WS steel bar grating
Welded bar grating – the WS code, five standard meshes, materials, finishes and tolerances.
详情与表格 →
Flagship product · WS steel grating
WS welded bar grating from 20 × 3 to 150 × 8 mm in 30, 40 and 60 mm meshes – selected from published load and span tables, forge-welded, cut and banded to your layout, hot-dip galvanised and shipped with clips, treads and covers ready to install.

Grating is in almost every structure we build – platforms, walkways, stairs, mezzanines, trenches and drainage pits. That is why World Steel makes it as a product line of its own: a clear WS code system, standard meshes and panels, load tables for every size and a production line that forge-welds, cuts, bands and marks each panel to the layout.
You get the right bar for the load instead of a guess, panels that drop into place without site cutting, and one supplier for the grating, the platform steel, stair treads, handrails and covers – galvanised, packed by area and documented for export.
WS grating range
Every product has its own page with codes, tables, standards and ordering data.
Welded bar grating – the WS code, five standard meshes, materials, finishes and tolerances.
详情与表格 →Safe loads, deflections, weights and recommended spans for bars at 30, 40 and 60 mm.
详情与表格 →Deep bars and 8 × 8 mm cross bars for 5–7.5 kPa floors, forklifts and vehicles.
详情与表格 →Notched bars for wet, oily and outdoor floors – with load and deflection factors.
详情与表格 →Pickled and passivated stainless grating for food, chemical and marine areas.
详情与表格 →Welded or bolted treads with no nosing, checker-plate or abrasive anti-slip nosing.
详情与表格 →Trench covers for 100–600 mm trenches in classes pedestrian, T-2 to T-25.
详情与表格 →Pit covers with bedframes, 300 × 400 to 700 × 700 mm, T-2 to T-25.
详情与表格 →Saddle clips, hold-downs and M8 bolts – minimum four sets per panel.
详情与表格 →Where WS grating goes
One grating line, four families of use – each with its own tables and details.
2.5 – 5 kPa
Plant platforms, catwalks, mezzanines and roof walkways – panels cut around every column and pipe, with toe plates and clips.
T1 – T6
Treads with banded or holed end plates and checker or abrasive nosing, matched to the stair stringers and landings.
T-2 – T-25
GT, GU and GM covers with seat frames and bedframes, trial-fitted and supplied as sets.
panel by panel
Every panel marked to the layout, galvanised and palletised by area for container shipping.
应用领域
Boiler houses, turbine halls, cable trenches and coal or biomass handling.
Pipe-rack walkways, tank platforms, serrated and stainless floors.
Channel covers, filter galleries and stainless walkways over basins.
Conveyor walkways, transfer towers, heavy-duty floors and drainage.
Hygienic stainless platforms, wash-down areas and tank access.
Mezzanines, machine platforms, roads, car parks and drainage pits.
规范与合规
WS grating is designed and fabricated to the code named in the project specification. Key references:
摘要仅供参考——以项目技术规格书、所采用的规范版本及主管机构要求为准。
工程设计
WS-G325/30/100-S-G tells the whole story: 32 × 5 mm bearing bars at 30 mm, cross bars at 100 mm, serrated, hot-dip galvanised. Engineers, buyers and site teams read the same code on drawings, quotations, pallets and panel tags.
Choose plain (M) or serrated (S) bars, galvanised (G), paint coated (PP) or untreated (U), in SS400, A36, Q345 or stainless SUS304 / SUS316 – see the WS bar grating page.
工程设计
Every WS size has published safe uniform and concentrated loads, deflections and recommended spans for 2.5, 3, 4, 5 and 7.5 kPa. We select the lightest bar that carries your load over your span – and check wheel loads, serrated bars and deflection limits on top.
The full tables are on the load and span tables page; try the quick selector below for a first answer.
工程设计
Flat bars and twisted cross rods are forge-welded under heat and pressure at every intersection, straightened, cut to the shop drawing and banded around ends and openings. Each panel is checked for width, squareness, bar lean and bow, then marked.
Panels are hot-dip galvanised and palletised by area, so each platform is installed from one bundle – the same quality system that covers our structural steel, certified to ISO 3834-2.
工程设计
Saddle clips – top plate, hold-down and M8 bolt – fix panels to the steel without damaging the zinc; at least four sets per panel. Welding is used where a floor will never be lifted: a fillet at the first bearing bar of every corner, 20 mm long and 3 mm high.
Panels leave about 10 mm gaps, bearing bars always span between supports, and every clip set is packed with its panels – see clips and fasteners.
工程设计
WS-GT covers sit in cast-in angle seat frames, WS-GU covers on the edges of precast U-channels and WS-GM covers in pit bedframes. Classes run from pedestrian through T-2, T-6 and T-14 to T-20 and T-25 – defined by rear wheel loads from 8 to 100 kN.
Covers can be bolted down or hinged against theft; frames and covers are trial-fitted and supplied as sets – see trench covers and pit covers.
Quick selector
Choose the design load and the clear span between supports – the selector lists the WS gratings that reach it, lightest first, from the WS recommended-span tables.
| Bars at 30 mm (WS 30/…) | Bars at 40 mm (WS 40/…) | Bars at 60 mm (WS 60/50) | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 型号 | 2.5 | 3.0 | 4.0 | 5.0 | 7.5 | 2.5 | 3.0 | 4.0 | 5.0 | 7.5 | 2.5 | 3.0 | 4.0 | 5.0 | 7.5 | |
| WS-G203 | 20 × 3 mm | 1190 | 1060 | 1060 | – | – | 1110 | 980 | 980 | – | – | 1000 | 890 | 890 | – | – |
| WS-G253 | 25 × 3 mm | 1410 | 1350 | 1250 | – | – | 1310 | 1250 | 1170 | – | – | 1180 | 1130 | 1050 | – | – |
| WS-G323 | 32 × 3 mm | 1700 | 1620 | 1510 | – | – | 1580 | 1510 | 1400 | – | – | 1430 | 1350 | 1270 | – | – |
| WS-G205 | 20 × 5 mm | 1350 | 1290 | 1200 | – | – | 1260 | 1200 | 1120 | – | – | 1140 | 1090 | 1010 | – | – |
| WS-G403 | 40 × 3 mm | 2010 | 1920 | 1780 | – | – | 1870 | 1780 | 1660 | – | – | 1690 | 1610 | 1500 | – | – |
| WS-G255 | 25 × 5 mm | 1600 | 1530 | 1420 | 1350 | 1220 | 1490 | 1420 | 1320 | 1250 | 1130 | 1350 | 1290 | 1200 | 1130 | 1020 |
| WS-G325 | 32 × 5 mm | 1930 | 1840 | 1710 | 1620 | 1460 | 1790 | 1710 | 1590 | 1510 | 1360 | 1620 | 1550 | 1440 | 1360 | 1230 |
| WS-G405 | 40 × 5 mm | 2280 | 2180 | 2030 | 1920 | 1730 | 2120 | 2030 | 1890 | 1780 | 1610 | 1920 | 1830 | 1700 | 1610 | 1460 |
| WS-G455 | 45 × 5 mm | – | – | – | 2090 | 1890 | – | – | – | 1950 | 1760 | – | – | – | 1760 | 1590 |
| WS-G505 | 50 × 5 mm | – | – | – | 2270 | 2050 | – | – | – | 2110 | 1910 | – | – | – | 1910 | 1720 |
| WS-G555 | 55 × 5 mm | – | – | – | 2440 | 2200 | – | – | – | 2270 | 2050 | – | – | – | 2050 | 1850 |
| WS-G655 | 65 × 5 mm | – | – | – | 2760 | 2490 | – | – | – | 2570 | 2320 | – | – | – | 2320 | 2100 |
| WS-G755 | 75 × 5 mm | – | – | – | 3080 | 2780 | – | – | – | 2860 | 2590 | – | – | – | 2590 | 2340 |
| WS-G756 | 75 × 6 mm | – | – | – | 3220 | 2910 | – | – | – | 3000 | 2710 | – | – | – | 2710 | 2440 |
Indicative: carbon steel, single simply-supported panel, plain bars, uniform load. Wheel loads, serrated bars and deflection limits are checked by our engineers before production.
技术规格
流程
Your drawings or IFC model, loads and code.
WS code per area from the load and span tables.
Panels, openings, banding and marks for approval.
Forge-welded, cut, banded and inspected panel by panel.
Hot-dip galvanised, coating thickness recorded.
Palletised with clips, marked and shipped.
FAQ
Bearing bars 32 mm high × 5 mm thick at 30 mm centres, cross bars at 100 mm, serrated (S) bars and hot-dip galvanised (G) finish. M means plain bars, PP paint coated and U untreated.
Pedestrian walkways are usually designed for 3 kPa (4 kPa for crowded public areas). With bars at 30 mm, WS-G253 spans about 1350 mm and WS-G325 about 1840 mm at 3 kPa – the project designer confirms the load and deflection limit.
Both. Standard panels are 5800 mm long and 970–1003 mm wide; most projects order panels cut to the layout, banded around openings and marked to match the drawing.
Hot-dip galvanising after fabrication is our standard finish, with the coating thickness recorded per batch. Paint coated, duplex, untreated and stainless steel grating are also available.
Our GT, GU and GM covers are made in WS classes T-2 to T-25 defined by wheel load. Where a project specifies EN 124, AS 3996 or AASHTO, covers are designed to that standard and, where conformity by test is required, made to a tested design or load-tested as specified.
The layout or IFC model with supports and openings, the design load or WS code, mesh and finish, the fixing type and the destination. For covers, the trench or pit sizes and the load class.
交货条件 · Incoterms® 2020
World Steel 可报出厂价、船上交货价或运至贵方港口、工地的价格。出口包装、单证及自胡志明市的运输均属我们的服务。
比较全部 Incoterms® 2020 →Send the layout and loads – we return the WS selection, panel drawings and a delivered price, with treads, covers and clips in one package.