structure
R – loadbearing capacity
The element keeps carrying its load for the classified time – the criterion for protected steel beams and columns.

Fire protection · Compartmentation
Fire protection of the steel frame keeps the building standing; compartmentation keeps fire and smoke where they start. World Steel selects fire-rated sandwich panels, doorsets, glazing, shutters and curtains tested for your market and coordinates them with the steel structure.

Large steel buildings are divided into fire compartments by fire-rated walls and floors. Every opening in those walls – doors, glazing, conveyor openings, service hatches – must be closed by a system tested for the same separation, and smoke must be held back long enough for escape.
Fire ratings belong to tested assemblies: a panel wall with its joints and fixings, a door with its frame, hardware and seals, a curtain with its head box and controls. World Steel selects the systems your code and fire engineer require and supplies the test and classification documents for the products chosen – nothing is assumed.
تشكيلة المنتجات
Product-type pages with standards and typical data – the manufacturer and tested system are confirmed per project.
Stone wool sandwich panels for walls, roofs, partitions and compartment walls of steel buildings.
Fire-rated panels · wallsStone wool sandwich wall panelsTwo coated steel skins bonded to a stone wool core, fixed to the girts of the steel frame – the external wall and its fire performance arrive as one product.Stone (mineral) wool, non-combustibleCoreExternal walls, fire wallsUseاعرض المنتج →
Fire-rated panels · roofsStone wool sandwich roof panelsA ribbed steel roof panel with a non-combustible stone wool core – fire, thermal and acoustic performance for portal-frame roofs.Stone wool, non-combustibleCoreRoofs of steel buildingsUseاعرض المنتج →
Fire-rated panels · interiorsFire-rated partition and ceiling panelsSelf-supporting stone wool panels that divide large steel buildings into fire compartments, rooms and enclosures – with fire-rated doors and penetration seals.Stone woolCorePartitions, ceilings, enclosuresUseاعرض المنتج →
Fire-rated panels · compartment wallsFire compartment wall systemsA fire wall must stay standing and intact while the building on one side burns – the panel, its fixings and the steel that holds it are designed as one system.Stone wool, higher densityCoreCompartment and boundary wallsUseاعرض المنتج →Steel and glass fire doorsets, glazed fire partitions and fire-rated access panels – tested as complete assemblies.
Fire-rated doors · steelFire-rated steel doorsetsA fire door is a tested assembly: leaf, frame, hinges, lock, closer, seals and glazing all count. World Steel supplies complete doorsets, not loose parts.Steel, insulated coreLeafCompartments, exits, plant roomsUseاعرض المنتج →
Fire-rated doors · glazedFire-rated glass doorsGlass doors that keep fire and smoke back while keeping the building open and light – the glass type decides how much heat passes through.Steel profilesFrameFire-resistant glass, E / EW / EIGlassاعرض المنتج →
Fire-rated glazing · partitionsFire-rated glazed partitionsFixed fire-resistant glazing in steel framing that separates fire compartments without closing them visually.Steel profilesFrameFire-resistant, E / EW / EIGlassاعرض المنتج →
Fire-rated doors · access panelsFire-rated access panelsSmall doors for big risks: every access opening in a fire-rated wall, ceiling or shaft needs its own tested closure.Steel frame and doorBodyWalls, ceilings, shaftsUseاعرض المنتج →Active barriers that close openings on fire alarm – roller shutters, fire curtains, smoke curtains and combined curtains.
Fire shutters · openingsFire-rated roller shuttersLarge openings stay open for traffic and close automatically when the fire alarm or a fusible link triggers.Steel slatsCurtainOpenings in fire wallsUseاعرض المنتج →
Fire curtains · active barriersAutomatic fire curtainsA fire-resistant fabric barrier hidden in a slim head box, deployed by gravity when the fire alarm triggers.Fire-resistant fabricBarrierFire alarm, gravity fail-safeActivationاعرض المنتج →
Smoke curtains · smoke controlSmoke curtainsSmoke kills before heat does – smoke curtains create reservoirs and keep escape routes clear for longer.Smoke-resistant fabricBarrierStatic or automaticTypesاعرض المنتج →
Fire curtains · combinedCombined fire and smoke curtainsOne barrier, two jobs: a fabric curtain classified for fire integrity and smoke leakage, deployed on alarm.Coated fire-resistant fabricBarrierE / EW + smokeClassesاعرض المنتج →Fire resistance classes
European classification under EN 13501-2 – other markets express the same ideas in hours or FRLs.
structure
The element keeps carrying its load for the classified time – the criterion for protected steel beams and columns.
flames and hot gases
No flames or hot gases pass through – the basic criterion for shutters, curtains and most glazing.
unexposed side stays cool
The temperature rise on the protected side stays limited – required for walls and doors on escape routes.
radiation · impact · smoke
W limits radiation (EW glazing), M adds mechanical impact for fire walls, S200 / Sa limit smoke leakage through doors.
المعايير والامتثال
Test and classification standards most often specified in our export markets.
ملخص للاسترشاد فقط – تسري مواصفات المشروع وإصدار المعيار المعتمد والجهة المختصة.

Supplied with the steel
Doors, shutters and curtains hang on steel – trimmers, head beams and posts that must stay in place for the same rating. World Steel details that framing in the Tekla model, protects it with intumescent coatings or boards, and seals every service penetration with tested firestop systems.
See the overview of comprehensive fire protection for steel buildings.
شروط التسليم · Incoterms® 2020
تقدّم World Steel الأسعار تسليم المصنع، أو تسليم ظهر السفينة، أو تسليم مينائكم أو موقعكم. التعبئة للتصدير والمستندات والشحن من مدينة هو تشي منه جزء من خدمتنا.
قارن جميع قواعد Incoterms® 2020 →متاح أيضاً حسب المشروع أو عند الطلب: EXW · FAS · DAP · DPU · DDP
FAQ
No. Non-combustibility is a reaction-to-fire property of a material. A fire-resistance rating (for example EI 60) belongs to a tested wall system with its thickness, joints, fixings and supports.
Sometimes, where the fire engineer and authority accept them. Most fire curtains are integrity-only (E or EW), so they are not equivalent to an insulated fire wall.
For the products selected: technical data sheets, safety data sheets, fire test or classification reports, certificates or listings valid in your market, installation instructions and – where applicable – the Declaration of Performance.
We select products with test evidence for the market of each project. A certificate or listing is never assumed to be valid in every market.
Send the fire strategy, compartment layout and required ratings – we propose tested systems with the steel package.