建立信任,确保成功 客户门户 dang.victor@worldsteelgroup.com +84 902 881 833
World SteelBuilding trust, Assuring success
Combined fire and smoke curtains – illustration

产品图片:制造商(官方)。

Fire curtains · combined

Combined fire and smoke curtains

One barrier, two jobs: a fabric curtain classified for fire integrity and smoke leakage, deployed on alarm.

Coated fire-resistant fabric
Barrier
E / EW + smoke
Classes
Fire alarm, fail-safe
Activation

索取报价

由 World Steel 随您的钢结构建筑一并供应或单独供应 – 一份订单、一次发运、一个合作伙伴。

概览

关于Combined fire and smoke curtains

Combined curtains are tested both as fire barriers (EN 1634-1, classified E or EW with smoke-leakage performance) and as smoke barriers where required (EN 12101-1).

They are chosen where an opening must hold back smoke early in a fire and flames later – for example lift lobbies and corridor openings.

As with all active barriers, commissioning, periodic testing and maintenance are part of compliance.

主要优势

  • Fire and smoke in one barrier
  • Concealed until deployed
  • Saves space compared with doors
  • Alarm-activated, gravity fail-safe

World Steel · 建筑围护材料中心

我们如何在钢结构建筑中使用Combined fire and smoke curtains

World Steel coordinates the head-box supports and opening framing with the steel structure.

Product-specific test reports, classification reports and certificates are supplied for the product selected for each project – this page describes the product type, not a certified product.

  • 01与结构一同选型 – 厚度、密度和饰面与屋面、墙面及防火设计相匹配。
  • 02工程量取自与钢构件、檩条和围护板相同的 3D 模型。
  • 03与钢结构包一同包装发运 – 一份到场交货计划。

应用

Combined fire and smoke curtains的应用场合

  • Lift lobbies and corridors
  • Openings between compartments
  • Commercial and public buildings

技术数据

Combined fire and smoke curtains – 技术性能

Typical properties and standards

性能单位数值
Fire test—EN 1634-1 · UL 10D · AS 1530.4
Smoke—EN 12101-1 · smoke leakage per classification
Design / installation—BS 8524-1 / -2 · manufacturer’s tested details

数值为制造商针对该市场公布的数据。订货前请务必核对最新数据表及项目所需的认证。

FAQ

常见问题

When is a combined curtain better than two separate systems?

When one opening needs both functions and space is limited – the fire engineer confirms that the classified performance meets the strategy.

Is this product certified?

Certification belongs to a specific manufacturer’s product or tested system. We supply the test report, classification or listing accepted in your market for the product selected – it is confirmed per project, never assumed.

结构与围护,一个合作伙伴

发送图纸或工程量清单 – 我们为钢结构、保温材料、板材和吊顶统一报价,并作为一个包发运。