specified with the structure – thickness, density and facing matched to the roof, wall and fire design.
- 02Quantities taken from the same 3D model as the steel, purlins and cladding.
- 03Packed and shipped with the steel package – one delivery schedule to site.
Applications
Where Combined fire and smoke curtains is used
- Lift lobbies and corridors
- Openings between compartments
- Commercial and public buildings
Technical data
Combined fire and smoke curtains – technical properties
Typical properties and standards
| Property | Unit | Value |
|---|---|---|
| Fire test | — | EN 1634-1 · UL 10D · AS 1530.4 |
| Smoke | — | EN 12101-1 · smoke leakage per classification |
| Design / installation | — | BS 8524-1 / -2 · manufacturer’s tested details |
Values as published by the manufacturer for this market. Always check the current data sheet and the approvals required for your project before ordering.
Shutters & curtains
Related products
Fire shutters · openingsFire-rated roller shuttersView product →
Fire curtains · active barriersAutomatic fire curtainsView product →
Smoke curtains · smoke controlSmoke curtainsView product →← Fire shutters, fire curtains and smoke curtainsFire-Rated Building Systems – Panels, Doors, Glazing, Shutters and Curtains →
FAQ
Frequently asked questions
When is a combined curtain better than two separate systems?
When one opening needs both functions and space is limited – the fire engineer confirms that the classified performance meets the strategy.
Is this product certified?
Certification belongs to a specific manufacturer’s product or tested system. We supply the test report, classification or listing accepted in your market for the product selected – it is confirmed per project, never assumed.
One partner for structure and envelope
Send us your drawings or bill of quantities – we quote the steel, insulation, boards and ceilings together and ship them as one package.