High-temperature insulation
Ceramic and high-temperature fibre insulation
Insulation for heat far beyond building fires – furnaces, hot ducts and equipment in industrial plants.
- Process heat, equipment
- Use
- Blanket, board, paper, module
- Forms
- By classification temperature
- Grades
由 World Steel 随您的钢结构建筑一并供应或单独供应 – 一份订单、一次发运、一个合作伙伴。
概览
关于Ceramic and high-temperature fibre insulation
Ceramic (refractory) fibre and low-biopersistence alkaline-earth silicate (AES) fibres insulate at process temperatures well above building fire curves; grades are selected by classification temperature.
Refractory ceramic fibre is classified as a carcinogen (category 1B) under the EU CLP regulation, so AES or other low-biopersistence fibres are preferred where they meet the temperature.
These products protect equipment and processes – they are not a substitute for a tested fire-resistance system for structural steel.
主要优势
- Very high service temperatures
- Low heat storage, fast heat-up
- Flexible forms for complex shapes
- Low-biopersistence options
World Steel · 建筑围护材料中心
我们如何在钢结构建筑中使用Ceramic and high-temperature fibre insulation
World Steel supplies high-temperature insulation with plant and equipment structures and coordinates supports and cladding.
Product-specific test reports, classification reports and certificates are supplied for the product selected for each project – this page describes the product type, not a certified product.
- 01与结构一同选型 – 厚度、密度和饰面与屋面、墙面及防火设计相匹配。
- 02工程量取自与钢构件、檩条和围护板相同的 3D 模型。
- 03与钢结构包一同包装发运 – 一份到场交货计划。
应用
Ceramic and high-temperature fibre insulation的应用场合
- Furnace and kiln linings
- Hot ducts and flues
- Equipment and expansion-joint insulation
技术数据
Ceramic and high-temperature fibre insulation – 技术性能
Typical properties and standards
| 性能 | 单位 | 数值 |
|---|---|---|
| Classification temperature | °C | By grade – selected for the process temperature |
| Fibre types | — | Refractory ceramic fibre (RCF), AES / low-biopersistence fibres |
| Health | — | RCF: EU CLP carcinogen cat. 1B – handling controls; AES preferred where suitable |
| Standards | — | EN 1094-7 (test methods for blankets) · ASTM C892 (blankets) |
数值为制造商针对该市场公布的数据。订货前请务必核对最新数据表及项目所需的认证。
FAQ
常见问题
Can ceramic fibre protect structural steel in a building fire?
Only as part of a tested fire-resistance system. For structural steel use intumescents, boards or sprays with test evidence.
Is this product certified?
Certification belongs to a specific manufacturer’s product or tested system. We supply the test report, classification or listing accepted in your market for the product selected – it is confirmed per project, never assumed.