Firestop · penetration and joint seals
Fire-rated linear joint seals
Gaps between walls, floors and façades move – their fire seals must move too.
- Penetrations and joints
- Use
- EI / F-T ratings per test
- Classification
- Tested with the wall or floor
- System
Fourni par World Steel avec votre bâtiment en acier ou séparément – une commande, une expédition, un partenaire.
Aperçu
À propos : Fire-rated linear joint seals
Linear joint seals combine backing (often stone wool) with fire-rated sealants or sprays, sized for joint width and movement.
They are tested to EN 1366-4 (classified under EN 13501-2), UL 2079 / ASTM E1966 for joints and ASTM E2307 for perimeter fire barriers at curtain walls, and AS 1530.4.
Head-of-wall joints under steel decks need systems tested with the deck profile.
Principaux avantages
- Accommodates building movement
- Seals head-of-wall and floor joints
- Perimeter barriers at curtain walls
- Tested for joint width and movement
World Steel · plateforme enveloppe du bâtiment
Comment nous utilisons Fire-rated linear joint seals dans les bâtiments en acier
World Steel coordinates firestop systems with the fire-rated walls, floors and steel decks of the building package.
Product-specific test reports, classification reports and certificates are supplied for the product selected for each project – this page describes the product type, not a certified product.
- 01Prescrit avec la structure – épaisseur, densité et parement adaptés à la conception de la toiture, des façades et de la sécurité incendie.
- 02Quantités issues de la même maquette 3D que l'acier, les pannes et le bardage.
- 03Emballé et expédié avec le lot acier – un seul planning de livraison sur chantier.
Applications
Où Fire-rated linear joint seals est utilisé
- Head-of-wall joints under steel decks
- Expansion joints in floors and walls
- Curtain-wall slab edges
Données techniques
Fire-rated linear joint seals – caractéristiques techniques
Typical properties and standards
| Caractéristique | Unité | Valeur |
|---|---|---|
| Fire test | — | EN 1366-4 · UL 2079 / ASTM E1966 · ASTM E2307 · AS 1530.4 |
| Movement | % | Per tested system |
Valeurs publiées par le fabricant pour ce marché. Vérifiez toujours la fiche technique en vigueur et les agréments requis pour votre projet avant de commander.
Firestop systems
Produits associés
Firestop · penetration and joint sealsFirestop mortarsVoir le produit →
Firestop · penetration and joint sealsFirestop pillows and bagsVoir le produit →
Firestop · penetration and joint sealsFirestop coatings for cables and battsVoir le produit →← Firestop systems by typeFire Stopping and Penetration Seals →
FAQ
Questions fréquentes
Can ordinary sealant fill a fire-rated joint?
No – only sealants and backing tested as a joint system for that width, movement and construction.
Is this product certified?
Certification belongs to a specific manufacturer’s product or tested system. We supply the test report, classification or listing accepted in your market for the product selected – it is confirmed per project, never assumed.
Un seul partenaire pour la structure et l'enveloppe
Envoyez-nous vos plans ou votre bordereau des quantités – nous chiffrons ensemble l'acier, l'isolation, les plaques et les plafonds et les expédions en un seul lot.