Fire insulation · ducts and services
Fire-resistant insulation blankets and duct wraps
Ducts that pass through fire compartments must keep fire and heat in – wrap systems make them fire-rated.
- Ducts, grease ducts, services
- Use
- Stone wool or fibre blanket, foil-faced
- Material
- Per tested wrap system
- Rating
Fornito da World Steel con il vostro edificio in acciaio o separatamente – un ordine, una spedizione, un partner.
Panoramica
Informazioni su Fire-resistant insulation blankets and duct wraps
Fire-resistant duct wraps are tested on the duct type and size they protect: EN 1366-1 for ventilation ducts (classified under EN 13501-3), UL 2221 / ASTM E2336 for grease duct enclosures and AS 1530.4 in Australia.
Layer count, overlaps, pins, bands and penetration details through walls and floors are defined by the tested system.
A non-combustible blanket alone does not make a duct fire-rated – the tested system does.
Vantaggi principali
- Fire-rates ductwork without builders’ work shafts
- Thin, light wrap systems
- Grease-duct versions for kitchens
- Tested penetration details
World Steel · hub per l'involucro edilizio
Come utilizziamo Fire-resistant insulation blankets and duct wraps negli edifici in acciaio
World Steel coordinates duct supports and penetrations with the steel structure and the fire-rated walls and floors.
Product-specific test reports, classification reports and certificates are supplied for the product selected for each project – this page describes the product type, not a certified product.
- 01Specificato insieme alla struttura – spessore, densità e rivestimento adeguati al progetto di copertura, pareti e antincendio.
- 02Quantità ricavate dallo stesso modello 3D di acciaio, arcarecci e rivestimenti.
- 03Imballato e spedito con il pacchetto acciaio – un unico programma di consegna in cantiere.
Applicazioni
Dove si usa Fire-resistant insulation blankets and duct wraps
- Ventilation and smoke extract ducts
- Kitchen grease ducts
- Cable and pipe enclosures
Dati tecnici
Fire-resistant insulation blankets and duct wraps – proprietà tecniche
Typical properties and standards
| Proprietà | Unità | Valore |
|---|---|---|
| Fire test | — | EN 1366-1 / EN 13501-3 · UL 2221 / ASTM E2336 · AS 1530.4 |
| Reaction to fire | — | EN 13501-1 · ASTM E84 · ASTM E136 |
| Installation | — | Per tested system – layers, pins, banding |
Valori pubblicati dal produttore per questo mercato. Prima dell'ordine verificate sempre la scheda tecnica aggiornata e le approvazioni richieste per il vostro progetto.
High-temperature insulation
Prodotti correlati
← High-temperature and fire insulationOther Insulation Materials – PU/PIR, EPS, XPS, PE Foam →
FAQ
Domande frequenti
Is a mineral wool blanket enough to fire-rate a duct?
Only within a tested wrap system for that duct type – the number of layers, fixings and penetration details matter.
Is this product certified?
Certification belongs to a specific manufacturer’s product or tested system. We supply the test report, classification or listing accepted in your market for the product selected – it is confirmed per project, never assumed.
Un unico partner per struttura e involucro
Inviateci i disegni o il computo metrico – quotiamo insieme acciaio, isolamento, lastre e controsoffitti e li spediamo in un unico pacchetto.