Firestop · penetration and joint seals
Fire-rated linear joint seals
Gaps between walls, floors and façades move – their fire seals must move too.
- Penetrations and joints
- Use
- EI / F-T ratings per test
- Classification
- Tested with the wall or floor
- System
Fornito da World Steel con il vostro edificio in acciaio o separatamente – un ordine, una spedizione, un partner.
Panoramica
Informazioni su Fire-rated linear joint seals
Linear joint seals combine backing (often stone wool) with fire-rated sealants or sprays, sized for joint width and movement.
They are tested to EN 1366-4 (classified under EN 13501-2), UL 2079 / ASTM E1966 for joints and ASTM E2307 for perimeter fire barriers at curtain walls, and AS 1530.4.
Head-of-wall joints under steel decks need systems tested with the deck profile.
Vantaggi principali
- Accommodates building movement
- Seals head-of-wall and floor joints
- Perimeter barriers at curtain walls
- Tested for joint width and movement
World Steel · hub per l'involucro edilizio
Come utilizziamo Fire-rated linear joint seals negli edifici in acciaio
World Steel coordinates firestop systems with the fire-rated walls, floors and steel decks of the building package.
Product-specific test reports, classification reports and certificates are supplied for the product selected for each project – this page describes the product type, not a certified product.
- 01Specificato insieme alla struttura – spessore, densità e rivestimento adeguati al progetto di copertura, pareti e antincendio.
- 02Quantità ricavate dallo stesso modello 3D di acciaio, arcarecci e rivestimenti.
- 03Imballato e spedito con il pacchetto acciaio – un unico programma di consegna in cantiere.
Applicazioni
Dove si usa Fire-rated linear joint seals
- Head-of-wall joints under steel decks
- Expansion joints in floors and walls
- Curtain-wall slab edges
Dati tecnici
Fire-rated linear joint seals – proprietà tecniche
Typical properties and standards
| Proprietà | Unità | Valore |
|---|---|---|
| Fire test | — | EN 1366-4 · UL 2079 / ASTM E1966 · ASTM E2307 · AS 1530.4 |
| Movement | % | Per tested system |
Valori pubblicati dal produttore per questo mercato. Prima dell'ordine verificate sempre la scheda tecnica aggiornata e le approvazioni richieste per il vostro progetto.
Firestop systems
Prodotti correlati
Firestop · penetration and joint sealsFirestop mortarsVedi prodotto →
Firestop · penetration and joint sealsFirestop pillows and bagsVedi prodotto →
Firestop · penetration and joint sealsFirestop coatings for cables and battsVedi prodotto →← Firestop systems by typeFire Stopping and Penetration Seals →
FAQ
Domande frequenti
Can ordinary sealant fill a fire-rated joint?
No – only sealants and backing tested as a joint system for that width, movement and construction.
Is this product certified?
Certification belongs to a specific manufacturer’s product or tested system. We supply the test report, classification or listing accepted in your market for the product selected – it is confirmed per project, never assumed.
Un unico partner per struttura e involucro