نبني الثقة ونضمن النجاح بوابة العملاء dang.victor@worldsteelgroup.com +84 902 881 833
World SteelBuilding trust, Assuring success

WS steel grating & floor plate · Clips & fasteners

WS grating clips and fasteners

WS saddle clips (M and L types), hold-downs, M8 bolts and weld fixing details for installing steel grating – galvanised or stainless, supplied with every grating package.

الولايات المتحدةأستراليا / نيوزيلنداأوروبا

اطلب عرض سعر المواصفات

  • Saddle clip: top plate + hold-down + M8 bolt
  • Type M and L clips for different flanges
  • Weld fixing details
  • Galvanised or stainless
  • Min. 4 clip sets per panel

Three ways to fix grating

Welded, clipped and bolted grating fixing
Welding, saddle clips and drilled fixing.
  • Welding – for floors that will never be removed, such as flooring around machines. Fillet weld at the first bearing bar of every corner, at least 20 mm long and 3 mm high; touch up the zinc after welding.
  • Saddle clips – a top plate, a hold-down that hooks under the beam flange and an M8 bolt. Quick to install, removable and no damage to the galvanising; suitable for all gratings.
  • Drilled fixing – a hole in the flange with clip plate, bolt and nut, where a hook-type clip cannot be used.

Rules for installation

  • Use at least four sets of saddle clips per panel – more on long spans, vibrating floors and heavy-duty panels.
  • Leave about 10 mm between panels and at walls; 15 mm or 5 mm edge gaps per detail.
  • Bearing bars always span between supports; check direction before fixing.
  • Use galvanised clips with galvanised grating and stainless clips with stainless grating.

المعايير والمتطلبات حسب السوق

المعايير التي تصمم World Steel هذا المنتج وتصنّعه وتوثّقه وفقها – والمتطلبات الهندسية الرئيسية ومتطلبات الأحمال في كل سوق.

الولايات المتحدة

  • ANSI/NAAMM MBG 531Metal Bar Grating Manual
  • ASCE 7Minimum design loads (Table 4.3-1 floor live loads)
  • OSHA 29 CFR 1910 Subpart DWalking-working surfaces
  • AWS D1.1Structural welding code – steel
  • ASTM A123Zinc (hot-dip galvanized) coatings on iron and steel products
  • CSI 05 53 00Metal gratings (MasterFormat section)
Light manufacturing / light storage live load
125 psf (ASCE 7 Table 4.3-1)
Heavy manufacturing / heavy storage live load
250 psf (ASCE 7 Table 4.3-1)
Toeboard at open edges
≥ 3.5 in (90 mm) high (OSHA 1910.29(k))
جميع معايير United States →

أستراليا / نيوزيلندا

  • AS 1657-2018Fixed platforms, walkways, stairways and ladders
  • AS/NZS 1170.1Structural design actions – imposed actions
  • AS 4100Steel structures
  • AS/NZS 1554.1Structural steel welding
  • AS/NZS 4680Hot-dip galvanized coatings on fabricated ferrous articles
  • AS 4586Slip resistance classification of pedestrian surfaces
Walkway clear width
≥ 600 mm (AS 1657)
Toeboard
≥ 100 mm where required (AS 1657)
جميع معايير Australia & New Zealand →

أوروبا

  • DIN 24537-1Gratings as floor covering – steel gratings
  • RAL-GZ 638Gratings – quality assurance
  • EN ISO 14122-2Working platforms and walkways
  • EN 1991-1-1Imposed loads on buildings
  • EN ISO 1461Hot-dip galvanized coatings on fabricated articles
Walkway clear width
≥ 600 mm, preferably 800 mm (EN ISO 14122-2)
Toe-plate
≥ 100 mm high (EN ISO 14122-3)
جميع معايير Europe →

ملخص للاسترشاد فقط – تسري مواصفات المشروع وإصدار المعيار المعتمد والجهة المختصة.

التشطيبات

التشطيبالمعايير / ملاحظات
Hot-dip galvanised (G)ASTM A123 · AS/NZS 4680 · EN ISO 1461
StainlessA2 / A4 for stainless grating

الأسئلة المتكررة

How many clips does a panel need?

At least four sets per panel, more for long spans, vibration or heavy loads.

Clips or welding?

Clips are removable and protect the zinc coating; welding is for permanent floors that will never be lifted.

المشروع القادم

هل تخططون لمنشأة فولاذية في الخارج؟

أرسلوا إلينا مخططاتكم أو نموذج IFC – يرد فريق التسعير لدينا بنطاق التصنيع والجدول الزمني والسعر شاملاً التسليم.