信頼を築き、成功を確かなものに クライアントポータル dang.victor@worldsteelgroup.com +84 902 881 833
World SteelBuilding trust, Assuring success
Fire-resistant insulation blankets and duct wraps – illustration

製品画像:メーカー(公式)。

Fire insulation · ducts and services

Fire-resistant insulation blankets and duct wraps

Ducts that pass through fire compartments must keep fire and heat in – wrap systems make them fire-rated.

Ducts, grease ducts, services
Use
Stone wool or fibre blanket, foil-faced
Material
Per tested wrap system
Rating

見積もりを依頼

World Steel が鉄骨建築と一括で、または単体で供給 – 一つの注文、一つの出荷、一つのパートナー。

概要

Fire-resistant insulation blankets and duct wrapsについて

Fire-resistant duct wraps are tested on the duct type and size they protect: EN 1366-1 for ventilation ducts (classified under EN 13501-3), UL 2221 / ASTM E2336 for grease duct enclosures and AS 1530.4 in Australia.

Layer count, overlaps, pins, bands and penetration details through walls and floors are defined by the tested system.

A non-combustible blanket alone does not make a duct fire-rated – the tested system does.

主なメリット

  • Fire-rates ductwork without builders’ work shafts
  • Thin, light wrap systems
  • Grease-duct versions for kitchens
  • Tested penetration details

World Steel · 外装材ハブ

鉄骨建築におけるFire-resistant insulation blankets and duct wrapsの活用

World Steel coordinates duct supports and penetrations with the steel structure and the fire-rated walls and floors.

Product-specific test reports, classification reports and certificates are supplied for the product selected for each project – this page describes the product type, not a certified product.

  • 01構造と一体で仕様決定 – 厚さ、密度、表面材を屋根・外壁・耐火設計に合わせます。
  • 02数量は鉄骨、母屋、外装材と同じ 3D モデルから算出。
  • 03鉄骨パッケージとともに梱包・出荷 – 現場への納入スケジュールは一つです。

用途

Fire-resistant insulation blankets and duct wrapsの用途

  • Ventilation and smoke extract ducts
  • Kitchen grease ducts
  • Cable and pipe enclosures

技術データ

Fire-resistant insulation blankets and duct wraps – 技術特性

Typical properties and standards

特性単位値
Fire test—EN 1366-1 / EN 13501-3 · UL 2221 / ASTM E2336 · AS 1530.4
Reaction to fire—EN 13501-1 · ASTM E84 · ASTM E136
Installation—Per tested system – layers, pins, banding

この市場向けにメーカーが公表している値です。ご注文前に必ず最新のデータシートと、プロジェクトに必要な認定をご確認ください。

FAQ

よくある質問

Is a mineral wool blanket enough to fire-rate a duct?

Only within a tested wrap system for that duct type – the number of layers, fixings and penetration details matter.

Is this product certified?

Certification belongs to a specific manufacturer’s product or tested system. We supply the test report, classification or listing accepted in your market for the product selected – it is confirmed per project, never assumed.

構造と外装を一つのパートナーで

図面または数量明細書をお送りください – 鉄骨、断熱材、ボード、天井材をまとめて見積り、一つのパッケージで出荷します。