建立信任,确保成功 客户门户 dang.victor@worldsteelgroup.com +84 902 881 833
World SteelBuilding trust, Assuring success
Fire-resistant insulation blankets and duct wraps – illustration

产品图片:制造商(官方)。

Fire insulation · ducts and services

Fire-resistant insulation blankets and duct wraps

Ducts that pass through fire compartments must keep fire and heat in – wrap systems make them fire-rated.

Ducts, grease ducts, services
Use
Stone wool or fibre blanket, foil-faced
Material
Per tested wrap system
Rating

索取报价

由 World Steel 随您的钢结构建筑一并供应或单独供应 – 一份订单、一次发运、一个合作伙伴。

概览

关于Fire-resistant insulation blankets and duct wraps

Fire-resistant duct wraps are tested on the duct type and size they protect: EN 1366-1 for ventilation ducts (classified under EN 13501-3), UL 2221 / ASTM E2336 for grease duct enclosures and AS 1530.4 in Australia.

Layer count, overlaps, pins, bands and penetration details through walls and floors are defined by the tested system.

A non-combustible blanket alone does not make a duct fire-rated – the tested system does.

主要优势

  • Fire-rates ductwork without builders’ work shafts
  • Thin, light wrap systems
  • Grease-duct versions for kitchens
  • Tested penetration details

World Steel · 建筑围护材料中心

我们如何在钢结构建筑中使用Fire-resistant insulation blankets and duct wraps

World Steel coordinates duct supports and penetrations with the steel structure and the fire-rated walls and floors.

Product-specific test reports, classification reports and certificates are supplied for the product selected for each project – this page describes the product type, not a certified product.

  • 01与结构一同选型 – 厚度、密度和饰面与屋面、墙面及防火设计相匹配。
  • 02工程量取自与钢构件、檩条和围护板相同的 3D 模型。
  • 03与钢结构包一同包装发运 – 一份到场交货计划。

应用

Fire-resistant insulation blankets and duct wraps的应用场合

  • Ventilation and smoke extract ducts
  • Kitchen grease ducts
  • Cable and pipe enclosures

技术数据

Fire-resistant insulation blankets and duct wraps – 技术性能

Typical properties and standards

性能单位数值
Fire test—EN 1366-1 / EN 13501-3 · UL 2221 / ASTM E2336 · AS 1530.4
Reaction to fire—EN 13501-1 · ASTM E84 · ASTM E136
Installation—Per tested system – layers, pins, banding

数值为制造商针对该市场公布的数据。订货前请务必核对最新数据表及项目所需的认证。

FAQ

常见问题

Is a mineral wool blanket enough to fire-rate a duct?

Only within a tested wrap system for that duct type – the number of layers, fixings and penetration details matter.

Is this product certified?

Certification belongs to a specific manufacturer’s product or tested system. We supply the test report, classification or listing accepted in your market for the product selected – it is confirmed per project, never assumed.

结构与围护,一个合作伙伴

发送图纸或工程量清单 – 我们为钢结构、保温材料、板材和吊顶统一报价,并作为一个包发运。

索取报价 +84 902 881 833