建立信任,确保成功 客户门户 dang.victor@worldsteelgroup.com +84 902 881 833
World SteelBuilding trust, Assuring success
Fire-rated glass doors – illustration

产品图片:制造商(官方)。

Fire-rated doors · glazed

Fire-rated glass doors

Glass doors that keep fire and smoke back while keeping the building open and light – the glass type decides how much heat passes through.

Steel profiles
Frame
Fire-resistant glass, E / EW / EI
Glass
Per tested doorset
Rating

索取报价

由 World Steel 随您的钢结构建筑一并供应或单独供应 – 一份订单、一次发运、一个合作伙伴。

概览

关于Fire-rated glass doors

Fire-resistant glass is classified by what it stops: E (integrity – flames and hot gases), EW (integrity plus limited radiation) or EI (integrity plus insulation – the protected face stays cool). The classification applies to the glass, frame and hardware tested together.

Glazed doors are tested to EN 1634-1 and classified under EN 13501-2; in North America fire-protective and fire-resistive glazing and doors follow UL 10C, UL 9 and ASTM E119 depending on the use.

Fire-resistant glass must also meet safety-glazing requirements for impact where people can collide with it.

主要优势

  • Daylight and visibility in fire compartments
  • E, EW or EI classes to suit the code
  • Steel frames matched to the wall
  • Single, double and sidelight assemblies

World Steel · 建筑围护材料中心

我们如何在钢结构建筑中使用Fire-rated glass doors

World Steel coordinates glazed doorsets with the steel framing of the opening and the adjacent fire-rated walls.

Product-specific test reports, classification reports and certificates are supplied for the product selected for each project – this page describes the product type, not a certified product.

  • 01与结构一同选型 – 厚度、密度和饰面与屋面、墙面及防火设计相匹配。
  • 02工程量取自与钢构件、檩条和围护板相同的 3D 模型。
  • 03与钢结构包一同包装发运 – 一份到场交货计划。

应用

Fire-rated glass doors的应用场合

  • Lobbies and stair enclosures
  • Office and corridor fire separations
  • Shopping-centre and public building fronts

技术数据

Fire-rated glass doors – 技术性能

Typical properties and standards

性能单位数值
Fire test—EN 1634-1 · UL 10C · ASTM E119 (fire-resistive glazing) · AS 1530.4
Classification—EN 13501-2 – E, EW, EI
Safety glazing—EN 12600 · ANSI Z97.1 / CPSC 16 CFR 1201 · AS 1288
Installation—Per the tested system – frame fixings and glazing seals

数值为制造商针对该市场公布的数据。订货前请务必核对最新数据表及项目所需的认证。

FAQ

常见问题

What is the difference between E, EW and EI glass?

E stops flames and hot gases, EW also limits heat radiation, EI also insulates so the unexposed side stays cool – which one is needed depends on the code and the use of the space.

Is this product certified?

Certification belongs to a specific manufacturer’s product or tested system. We supply the test report, classification or listing accepted in your market for the product selected – it is confirmed per project, never assumed.

结构与围护,一个合作伙伴

发送图纸或工程量清单 – 我们为钢结构、保温材料、板材和吊顶统一报价,并作为一个包发运。

索取报价 +84 902 881 833