Fire-rated doors · glazed
Fire-rated glass doors
Glass doors that keep fire and smoke back while keeping the building open and light – the glass type decides how much heat passes through.
- Steel profiles
- Frame
- Fire-resistant glass, E / EW / EI
- Glass
- Per tested doorset
- Rating
Suministrado por World Steel con su edificio de acero o por separado – un pedido, un envío, un socio.
Resumen
Acerca de Fire-rated glass doors
Fire-resistant glass is classified by what it stops: E (integrity – flames and hot gases), EW (integrity plus limited radiation) or EI (integrity plus insulation – the protected face stays cool). The classification applies to the glass, frame and hardware tested together.
Glazed doors are tested to EN 1634-1 and classified under EN 13501-2; in North America fire-protective and fire-resistive glazing and doors follow UL 10C, UL 9 and ASTM E119 depending on the use.
Fire-resistant glass must also meet safety-glazing requirements for impact where people can collide with it.
Ventajas principales
- Daylight and visibility in fire compartments
- E, EW or EI classes to suit the code
- Steel frames matched to the wall
- Single, double and sidelight assemblies
World Steel · centro de envolvente del edificio
Cómo utilizamos Fire-rated glass doors en edificios de acero
World Steel coordinates glazed doorsets with the steel framing of the opening and the adjacent fire-rated walls.
Product-specific test reports, classification reports and certificates are supplied for the product selected for each project – this page describes the product type, not a certified product.
- 01Especificado junto con la estructura – espesor, densidad y revestimiento adaptados al diseño de cubierta, fachada y protección contra incendios.
- 02Cantidades obtenidas del mismo modelo 3D que el acero, las correas y el cerramiento.
- 03Embalado y enviado con el paquete de acero – un solo programa de entrega a obra.
Aplicaciones
Dónde se utiliza Fire-rated glass doors
- Lobbies and stair enclosures
- Office and corridor fire separations
- Shopping-centre and public building fronts
Datos técnicos
Fire-rated glass doors – propiedades técnicas
Typical properties and standards
| Propiedad | Unidad | Valor |
|---|---|---|
| Fire test | — | EN 1634-1 · UL 10C · ASTM E119 (fire-resistive glazing) · AS 1530.4 |
| Classification | — | EN 13501-2 – E, EW, EI |
| Safety glazing | — | EN 12600 · ANSI Z97.1 / CPSC 16 CFR 1201 · AS 1288 |
| Installation | — | Per the tested system – frame fixings and glazing seals |
Valores publicados por el fabricante para este mercado. Consulte siempre la ficha técnica vigente y las homologaciones requeridas para su proyecto antes de hacer el pedido.
Fire doors & glazing
Productos relacionados
Fire-rated doors · steelFire-rated steel doorsetsVer producto →
Fire-rated glazing · partitionsFire-rated glazed partitionsVer producto →
Fire-rated doors · access panelsFire-rated access panelsVer producto →← Fire-rated doors and glazingFire-Rated Building Systems – Panels, Doors, Glazing, Shutters and Curtains →
FAQ
Preguntas frecuentes
What is the difference between E, EW and EI glass?
E stops flames and hot gases, EW also limits heat radiation, EI also insulates so the unexposed side stays cool – which one is needed depends on the code and the use of the space.
Is this product certified?
Certification belongs to a specific manufacturer’s product or tested system. We supply the test report, classification or listing accepted in your market for the product selected – it is confirmed per project, never assumed.
Un solo socio para estructura y envolvente
Envíenos sus planos o su listado de cantidades – cotizamos juntos el acero, el aislamiento, las placas y los cielorrasos y los enviamos en un solo paquete.
