Fire curtains · combined
Combined fire and smoke curtains
One barrier, two jobs: a fabric curtain classified for fire integrity and smoke leakage, deployed on alarm.
- Coated fire-resistant fabric
- Barrier
- E / EW + smoke
- Classes
- Fire alarm, fail-safe
- Activation
World Steel이 철골 건축물과 함께 또는 단독으로 공급 – 하나의 주문, 하나의 선적, 하나의 파트너.
개요
Combined fire and smoke curtains 소개
Combined curtains are tested both as fire barriers (EN 1634-1, classified E or EW with smoke-leakage performance) and as smoke barriers where required (EN 12101-1).
They are chosen where an opening must hold back smoke early in a fire and flames later – for example lift lobbies and corridor openings.
As with all active barriers, commissioning, periodic testing and maintenance are part of compliance.
주요 장점
- Fire and smoke in one barrier
- Concealed until deployed
- Saves space compared with doors
- Alarm-activated, gravity fail-safe
World Steel · 건물 외피 허브
철골 건축물에서의 Combined fire and smoke curtains 활용 방식
World Steel coordinates the head-box supports and opening framing with the steel structure.
Product-specific test reports, classification reports and certificates are supplied for the product selected for each project – this page describes the product type, not a certified product.
- 01구조물과 함께 사양 결정 – 두께, 밀도, 면재를 지붕, 벽 및 내화 설계에 맞춥니다.
- 02철골, 퍼린, 외장재와 동일한 3D 모델에서 물량을 산출합니다.
- 03철골 패키지와 함께 포장·선적 – 현장까지 하나의 납품 일정.
용도
Combined fire and smoke curtains의 사용처
- Lift lobbies and corridors
- Openings between compartments
- Commercial and public buildings
기술 데이터
Combined fire and smoke curtains – 기술 특성
Typical properties and standards
| 특성 | 단위 | 값 |
|---|---|---|
| Fire test | — | EN 1634-1 · UL 10D · AS 1530.4 |
| Smoke | — | EN 12101-1 · smoke leakage per classification |
| Design / installation | — | BS 8524-1 / -2 · manufacturer’s tested details |
해당 시장용으로 제조사가 공개한 값입니다. 주문 전 항상 최신 데이터 시트와 프로젝트에 필요한 승인 사항을 확인하세요.
Shutters & curtains
관련 제품
Fire shutters · openingsFire-rated roller shutters제품 보기 →
Fire curtains · active barriersAutomatic fire curtains제품 보기 →
Smoke curtains · smoke controlSmoke curtains제품 보기 →← Fire shutters, fire curtains and smoke curtainsFire-Rated Building Systems – Panels, Doors, Glazing, Shutters and Curtains →
FAQ
자주 묻는 질문
When is a combined curtain better than two separate systems?
When one opening needs both functions and space is limited – the fire engineer confirms that the classified performance meets the strategy.
Is this product certified?
Certification belongs to a specific manufacturer’s product or tested system. We supply the test report, classification or listing accepted in your market for the product selected – it is confirmed per project, never assumed.
구조와 외피를 위한 하나의 파트너
도면 또는 물량 내역서를 보내주시면 철골, 단열재, 보드, 천장재를 함께 견적하여 하나의 패키지로 선적합니다.