Fire-rated doors · glazed
Fire-rated glass doors
Glass doors that keep fire and smoke back while keeping the building open and light – the glass type decides how much heat passes through.
- Steel profiles
- Frame
- Fire-resistant glass, E / EW / EI
- Glass
- Per tested doorset
- Rating
World Steel이 철골 건축물과 함께 또는 단독으로 공급 – 하나의 주문, 하나의 선적, 하나의 파트너.
개요
Fire-rated glass doors 소개
Fire-resistant glass is classified by what it stops: E (integrity – flames and hot gases), EW (integrity plus limited radiation) or EI (integrity plus insulation – the protected face stays cool). The classification applies to the glass, frame and hardware tested together.
Glazed doors are tested to EN 1634-1 and classified under EN 13501-2; in North America fire-protective and fire-resistive glazing and doors follow UL 10C, UL 9 and ASTM E119 depending on the use.
Fire-resistant glass must also meet safety-glazing requirements for impact where people can collide with it.
주요 장점
- Daylight and visibility in fire compartments
- E, EW or EI classes to suit the code
- Steel frames matched to the wall
- Single, double and sidelight assemblies
World Steel · 건물 외피 허브
철골 건축물에서의 Fire-rated glass doors 활용 방식
World Steel coordinates glazed doorsets with the steel framing of the opening and the adjacent fire-rated walls.
Product-specific test reports, classification reports and certificates are supplied for the product selected for each project – this page describes the product type, not a certified product.
- 01구조물과 함께 사양 결정 – 두께, 밀도, 면재를 지붕, 벽 및 내화 설계에 맞춥니다.
- 02철골, 퍼린, 외장재와 동일한 3D 모델에서 물량을 산출합니다.
- 03철골 패키지와 함께 포장·선적 – 현장까지 하나의 납품 일정.
용도
Fire-rated glass doors의 사용처
- Lobbies and stair enclosures
- Office and corridor fire separations
- Shopping-centre and public building fronts
기술 데이터
Fire-rated glass doors – 기술 특성
Typical properties and standards
| 특성 | 단위 | 값 |
|---|---|---|
| Fire test | — | EN 1634-1 · UL 10C · ASTM E119 (fire-resistive glazing) · AS 1530.4 |
| Classification | — | EN 13501-2 – E, EW, EI |
| Safety glazing | — | EN 12600 · ANSI Z97.1 / CPSC 16 CFR 1201 · AS 1288 |
| Installation | — | Per the tested system – frame fixings and glazing seals |
해당 시장용으로 제조사가 공개한 값입니다. 주문 전 항상 최신 데이터 시트와 프로젝트에 필요한 승인 사항을 확인하세요.
Fire doors & glazing
관련 제품
Fire-rated doors · steelFire-rated steel doorsets제품 보기 →
Fire-rated glazing · partitionsFire-rated glazed partitions제품 보기 →
Fire-rated doors · access panelsFire-rated access panels제품 보기 →← Fire-rated doors and glazingFire-Rated Building Systems – Panels, Doors, Glazing, Shutters and Curtains →
FAQ
자주 묻는 질문
What is the difference between E, EW and EI glass?
E stops flames and hot gases, EW also limits heat radiation, EI also insulates so the unexposed side stays cool – which one is needed depends on the code and the use of the space.
Is this product certified?
Certification belongs to a specific manufacturer’s product or tested system. We supply the test report, classification or listing accepted in your market for the product selected – it is confirmed per project, never assumed.
구조와 외피를 위한 하나의 파트너
도면 또는 물량 내역서를 보내주시면 철골, 단열재, 보드, 천장재를 함께 견적하여 하나의 패키지로 선적합니다.