نبني الثقة ونضمن النجاح بوابتي dang.victor@worldsteelgroup.com +84 902 881 833
World SteelBuilding trust, Assuring success

Frame systems

Multi-span buildings

Multi-span PEB frames use interior columns to cover very wide buildings economically. Learn typical modules, slopes, column types, limits and applications.

آخر تحديث 3 دقيقة قراءة اعرض في النموذج ثلاثي الأبعاد →

Wide multi-span PEB with a continuous rafter supported on slender interior columns
Interior columns let one continuous rafter cover a very wide floor area.

How a multi-span frame works

A multi-span (MS) frame is a rigid frame whose rafter is supported at intermediate points by interior columns. The exterior columns and rafter are joined by moment connections as in a clear-span building, while the interior columns are usually slender members – pipe, square hollow section or small built-up I-sections – pinned at top and bottom so they carry mainly axial load. The rafter becomes a continuous beam over several supports, which dramatically reduces its bending moments and depth. Because the frame is lighter and the base thrust smaller, the foundations of the exterior columns are also reduced, although more individual footings are needed for the interior columns.

The roof is normally a single gable over the whole width, so there are no internal valley gutters: water drains to the two sidewalls. This is the main difference from a multi-gable building.

Frame type diagram including a multi-span frame with interior columns
Multi-span frames compared with other PEB frame types.

Typical dimensions

Typical multi-span PEB parameters
ParameterCommon rangeComment
Overall width40–150 m+Limited mainly by drainage length and thermal movement
Module (column spacing across width)15–30 mUnequal modules are possible to suit operations
Number of interior columns1–6 per frameNaming varies: by interior columns (MS-1, MS-2…) or by spans
Roof slope1:20 to 1:10Flatter slopes keep peak height reasonable on wide buildings
Eave height6–14 mPeak height = eave + slope × half width
Interior columnsPipe, SHS or built-up IUsually pinned top and bottom

When to choose multi-span

  • Very wide buildings – large warehouses, distribution centres and manufacturing halls – where interior columns can be placed between racking or production zones.
  • Projects where steel weight and foundation cost are critical: shorter rafter spans mean lighter frames and smaller base thrust.
  • Buildings where a single roof plane without valley gutters is preferred for watertightness.

The interior column grid should be coordinated with racking layouts, aisles, dock doors and fire-sprinkler mains at concept stage – moving a column line later changes the whole frame design. Column positions also influence fire-sprinkler layouts, lighting and the location of internal partitions, so a coordinated grid saves rework across several trades.

Variants: one, two and three interior columns

Multi-span frames are usually described by the number of interior columns per frame. The most common configurations are summarised below; the width ranges are typical, not limits, and depend on loads and the module chosen.

Typical multi-span configurations
ConfigurationModules across widthTypical overall widthTypical use
One interior column2About 24–60 mMedium warehouses and factories where a single central column line is acceptable
Two interior columns3About 36–90 mDistribution centres, production halls with a central aisle
Three interior columns4About 48–120 mLarge logistics buildings; modules often aligned with racking blocks
Four or more5+Over 100 mVery large footprints; transverse expansion joints often needed
  • Unequal modules are common: a wider central module for a production line with narrower side modules for storage.
  • Omitting interior columns in selected frames is possible with jack beams that carry the rafter over the missing column.
  • Rigid interior columns – built-up I-sections moment-connected to the rafter – are used when drift, cranes or mezzanines require more stiffness than the exterior columns can give alone.
  • For very wide buildings with extremely low slopes, the space-saver variant keeps the peak height down.

Design considerations and limits

  • Lateral stability. With pinned interior columns, the exterior moment-connected columns and rafter provide all transverse stiffness. On very wide buildings, some interior columns may be made rigid to control drift.
  • Drainage. All roof water runs to the sidewalls; on wide roofs the long run increases water depth on the sheeting and gutter sizes. Standing seam roofs with continuous sheets are often specified.
  • Thermal movement. Wide frames expand across the building; slotted connections or transverse expansion joints may be required.
  • Cranes. Cranes can run in individual modules, with runway beams supported on brackets on interior and exterior columns – see crane buildings.
  • Foundations. Interior columns introduce more footings but each carries a smaller load.

Interior columns in forklift areas need impact protection. Specify bollards or concrete pedestals early so base plate elevations are set correctly.

Multi-span frames from World Steel

World Steel optimises multi-span frames by testing module widths and interior column positions during concept design, then fabricates continuous rafters, exterior tapered columns and interior pipe or built-up columns as one primary frame package. The anatomy of the frame is shown in anatomy of a PEB.

المعايير حسب المنطقة

المنطقةالرمزالنطاق
United States AISC 360-22Frame stability and member design
Canada CSA S16-19Design of steel structures
Australia / NZ AS 4100:2020Steel structures
Europe EN 1993-1-1Eurocode 3 – general rules

الأسئلة المتكررة

How wide can a multi-span PEB be?

Widths of 100–150 m and more are achieved with several interior columns. Practical limits come from roof drainage length, thermal movement and peak height rather than from the frame itself.

Why are interior columns usually pinned?

Pinned interior columns carry mainly axial load, so they can be slender pipes or hollow sections with small foundations. Lateral stiffness comes from the moment-connected exterior frame.

What is the difference between multi-span and multi-gable?

A multi-span building has one continuous roof over interior columns. A multi-gable building has several gable roofs side by side with valley gutters between them.

Can an interior column be left out in some frames?

Yes. A jack beam spanning between the adjacent interior columns can support the rafter where a column is omitted, creating a wider column-free bay for a dock area or production line. The frames on either side are designed for the extra load.

المشروع القادم

هل تخططون لمنشأة فولاذية في الخارج؟

أرسلوا إلينا مخططاتكم أو نموذج IFC – يرد فريق التسعير لدينا بنطاق التصنيع والجدول الزمني والسعر شاملاً التسليم.