Firestop · penetration and joint seals
Fire-rated linear joint seals
Gaps between walls, floors and façades move – their fire seals must move too.
- Penetrations and joints
- Use
- EI / F-T ratings per test
- Classification
- Tested with the wall or floor
- System
World Steel이 철골 건축물과 함께 또는 단독으로 공급 – 하나의 주문, 하나의 선적, 하나의 파트너.
개요
Fire-rated linear joint seals 소개
Linear joint seals combine backing (often stone wool) with fire-rated sealants or sprays, sized for joint width and movement.
They are tested to EN 1366-4 (classified under EN 13501-2), UL 2079 / ASTM E1966 for joints and ASTM E2307 for perimeter fire barriers at curtain walls, and AS 1530.4.
Head-of-wall joints under steel decks need systems tested with the deck profile.
주요 장점
- Accommodates building movement
- Seals head-of-wall and floor joints
- Perimeter barriers at curtain walls
- Tested for joint width and movement
World Steel · 건물 외피 허브
철골 건축물에서의 Fire-rated linear joint seals 활용 방식
World Steel coordinates firestop systems with the fire-rated walls, floors and steel decks of the building package.
Product-specific test reports, classification reports and certificates are supplied for the product selected for each project – this page describes the product type, not a certified product.
- 01구조물과 함께 사양 결정 – 두께, 밀도, 면재를 지붕, 벽 및 내화 설계에 맞춥니다.
- 02철골, 퍼린, 외장재와 동일한 3D 모델에서 물량을 산출합니다.
- 03철골 패키지와 함께 포장·선적 – 현장까지 하나의 납품 일정.
용도
Fire-rated linear joint seals의 사용처
- Head-of-wall joints under steel decks
- Expansion joints in floors and walls
- Curtain-wall slab edges
기술 데이터
Fire-rated linear joint seals – 기술 특성
Typical properties and standards
| 특성 | 단위 | 값 |
|---|---|---|
| Fire test | — | EN 1366-4 · UL 2079 / ASTM E1966 · ASTM E2307 · AS 1530.4 |
| Movement | % | Per tested system |
해당 시장용으로 제조사가 공개한 값입니다. 주문 전 항상 최신 데이터 시트와 프로젝트에 필요한 승인 사항을 확인하세요.
Firestop systems
관련 제품
Firestop · penetration and joint sealsFirestop mortars제품 보기 →
Firestop · penetration and joint sealsFirestop pillows and bags제품 보기 →
Firestop · penetration and joint sealsFirestop coatings for cables and batts제품 보기 →← Firestop systems by typeFire Stopping and Penetration Seals →
FAQ
자주 묻는 질문
Can ordinary sealant fill a fire-rated joint?
No – only sealants and backing tested as a joint system for that width, movement and construction.
Is this product certified?
Certification belongs to a specific manufacturer’s product or tested system. We supply the test report, classification or listing accepted in your market for the product selected – it is confirmed per project, never assumed.