Fire-rated roller shutters

Large openings stay open for traffic and close automatically when the fire alarm or a fusible link triggers.

Steel slats
Curtain
Openings in fire walls
Use
Per tested shutter
Rating

索取报价

由 World Steel 随您的钢结构建筑一并供应或单独供应 – 一份订单、一次发运、一个合作伙伴。

概览

关于Fire-rated roller shutters

Fire shutters are tested to EN 1634-1 and classified under EN 13501-2 (usually E or EW; EI needs insulated curtains), to UL 10B / NFPA 80 in North America and to AS 1530.4 with AS 1905.2 in Australia.

Release is by fire-alarm signal, fusible link or both, with gravity or motorised fail-safe closing; the opening must be kept clear of obstructions.

The shutter, guides and head box are fixed to the steel framing of the opening, which must itself be fire-protected for the rating.

主要优势

  • Closes large openings automatically
  • Fail-safe release on alarm or fusible link
  • Steel slats, guides and coil box
  • Tested with the wall type

World Steel · 建筑围护材料中心

我们如何在钢结构建筑中使用Fire-rated roller shutters

World Steel designs the steel framing around shutter openings and protects it for the same fire rating.

Product-specific test reports, classification reports and certificates are supplied for the product selected for each project – this page describes the product type, not a certified product.

  • 01与结构一同选型 – 厚度、密度和饰面与屋面、墙面及防火设计相匹配。
  • 02工程量取自与钢构件、檩条和围护板相同的 3D 模型。
  • 03与钢结构包一同包装发运 – 一份到场交货计划。

应用

Fire-rated roller shutters的应用场合

  • Conveyor and loading openings in fire walls
  • Counters and service hatches
  • Warehouse compartment openings

技术数据

Fire-rated roller shutters – 技术性能

Typical properties and standards

性能单位数值
Fire test—EN 1634-1 · UL 10B / NFPA 80 · AS 1530.4
Product standard—EN 13241 (industrial doors) · AS 1905.2 (fire-resistant shutters)
Classification—EN 13501-2 – E, EW, EI
Release—Fire alarm interface and / or fusible link, fail-safe closing

数值为制造商针对该市场公布的数据。订货前请务必核对最新数据表及项目所需的认证。

FAQ

常见问题

Does a fire shutter stop heat?

Most shutters are integrity-rated (E or EW); insulated (EI) shutters exist but are thicker – the code decides which class is needed.

Is this product certified?

Certification belongs to a specific manufacturer’s product or tested system. We supply the test report, classification or listing accepted in your market for the product selected – it is confirmed per project, never assumed.

结构与围护,一个合作伙伴

发送图纸或工程量清单 – 我们为钢结构、保温材料、板材和吊顶统一报价,并作为一个包发运。

索取报价 +84 902 881 833