建立信任,确保成功 客户门户 dang.victor@worldsteelgroup.com +84 902 881 833
World SteelBuilding trust, Assuring success

WS steel grating & floor plate · Clips & fasteners

WS grating clips and fasteners

WS saddle clips (M and L types), hold-downs, M8 bolts and weld fixing details for installing steel grating – galvanised or stainless, supplied with every grating package.

美国澳大利亚 / 新西兰欧洲

索取报价 技术规格

  • Saddle clip: top plate + hold-down + M8 bolt
  • Type M and L clips for different flanges
  • Weld fixing details
  • Galvanised or stainless
  • Min. 4 clip sets per panel

Three ways to fix grating

Welded, clipped and bolted grating fixing
Welding, saddle clips and drilled fixing.
  • Welding – for floors that will never be removed, such as flooring around machines. Fillet weld at the first bearing bar of every corner, at least 20 mm long and 3 mm high; touch up the zinc after welding.
  • Saddle clips – a top plate, a hold-down that hooks under the beam flange and an M8 bolt. Quick to install, removable and no damage to the galvanising; suitable for all gratings.
  • Drilled fixing – a hole in the flange with clip plate, bolt and nut, where a hook-type clip cannot be used.

Rules for installation

  • Use at least four sets of saddle clips per panel – more on long spans, vibrating floors and heavy-duty panels.
  • Leave about 10 mm between panels and at walls; 15 mm or 5 mm edge gaps per detail.
  • Bearing bars always span between supports; check direction before fixing.
  • Use galvanised clips with galvanised grating and stainless clips with stainless grating.

各市场标准与要求

World Steel 设计、加工本产品及编制文件所依据的规范——以及各市场的主要几何与荷载要求。

美国

  • ANSI/NAAMM MBG 531Metal Bar Grating Manual
  • ASCE 7Minimum design loads (Table 4.3-1 floor live loads)
  • OSHA 29 CFR 1910 Subpart DWalking-working surfaces
  • AWS D1.1Structural welding code – steel
  • ASTM A123Zinc (hot-dip galvanized) coatings on iron and steel products
  • CSI 05 53 00Metal gratings (MasterFormat section)
Light manufacturing / light storage live load
125 psf (ASCE 7 Table 4.3-1)
Heavy manufacturing / heavy storage live load
250 psf (ASCE 7 Table 4.3-1)
Toeboard at open edges
≥ 3.5 in (90 mm) high (OSHA 1910.29(k))
全部United States标准 →

澳大利亚 / 新西兰

  • AS 1657-2018Fixed platforms, walkways, stairways and ladders
  • AS/NZS 1170.1Structural design actions – imposed actions
  • AS 4100Steel structures
  • AS/NZS 1554.1Structural steel welding
  • AS/NZS 4680Hot-dip galvanized coatings on fabricated ferrous articles
  • AS 4586Slip resistance classification of pedestrian surfaces
Walkway clear width
≥ 600 mm (AS 1657)
Toeboard
≥ 100 mm where required (AS 1657)
全部Australia & New Zealand标准 →

欧洲

  • DIN 24537-1Gratings as floor covering – steel gratings
  • RAL-GZ 638Gratings – quality assurance
  • EN ISO 14122-2Working platforms and walkways
  • EN 1991-1-1Imposed loads on buildings
  • EN ISO 1461Hot-dip galvanized coatings on fabricated articles
Walkway clear width
≥ 600 mm, preferably 800 mm (EN ISO 14122-2)
Toe-plate
≥ 100 mm high (EN ISO 14122-3)
全部Europe标准 →

摘要仅供参考——以项目技术规格书、所采用的规范版本及主管机构要求为准。

表面处理

表面处理标准 / 备注
Hot-dip galvanised (G)ASTM A123 · AS/NZS 4680 · EN ISO 1461
StainlessA2 / A4 for stainless grating

常见问题

How many clips does a panel need?

At least four sets per panel, more for long spans, vibration or heavy loads.

Clips or welding?

Clips are removable and protect the zinc coating; welding is for permanent floors that will never be lifted.

下一个项目

计划在海外建造钢结构?

请发送您的图纸或 IFC 模型——我们的报价团队将回复加工范围、工期及到岸价格。